Mitsubishi · PLC Power Supply Unit
R63P is a Mitsubishi power supply with Output voltage 5 VDC; Output current 6.5 A; Efficiency >=90%. It is used in DIN-rail control cabinets, sensor and relay supplies, backplane bus power where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Output voltage5 VDC
-
Output current6.5 A
-
Efficiency>=90%
-
Input voltage range85...264 V AC
Specifications
| Electrical |
| Supply voltage |
100...240 V AC |
| Input voltage range |
85...264 V AC |
| Output voltage |
5 VDC |
| Output current |
6.5 A |
| Efficiency |
>=90% |
| Mechanical |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Mitsubishi PLC Power Supply Unit specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Mitsubishi PLC Power Supply Unit variants |
| Catalog number |
Output current |
Output voltage |
Efficiency |
|
R63P (this page) |
6.5 A |
5 VDC |
>=90% |
| R61P |
6.5 A |
5 VDC |
>=90% |
| R62P |
3.5 A |
5 VDC |
>=90% |
| R64P |
9 A |
5 VDC |
>=90% |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The R63P is the device-level element in a Mitsubishi power supply installation. It receives the field signals and control supply listed above — 100...240 V AC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in DIN-rail control cabinets, sensor and relay supplies, backplane bus power, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Mitsubishi R63P
Mitsubishi R63P — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number R63P; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Output voltage: 5 VDC — Check this value against the nameplate of the installed unit before ordering.
- Output current: 6.5 A — Match it to the existing panel and upstream protection.
- Efficiency: >=90% — Record it with the other nameplate data when sourcing a replacement.
- Mounting: 35 mm DIN rail (IEC 60715) — Confirm the revision of the installed unit before a like-for-like replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about R63P
Q.Before ordering R63P, which certifications entry should be checked?
The certifications entry quoted above is CE, UL, cULus. Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the input voltage range data for R63P?
It is listed in the specification table for Mitsubishi R63P as 85...264 V AC. Compare it with the nameplate of the installed unit before ordering.
Q.For R63P, what does the specification table state about supply voltage?
The specification table lists supply voltage = 100...240 V AC for Mitsubishi R63P. Confirm this figure against the unit currently in the panel.
Q.What should I include in an enquiry for R63P?
Send the full catalog number R63P, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Mitsubishi R63P.
Q.Can the R63P replace the unit currently installed in my panel?
Compare catalog number R63P and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.