Mitsubishi · FR-D700
FRD720S025SCEC is a Mitsubishi variable-frequency drive with Overload capacity 150 % for 60 s (IEC 61800-2); Enclosure rating IP20 (IEC 60529); Frequency 50/60 Hz (IEC 61800-2). It is used in pump sets, conveyor belts, fan and compressor drives where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Overload capacity150 % for 60 s (IEC 61800-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Frequency50/60 Hz (IEC 61800-2)
-
Supply voltage1-phase 200...240 V / 3-phase 380...480 V AC
Specifications
| Electrical |
| Supply voltage |
1-phase 200...240 V / 3-phase 380...480 V AC |
| Input voltage range |
200-240 VAC |
| Output current |
2.5 A |
| Frequency |
50/60 Hz (IEC 61800-2) |
| Control method |
V/f, sensorless vector (IEC 61800-2) |
| Overload capacity |
150 % for 60 s (IEC 61800-2) |
| Mechanical |
| Mounting |
35 mm DIN rail or screw |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-10...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Mitsubishi FR-D700 specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Mitsubishi FR-D700 variants |
| Catalog number |
Overload capacity |
Frequency |
|
FRD720S025SCEC (this page) |
150 % for 60 s (IEC 61800-2) |
50/60 Hz (IEC 61800-2) |
| FRD720S008SCEC |
150 % for 60 s (IEC 61800-2) |
50/60 Hz (IEC 61800-2) |
| FRD720S014SCEC |
150 % for 60 s (IEC 61800-2) |
50/60 Hz (IEC 61800-2) |
| FRD720S070SCEC |
150 % for 60 s (IEC 61800-2) |
50/60 Hz (IEC 61800-2) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The FRD720S025SCEC is the device-level element in a Mitsubishi variable-frequency drive installation. It receives the field signals and control supply listed above — 1-phase 200...240 V / 3-phase 380...480 V AC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in pump sets, conveyor belts, fan and compressor drives, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail or screw support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Mitsubishi FRD720S025SCEC
Mitsubishi FRD720S025SCEC — Variable frequency drive for motor speed and torque control in pumps, fans, conveyors and general industrial machinery. The figures below are taken from the specification table on this page for catalog number FRD720S025SCEC; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Certifications: CE, UL, cULus — Use it as the reference when cross-checking a current-production equivalent.
- Overload capacity: 150 % for 60 s (IEC 61800-2) — Verify it in the project documentation before confirming the order.
- Supply voltage: 1-phase 200...240 V / 3-phase 380...480 V AC — Check this value against the nameplate of the installed unit before ordering.
- Operating temperature: -10...+60 °C (IEC 60068-2-1) — Match it to the existing panel and upstream protection.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about FRD720S025SCEC
Q.For FRD720S025SCEC, what does the specification table state about frequency?
The specification table lists frequency = 50/60 Hz (IEC 61800-2) for Mitsubishi FRD720S025SCEC. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under input voltage range for catalog number FRD720S025SCEC?
For FRD720S025SCEC, input voltage range is given as 200-240 VAC. Check the revision of the installed unit if the catalog number has been superseded.
Q.Before ordering FRD720S025SCEC, which operating temperature entry should be checked?
The operating temperature entry quoted above is -10...+60 °C (IEC 60068-2-1). Compare it with the nameplate of the installed unit before ordering.
Q.How do I confirm compatibility of FRD720S025SCEC before ordering?
Match the catalog number FRD720S025SCEC and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the FRD720S025SCEC replace the unit currently installed in my panel?
Compare catalog number FRD720S025SCEC and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.