KN5100 is an IFM circuit breaker with Rated operational voltage <= 440 V AC; Breaking capacity Icu/Ics yes; Supply voltage 10...30 V DC (IEC 60947-5-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Rated operational voltage<= 440 V AC
  • Breaking capacity Icu/Icsyes
  • Supply voltage10...30 V DC (IEC 60947-5-2)
  • Enclosure ratingIP20 (IEC 60529)

Specifications

Electrical
Rated operational voltage <= 440 V AC
Breaking capacity Icu/Ics yes
Supply voltage 10...30 V DC (IEC 60947-5-2)
Frequency 5
Overload capacity yes
Mechanical
Dimensions (H x W x D) M30 x 1.5 / L = 100
Mounting flush mountable
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature -25...+60 °C
Certifications CE, cULus

Values follow the IFM circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

IFM circuit breaker variants
Catalog number Breaking capacity Icu/Ics Rated operational voltage
KN5100 (this page) yes <= 440 V AC
KN5101 yes <= 440 V AC
KN5102 yes <= 440 V AC
KN5104 yes <= 440 V AC

Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.

Where it sits in the control system

The KN5100 is the device-level element in an IFM circuit breaker installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the <= 440 V AC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides flush mountable support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for IFM KN5100

IFM KN5100 Capacitive Sensor. See the manufacturer product information for this catalog number.

  • Frequency: 5 — Verify it in the project documentation before confirming the order.
  • Breaking capacity Icu/Ics: yes — Check this value against the nameplate of the installed unit before ordering.
  • Overload capacity: yes — Match it to the existing panel and upstream protection.
  • Supply voltage: 10...30 V DC (IEC 60947-5-2) — Record it with the other nameplate data when sourcing a replacement.

Cross-check the ratings above with the installed device before confirming the order.

Common questions about KN5100

Q.Before ordering KN5100, which operating temperature entry should be checked?

The operating temperature entry quoted above is -25...+60 °C. Confirm this figure against the unit currently in the panel.

Q.Where can I find the mounting data for KN5100?

It is listed in the specification table for IFM KN5100 as flush mountable. Use the value as the reference when sourcing a current-production equivalent.

Q.For KN5100, what does the specification table state about certifications?

The specification table lists certifications = CE, cULus for IFM KN5100. Check the revision of the installed unit if the catalog number has been superseded.

Q.What should I include in an enquiry for KN5100?

Send the full catalog number KN5100, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for IFM KN5100.

Q.How do I confirm compatibility of KN5100 before ordering?

Match the catalog number KN5100 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!