IFM · circuit breaker

KG5006 is an IFM circuit breaker with Rated operational voltage <= 440 V AC; Breaking capacity Icu/Ics yes; Supply voltage 10...30 V DC (IEC 60947-5-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Rated operational voltage<= 440 V AC
  • Breaking capacity Icu/Icsyes
  • Supply voltage10...30 V DC (IEC 60947-5-2)
  • Enclosure ratingIP20 (IEC 60529)

Specifications

Electrical
Rated operational voltage <= 440 V AC
Breaking capacity Icu/Ics yes
Supply voltage 10...30 V DC (IEC 60947-5-2)
Frequency 50
Overload capacity yes
Mechanical
Dimensions (H x W x D) M18 x 1 / L = 85
Mounting non-flush mountable
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature -25...+60 °C
Certifications CE, cULus

Values follow the IFM circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

IFM circuit breaker variants
Catalog number Breaking capacity Icu/Ics Rated operational voltage
KG5006 (this page) yes <= 440 V AC
KG5001 yes —
KG5002 yes —
KG5009 yes <= 440 V AC

Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.

Where it sits in the control system

The KG5006 is the device-level element in an IFM circuit breaker installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the <= 440 V AC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides non-flush mountable support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for IFM KG5006

IFM KG5006 Capacitive Sensor. See the manufacturer product information for this catalog number.

  • Breaking capacity Icu/Ics: yes — Confirm the revision of the installed unit before a like-for-like replacement.
  • Enclosure rating: IP20 (IEC 60529) — Use it as the reference when cross-checking a current-production equivalent.
  • Overload capacity: yes — Verify it in the project documentation before confirming the order.
  • Dimensions (H x W x D): M18 x 1 / L = 85 — Check this value against the nameplate of the installed unit before ordering.

For a discontinued unit, match function and electrical ratings rather than the label alone.

Common questions about KG5006

Q.Which value is published under enclosure rating for catalog number KG5006?

For KG5006, enclosure rating is given as IP20 (IEC 60529). Compare it with the nameplate of the installed unit before ordering.

Q.Before ordering KG5006, which operating temperature entry should be checked?

The operating temperature entry quoted above is -25...+60 °C. Confirm this figure against the unit currently in the panel.

Q.Where can I find the certifications data for KG5006?

It is listed in the specification table for IFM KG5006 as CE, cULus. Use the value as the reference when sourcing a current-production equivalent.

Q.How do I confirm compatibility of KG5006 before ordering?

Match the catalog number KG5006 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Q.Can the KG5006 replace the unit currently installed in my panel?

Compare catalog number KG5006 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!