Technical parameters compiled from the manufacturer data sheet and reference documentation.
| Technical Specifications |
| Type Designation |
| Model |
SV2-005L2 |
| Overvoltage category |
III |
| Structure Type |
Attached to base mount |
| Conversion precision |
±20 mV (typ.) |
| Conversion speed |
1.2 ms (typ.) |
| Power Supply |
| Input power supply Main circuit |
3-phase (or single phase) 200 to 240 VAC +10 to -15%, 50/60 Hz ; 270 to 324 VDC |
| CE marking Low-voltage directive |
EN61800-5-1, EN50178 |
| Insulation withstand voltage |
1500 VAC or more (between primary side and ground) ; 3000 VAC or more (between primary side and secondary side) ; 350 VAC: Between secondary circuit and ground |
| Power supply/current capacity and power loss Main circuit power supply |
Three-phase 200 V/Single phase 200 V |
| Power supply capacity for 1 amplifier |
Three-phase 200 V: 0.2 kVA, Single phase 200 V: 0.2 kVA |
| Main circuit power loss |
5.1 W |
| Regenerative resistor power loss |
— |
| Total power loss |
22.1 W |
| At main circuit voltage change |
0% with ±10% of rated voltage (at rated rotation speed) |
| Speed frequency response frequency |
2.6 kHz |
| Rated input voltage |
24 VDC |
| Min. ON voltage |
19 VDC |
| Min. OFF current/voltage |
High-speed input: 0.6 mA, general input: 0.3 mA |
| Residual voltage when ON |
1.5 VDC or less |
| Transmission frequency |
125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms) |
| Inputs & Outputs |
| Output |
EDM: Built-in safety circuit status monitoring (fixed output) ; Max. allowable voltage: 30 VDC ; Max. allowable current: 50 mA DC ; Max. voltage drop at ON: 1.5 V ; Max. delay time: 8 ms ; (Time from changing STO1, STO2 until EDM change) |
| Rated input current Main circuit |
Three-phase 200 V: 0.4 Arms, Single phase 200 V: 0.8 Arms |
| I/O specifications Number of inputs |
7 (3 high-speed input, 4 general input) |
| Input time constant |
250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
| Input impedance |
Approx. 4.7 kΩ |
| Assignable input signals |
Full signal assignment, logic-settable forced stop (FSTOP), ; external latch signals 1 to 3 (EXT1, EXT2, EXT3), ; origin return deceleration switch (DEC), forward limit switch (LSP), ; reverse limit switch (LSN), forward torque limit selection (PTL), ; reverse torque limit selection (NTL) |
| Command input |
MECHATROLINK-III command ; (sequence, motion, monitor, adjustment, etc.) |
| Communication & Interfaces |
| Communication specifications Communication protocol |
MECHATROLINK-III |
| Communication cycle |
Support for values starting at transmission frequency × 1 |
| USB communication Connected device |
PC |
| Communication standard |
USB 2.0-compliant |
| Mechanical |
| Operating environment Enclosure rating |
IP20 |
| Protection function |
Overcurrent, overvoltage, undervoltage, overload, regenerative abnormalities, etc. |
| Weight |
Approx. 0.8 kg |
| Environmental |
| Pollution degree |
Pollution degree: 2 (in an IP54 or higher control panel) ; However, usage under the following requirements required: ; • No corrosive gas or flammable gas present ; • No exposure to water, oil, or chemicals ; • No dust present |
| Operating ambient temperature |
-5 to +60°C 23 to 140°F (no freezing; reduced ratings at +55°C 131°F or more) |
| Storage ambient temperature |
-20 to +85°C -4 to +185°F (no freezing) |
| Altitude |
2000 m 6561.7' or less above sea level (usable at reduced ratings at 1000 m 3280.8' or more) |
| Vibration resistance |
4.9 m/s 16.1'/s (JIS C60068-2-6 compliant) |
| At ambient temperature change |
±0.1% or less with ambient temperatures of 0 to +50°C 32 to 122°F (at rated rotation speed) |
| Compliance, Approvals & Standards |
| Impact resistance |
19.6 m/s 64.3'/s ( JIS C60068-2-27 compliant) |
| Min. insulation resistance |
500 VDC, 1 MΩ or more with insulation resistance tester |
| Applied standard UL/CSA standards |
UL61800-5-1, CSA22.2 No.274 |
| Performance specifications Speed control range |
1:5000 (load torque ≤ rated torque conditions) |
| Other |
| General specifications Capacity |
50 W |
| Control circuit |
Single-phase 200 to 240 VAC +10 to -15%, 50/60 Hz ; 270 to 324 VDC |
| Control mode |
Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method |
| Feedback |
22-bit serial encoder (absolute) communication, ; fully closed control serial communication, analog feedback |
| Other |
No static electricity noise, strong electric fields, magnetic fields, or radiation present |
| EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
| EMS |
EN61800-3, EN61000-6-2 |
| Safety function |
STO function (STO/EN61800-5-2) |
| Response time |
8 ms (max.) |
| Max. |
2.1 Arms |
| Rush current Main circuit |
34 A |
| Speed fluctuation rate At load fluctuation |
±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed) |
| Torque control accuracy (reproducibility) |
±1% |
| Dynamic brake |
Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP) |
| Display Function Panel function |
7-segment LED ; Rotary switch ×2 (16 ch) ; Slide switch ×1 (4 ch) |
| Status display LED |
CHARGE: For notification of main circuit power supply input (orange) ; POWER: For notification of control circuit power supply input (green) ; CONNECT: For notification of connection (green) ; LINK1, LINK2: For notification of MECHATROLINK communication (green) |
| Auxiliary function |
Gain control, alarm history, Z-phase search, etc. |
| Common point mode |
7 points/1 common point (1 terminal) (bidirectional) |
| Rated load |
30 VDC / 50 mA |
| Leakage current when OFF |
0.1 mA |
| Resolution |
±10 bits |
| Line driver |
SN75ALS174 (T.I.) or equivalent |
| Station address |
03H to EFH (Max. number of connectable slaves: 62) |
| Transmission speed |
100 Mbps |
| Number of transmitted bytes |
32 bytes/station, 48 bytes/station (selectable with slide switch) |
| Transmission media/cable |
Category 5e-compliant, STP cross cable |
| Operating specifications |
Position control / speed control / torque control |
Model variants, options and firmware revisions can affect fitment. Before ordering the Keyence SV2-005L2 ac servo drive, share your existing part number or project requirements and our team will cross-reference comparable in-stock Keyence units and verify compatibility. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for identification only.
Independent supplier: Keyence part SV2-005L2 is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.