LR-ZH490CB is a Keyence industrial component with Supply voltage 10...30 V DC (IEC 60947-5-2); Enclosure rating IP67 (IEC 60529); Operating temperature -25...+70 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Supply voltage10...30 V DC (IEC 60947-5-2)
  • Enclosure ratingIP67 (IEC 60529)
  • Operating temperature-25...+70 °C (IEC 60068-2-1)
  • CertificationsCE, cULus

Specifications

Electrical
Supply voltage 10...30 V DC (IEC 60947-5-2)
Power consumption 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)
I/O and communication
Response time < 1 ms
Resolution 1 to 5 (1 to 5 mm 0.04" to 0.20" )
Mechanical
Weight Approx. 75 g
Enclosure rating IP67 (IEC 60529)
Environment and compliance
Operating temperature -25...+70 °C (IEC 60068-2-1)
Storage temperature -25 to +75 °C -13 to 167 °F (No freezing)
Certifications CE, cULus
Humidity 35 to 85 % RH (No condensation)

Values follow the Keyence industrial component specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

Keyence industrial component variants
Catalog number Mounting
LR-ZH490CB (this page) —
LR-ZH500C3P —
LR-ZH500CN —
LR-ZH500CP —

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The LR-ZH490CB is the device-level element in a Keyence industrial component installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides standard panel or DIN-rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for Keyence LR-ZH490CB

Keyence LR-ZH490CB — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number LR-ZH490CB; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.

  • Certifications: CE, cULus — Confirm the revision of the installed unit before a like-for-like replacement.
  • Response time: < 1 ms — Use it as the reference when cross-checking a current-production equivalent.
  • Enclosure rating: IP67 (IEC 60529) — Verify it in the project documentation before confirming the order.
  • Power consumption: 450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V) — Check this value against the nameplate of the installed unit before ordering.

Available from stock with datasheet, certificates and a quotation on request.

Common questions about LR-ZH490CB

Q.Where can I find the humidity data for LR-ZH490CB?

It is listed in the specification table for Keyence LR-ZH490CB as 35 to 85 % RH (No condensation). Confirm this figure against the unit currently in the panel.

Q.For LR-ZH490CB, what does the specification table state about resolution?

The specification table lists resolution = 1 to 5 (1 to 5 mm 0.04" to 0.20" ) for Keyence LR-ZH490CB. Use the value as the reference when sourcing a current-production equivalent.

Q.Which value is published under supply voltage for catalog number LR-ZH490CB?

For LR-ZH490CB, supply voltage is given as 10...30 V DC (IEC 60947-5-2). Check the revision of the installed unit if the catalog number has been superseded.

Q.How do I confirm compatibility of LR-ZH490CB before ordering?

Match the catalog number LR-ZH490CB and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Q.Can the LR-ZH490CB replace the unit currently installed in my panel?

Compare catalog number LR-ZH490CB and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!