Keyence LK-H028 Laser Displacement Sensor Head

SKU: LK-H028
Regular price $3,313.69
In stock (90 units)
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

Keyence · circuit breaker

LK-H028 is a Keyence circuit breaker with Rated operational voltage <= 440 V AC; Breaking capacity Icu/Ics 0.01% of F.S./°C (F.S. = 6 mm 0.24" ); Supply voltage 10...30 V DC (IEC 60947-5-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Rated operational voltage<= 440 V AC
  • Breaking capacity Icu/Ics0.01% of F.S./°C (F.S. = 6 mm 0.24" )
  • Supply voltage10...30 V DC (IEC 60947-5-2)
  • Enclosure ratingIP20 (IEC 60529)

Specifications

Electrical
Rated operational voltage <= 440 V AC
Breaking capacity Icu/Ics 0.01% of F.S./°C (F.S. = 6 mm 0.24" )
Supply voltage 10...30 V DC (IEC 60947-5-2)
Mechanical
Weight Approx. 230 g (including the cable)
Mounting Diffuse reflective
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature -25...+60 °C
Certifications CE, cULus
Humidity 35 to 85 % RH (No condensation)

Values follow the Keyence circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

Keyence circuit breaker variants
Catalog number Breaking capacity Icu/Ics Rated operational voltage
LK-H028 (this page) 0.01% of F.S./°C (F.S. = 6 mm 0.24" ) <= 440 V AC
LK-H020 0.01% of F.S./°C (F.S.= 6 mm 0.24" ) <= 440 V AC
LK-H022 0.01% of F.S./°C (F.S.= 6 mm 0.24" ) <= 440 V AC
LK-H022K 0.01% of F.S./°C (F.S.= 6 mm 0.24" ) <= 440 V AC

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The LK-H028 is the device-level element in a Keyence circuit breaker installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the <= 440 V AC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides Diffuse reflective support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for Keyence LK-H028

Keyence LK-H028 — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number LK-H028; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.

  • Mounting: Diffuse reflective — Record it with the other nameplate data when sourcing a replacement.
  • Supply voltage: 10...30 V DC (IEC 60947-5-2) — Confirm the revision of the installed unit before a like-for-like replacement.
  • Operating temperature: -25...+60 °C — Use it as the reference when cross-checking a current-production equivalent.
  • Enclosure rating: IP20 (IEC 60529) — Verify it in the project documentation before confirming the order.

Cross-check the ratings above with the installed device before confirming the order.

Common questions about LK-H028

Q.For LK-H028, what does the specification table state about mounting?

The specification table lists mounting = Diffuse reflective for Keyence LK-H028. Confirm this figure against the unit currently in the panel.

Q.Which value is published under operating temperature for catalog number LK-H028?

For LK-H028, operating temperature is given as -25...+60 °C. Use the value as the reference when sourcing a current-production equivalent.

Q.Before ordering LK-H028, which weight entry should be checked?

The weight entry quoted above is Approx. 230 g (including the cable). Check the revision of the installed unit if the catalog number has been superseded.

Q.How do I confirm compatibility of LK-H028 before ordering?

Match the catalog number LK-H028 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Q.Can the LK-H028 replace the unit currently installed in my panel?

Compare catalog number LK-H028 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!