Keyence KV-8000A Programmable Logic Controller

SKU: KV-8000A
Regular price $915.36
In stock
Usually ships within 72 hours
Factory pre-tested, ready for instant commissioning!

All industrial automation equipment comes complete with standard matching accessories and detailed step-by-step commissioning manuals. Unbox, install and commission your automation projects smoothly with full confidence.

Free shipping
100% secure payments
Industry leading quality

KV-8000A Programmable Logic Controller | Keyence

The Keyence KV-8000A is a programmable logic controller. The listed technical data shows Maximum 3072 points for expansion I/O points, based on the manufacturer's datasheet. It is supplied by SHLY-PLC, an independent industrial-automation distributor: every unit is visually inspected and functionally checked before dispatch, held in ready stock and shipped worldwide for maintenance, spares and retrofit use. Share your application or existing part number and our team will confirm fitment and comparable in-stock alternatives.

Features

  • Operating ambient temperature: System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F (No freezing) ; System configuration using an expansion unit for KV-8000/7000 Series only: 0 to +55°C 32 to 131°F (No freezing).
  • Weight: KV-8000A: Approx. 340 g ; KV-B1 (battery): Approx. 10 g.
  • Model: KV-8000A.
  • General specifications Power voltage: System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%) ; System configuration using an expansion unit for KV-8000/7000 Series only: 24 VDC (-15%/+20%).
  • Operating ambient temperature: System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F (No freezing) ; System configuration using an expansion unit for KV-8000/7000 Series only: 0 to +55°C 32 to 131°F (No freezing).
  • Operating ambient humidity: System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH (No condensation) ; System configuration using an expansion unit for KV-8000/7000 Series only: 5 to 95% RH (No condensation).

Specifications

Technical parameters compiled from the manufacturer data sheet and reference documentation.

Technical Specifications
Type Designation
Model KV-8000A
Overvoltage category I (II when using KV-PU1)
Power Supply
General specifications Power voltage System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%) ; System configuration using an expansion unit for KV-8000/7000 Series only: 24 VDC (-15%/+20%)
Withstand voltage 1500 VAC, 1 minute (between the power supply terminal and the I/O terminals and between the external terminals and the case)
Vibration resistance Frequency 5 to 9 Hz Half amplitude 3.5 mm 0.14"
Frequency 9 to 150 Hz Acceleration 9.8 m/s 32.2'/s
Continuous vibration Frequency 5 to 9 Hz Half amplitude 1.75 mm 0.07"
Internal current consumption 400 mA or less
Power failure hold function Program memory Flash ROM can be written 10000 times
Inputs & Outputs
I/O control mode Refresh mode
Maximum number of I/O points Maximum 3072 points for expansion ; (KV-EB1S/KV-EB1R: 2 units used, 64-point unit used)
Bit device Input relay R Total 32000 points 1 bit
Bit device Link relay B 32768 points 1 bit
Internal auxiliary relay MR 64000 points 1 bit
Latch relay LR 16000 points 1 bit
Control relay CR 1280 points 1 bit
Mechanical
Weight KV-8000A: Approx. 340 g ; KV-B1 (battery): Approx. 10 g
Environmental
Operating ambient temperature System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F (No freezing) ; System configuration using an expansion unit for KV-8000/7000 Series only: 0 to +55°C 32 to 131°F (No freezing)
Operating ambient humidity System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH (No condensation) ; System configuration using an expansion unit for KV-8000/7000 Series only: 5 to 95% RH (No condensation)
Storage ambient temperature System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F ; System configuration using an expansion unit for KV-8000/7000 Series only: -25 to +75°C -13 to +167°F
Operating altitude 2000 m 6561.7' or less
Shock resistance Acceleration 150 m/s 492.1'/s , Operation time 11 ms, twice in each of the X, Y and Z directions
Pollution degree 2
Compliance, Approvals & Standards
Insulation resistance 50 MΩ or more (between the power terminals and the I/O terminals, and between the external terminals and the case, with 500 VDC megohmmeter)
Performance specifications Arithmetic control mode Stored program mode
Word device Timer T 4000 points 32 bits
Number of comments/ labels stored in main unit Device comment Approx. 224000
Other
Operating environment No dust or corrosive gas
Noise immunity 1500 Vp-p or more ; Pulse width: 1 μs, 50 ns (based on a noise simulator) ; IEC standard-compliant (IEC61000-4-2/3/4/6)
Program language Expanded ladder, KV Script, mnemonic
Number of commands Basic instructions: 80 classes, 181 instructions ; Applied instructions: 55 classes, 73 instructions ; Arithmetic operation instruction: 128 classes, 327 instructions ; Extended instructions: 78 classes, 133 instructions ; Total: 341 classes, 714 instructions
Instruction execution speed Basic instructions: Min. 0.96 ns ; Applied instructions: Min. 5.75 ns ; Double precision floating-point instruction: Min. 58 ns
CPU memory capacity 64 MB
Program capacity Approx. 1500 k steps
Maximum number of units to be installed 16 units (KV-8000/7000 Series expansion unit only) ; 48 units (KV-8000/7000 Series expansion unit, KV-5000/3000 Series ; expansion unit (when extension unit (KV-EB1) is used))
Self-diagnosis function CPU error, RAM error, other
Data memory DM 65535 points 16 bits
File register Current bank FM 524288 points 16 bits
Link register W 32768 points 16 bits
Temporary memory TM 512 points 16 bits
Index register Z 12 points 32 bits
Control memory CM 7600 points 16 bits
Calendar timer Backup condenser lasts approx. 15 days (at 25°C 77°F ) ; (Approx. 5 years with KV-B1 (battery) (at 25°C 77°F ))

Compatibility & Cross-References

Model variants, options and firmware revisions can affect fitment. Before ordering the Keyence KV-8000A programmable logic controller, share your existing part number or project requirements and our team will cross-reference comparable in-stock Keyence units and verify compatibility. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for identification only.

Applications

  • Machine and process automation control for production lines and special-purpose machines.
  • Central logic, sequencing and coordination of sensors, actuators and communication modules.
  • Retrofits, expansions and spare controllers for existing PLC-based systems.
  • Distributed and cabinet-based automation requiring reliable scan and I/O handling.

Warranty

  • Availability: KV-8000A is stocked for prompt shipment; contact us for current quantity and lead time.
  • Inspection & testing: each unit is visually inspected and functionally checked before packing.
  • Delivery: in-stock orders placed before 14:00 ship the same business day; standard worldwide delivery is about 5-8 business days, express shipping is available, and orders over $500 ship free.
  • Warranty & returns: covered by our supplier warranty and standard returns policy; contact our team for full terms.
Independent supplier: Keyence part KV-8000A is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.

Frequently Asked Questions

Q: What condition is the KV-8000A supplied in?

A: Each KV-8000A is inspected and functionally checked before sale. Contact us for the current stock condition and quantity.

Q: How quickly can the KV-8000A ship?

A: In-stock orders placed before 14:00 ship the same business day. Standard worldwide delivery is about 5-8 business days, express shipping is available and orders over $500 ship free.

Q: Can you confirm compatibility or a replacement for the KV-8000A?

A: Yes. Share your existing part number or application and our technical team will verify compatibility and provide cross-references to comparable in-stock models.

KV-8000A · Technical reference data · Independently supplied by SHLY-PLC

Place your order before 14:00 for earliest possible shipment handover. With round-the-clock transit operated by our partnered global logistics providers, parcels reach most international destinations following routine customs processing. Economy shipping takes 5–8 business days, while express delivery arrives in 5–8 business days, both subject to customs clearance progress.Shipping fees will be charged for all orders under USD 500, and the exact shipping cost will be determined and collected by our logistics carriers. Shipments to remote international regions will incur additional courier surcharges to offset extra cross-border transportation costs.

Factory warranty service is not applicable to this industrial control equipment, and extended warranty packages are not provided for this item.

★★★★★

No reviews yet. Be the first to review this product!