Technical parameters compiled from the manufacturer data sheet and reference documentation.
| Technical Specifications |
| Type Designation |
| Model |
KV-8000A |
| Overvoltage category |
I (II when using KV-PU1) |
| Power Supply |
| General specifications Power voltage |
System configuration using an expansion unit for KV-5000/3000 Series: 24 VDC (±10%) ; System configuration using an expansion unit for KV-8000/7000 Series only: 24 VDC (-15%/+20%) |
| Withstand voltage |
1500 VAC, 1 minute (between the power supply terminal and the I/O terminals and between the external terminals and the case) |
| Vibration resistance Frequency 5 to 9 Hz |
Half amplitude 3.5 mm 0.14" |
| Frequency 9 to 150 Hz |
Acceleration 9.8 m/s 32.2'/s |
| Continuous vibration Frequency 5 to 9 Hz |
Half amplitude 1.75 mm 0.07" |
| Internal current consumption |
400 mA or less |
| Power failure hold function Program memory |
Flash ROM can be written 10000 times |
| Inputs & Outputs |
| I/O control mode |
Refresh mode |
| Maximum number of I/O points |
Maximum 3072 points for expansion ; (KV-EB1S/KV-EB1R: 2 units used, 64-point unit used) |
| Bit device Input relay R |
Total 32000 points 1 bit |
| Bit device Link relay B |
32768 points 1 bit |
| Internal auxiliary relay MR |
64000 points 1 bit |
| Latch relay LR |
16000 points 1 bit |
| Control relay CR |
1280 points 1 bit |
| Mechanical |
| Weight |
KV-8000A: Approx. 340 g ; KV-B1 (battery): Approx. 10 g |
| Environmental |
| Operating ambient temperature |
System configuration using an expansion unit for KV-5000/3000 Series: 0 to +50°C 32 to 122°F (No freezing) ; System configuration using an expansion unit for KV-8000/7000 Series only: 0 to +55°C 32 to 131°F (No freezing) |
| Operating ambient humidity |
System configuration using an expansion unit for KV-5000/3000 Series: 10 to 95% RH (No condensation) ; System configuration using an expansion unit for KV-8000/7000 Series only: 5 to 95% RH (No condensation) |
| Storage ambient temperature |
System configuration using an expansion unit for KV-5000/3000 Series: -20 to +70°C -4 to +158°F ; System configuration using an expansion unit for KV-8000/7000 Series only: -25 to +75°C -13 to +167°F |
| Operating altitude |
2000 m 6561.7' or less |
| Shock resistance |
Acceleration 150 m/s 492.1'/s , Operation time 11 ms, twice in each of the X, Y and Z directions |
| Pollution degree |
2 |
| Compliance, Approvals & Standards |
| Insulation resistance |
50 MΩ or more (between the power terminals and the I/O terminals, and between the external terminals and the case, with 500 VDC megohmmeter) |
| Performance specifications Arithmetic control mode |
Stored program mode |
| Word device Timer T |
4000 points 32 bits |
| Number of comments/ labels stored in main unit Device comment |
Approx. 224000 |
| Other |
| Operating environment |
No dust or corrosive gas |
| Noise immunity |
1500 Vp-p or more ; Pulse width: 1 μs, 50 ns (based on a noise simulator) ; IEC standard-compliant (IEC61000-4-2/3/4/6) |
| Program language |
Expanded ladder, KV Script, mnemonic |
| Number of commands |
Basic instructions: 80 classes, 181 instructions ; Applied instructions: 55 classes, 73 instructions ; Arithmetic operation instruction: 128 classes, 327 instructions ; Extended instructions: 78 classes, 133 instructions ; Total: 341 classes, 714 instructions |
| Instruction execution speed |
Basic instructions: Min. 0.96 ns ; Applied instructions: Min. 5.75 ns ; Double precision floating-point instruction: Min. 58 ns |
| CPU memory capacity |
64 MB |
| Program capacity |
Approx. 1500 k steps |
| Maximum number of units to be installed |
16 units (KV-8000/7000 Series expansion unit only) ; 48 units (KV-8000/7000 Series expansion unit, KV-5000/3000 Series ; expansion unit (when extension unit (KV-EB1) is used)) |
| Self-diagnosis function |
CPU error, RAM error, other |
| Data memory DM |
65535 points 16 bits |
| File register Current bank FM |
524288 points 16 bits |
| Link register W |
32768 points 16 bits |
| Temporary memory TM |
512 points 16 bits |
| Index register Z |
12 points 32 bits |
| Control memory CM |
7600 points 16 bits |
| Calendar timer |
Backup condenser lasts approx. 15 days (at 25°C 77°F ) ; (Approx. 5 years with KV-B1 (battery) (at 25°C 77°F )) |
Model variants, options and firmware revisions can affect fitment. Before ordering the Keyence KV-8000A programmable logic controller, share your existing part number or project requirements and our team will cross-reference comparable in-stock Keyence units and verify compatibility. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for identification only.
Independent supplier: Keyence part KV-8000A is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.
A: Each KV-8000A is inspected and functionally checked before sale. Contact us for the current stock condition and quantity.
A: In-stock orders placed before 14:00 ship the same business day. Standard worldwide delivery is about 5-8 business days, express shipping is available and orders over $500 ship free.
A: Yes. Share your existing part number or application and our technical team will verify compatibility and provide cross-references to comparable in-stock models.