| Technical Specifications |
| Type Designation |
| Model |
CV-3002 |
| Type |
Expand, shrink, average, median, edge sharpening, edge extract X, edge extract Y, Sobel, Prewitt,Roberts, Laplacian, binary, subtract, illumination adjustment, contrast conversion, image extraction |
| Coordinateconversion function. |
Coordinate system conversion, rotating matrix |
| Power Supply |
| Rating Power voltage |
24 VDC ±10 % |
| Current consumption |
1.4 A (2 cameras at maximum load) |
| Inputs & Outputs |
| Camera input |
Two color/monochrome cameras (CV-035C/S035C/035M/S035M can beconnected. Mixed connection ispossible.) |
| Support Functions No. of data |
Max. 20000 data (can be saved into a memory card in a batch) |
| Support functions Custom menu function |
Shortcut menu to a desired program screen can be created (20 menus/program). |
| Support Functions Others |
Screen capture function, password function, re-test function, file managementfunction, I/O monitoring, RS-232C monitoring (with log save function) |
| Interface External trigger input |
2-camera simultaneous capture/individual capture can be selected. |
| Control input |
18 inputs ; Input rating 26.4 V or less, 2 mA or more |
| Control output Universal output |
27 outputs NPN (including two FLASH outputs linked to external trigger.) |
| Total comparator output |
1 output, NPN open collector, maximum 50 mA (30 V or less) |
| Monitor output |
SVGA 800x600 (24-bit color 60 Hz) |
| Communication & Interfaces |
| Number of screens that can be registered |
Maximum 1000 screen for each program (depending on the capacity of theinternal memory and memory card)Compression save function. |
| Internal memory capacity ; (Max. number of settings that can be registered, for reference) |
About 15 MB (550 settings) |
| Scan mode switching function (valid only when a monochrome camera is connected) |
Progressive/interlace selectable |
| No. of screens that can be ; displayed simultaneously |
Max. 5 screens can be displayed at the same time (when 5 scr. (HORIZONTAL)/5 scr. (VERTICAL) is selected). |
| RS-232C |
Numerical value output, image data (compressible) and control input/output enabled.Can be used simultaneously with other communication ports.Maximum baud rate of 115200 bps is supported. |
| Ethernet |
Numerical value output, image data (compressible) and control input/output enabled.Can be used simultaneously with other communication ports.100BASE-TX/10BASE-T |
| USB |
Numerical value output, image data (compressible) and control input/output enabled.Can be used simultaneously with other communication ports.USB2.0, HI-SPEED supported |
| Mechanical |
| Trend edge width |
Shapes are rectangle, rotated rectangle, ring and arc. |
| Weight |
Approx. 950 g |
| Environmental |
| Environmental resistance Ambient temperature |
0 to +50 °C 32 to 122 °F |
| Relative humidity |
35 to 85 % RH (No condensation) |
| Compliance, Approvals & Standards |
| White balance adjustment (valid only when a color camera is connected) |
Manual setting using white paper |
| Calculation function Number of settings |
128 calculations/1 program |
| Geometriccalculation |
Distance between 2 points, angle of line segment, circle radius, circle center,average angle, straight line, cross point, distance between a point and a straight line,straight line angle, angle between the two crossed lines, perpendicular line betweena point to a line, perpendicular bisector , midpoint |
| Other |
| No. of pixels |
512 (H) x 480 (V),approx. 240,000 pixels |
| No. of registered settings |
Maximum 1000 programs each in the system and memory card (depending on the memory capacity and program data), externally selectable. |
| Window setting Measurement area |
128 windows/1 program |
| Mask area |
4 mask windows/1 inspection window |
| Color extraction function (valid only when a color camera is connected) |
Color binary processing, color shade processing, gray scale processing (colors can be numerically specified with HSB or RGB values.) |
| Measurement tool Area measurement |
Shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to 12 sides),auto-adjusting rectangle, and auto-adjusting circle |
| Position detection Pattern search |
• Multiple search possible ; • For both pattern area and search area, the shapes are rectangle, rotatedrectangle, circle, oval, ring, arc, and polygon (up to 12 sides) ; • Pattern area can be masked (4 positions/1 area). |
| V-search |
• Simultaneous classification search through up to 256 patterns possible ; • For both pattern area and search area, the shapes are rectangle, rotatedrectangle, circle, oval, ring, arc, and polygon (up to 12 sides) ; • Pattern area can be masked (4 positions/1 area) |
| Edge position |
• Angles can be measured. ; • Shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to 12 sides),auto-adjusting rectangle, and auto-adjusting circle |
| Inspection mode |
Edge position |
| Edge angle |
Shape is rectangle. |
| Blob (characteristicquantities) |
• Number of blobs, center of gravity, main axis angle, area, feret diameter,perimeter, roundness. ; • Shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to 12 sides), auto-adjusting rectangle, and auto-adjusting circle |
| Stain detection |
• Subtract stain detection by using subtract filter ; • Stain grouping function supporting multiple stain detection and positionmeasurement. ; • Shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to 12 sides), auto-adjusting rectangle, and auto-adjusting circle |
| Color (only when acolor camerais connected) |
• RGB and HSV measurement supported ; • Shapes are rectangle, rotated rectangle, circle, oval, ring, arc, and polygon (up to 12 sides) |
| Geometry |
• Calculation result can be reflected. ; • Shapes are point, line, and circle. |
| OCR |
• Character recognition for max. 2 lines of 20 characters per line ; • Shape is rectangle |
| Continuous capture function |
• 1 to 32-time multi-measurement (maximum, minimum and average values) ; • Error values can be excluded from the measurement result. |
| Execution condition setting function |
Can set whether to execute the results (OK/NG) for other measurement andcalculation windows in each measurement window. |
| Image capturing ; setting function Processing area setting function |
The applicable 240,000 pixels (512 (H) x480 (V)) can be captured from 320,000pixels. |
| Capturing start/end line setting function |
Desired capture start/end line can be set within the image capture range. (Two lines are counted as one unit with the interlace method.) |
| Correction ; functions Position adjustment |
Batch, individual (maximum 64 settings), X, Y, ±180° rotation. |
| Camera gain adjustment |
Sensitivity adjustment, offset, and span adjustment (RGB batch/individual and span can be set for each of 16 brightness levels. RGBindividual setting can be supported when color camera is conencted.) |
| Filter function Count |
The same type of filter can be used up to 9 times. 13 steps. (For binarization and subtract only : 1 step/window) |
| Scaling |
X and Y calibration setting for each camera. Conversion from measurement valuesand calculation values is supported. |
| Arithmetic operation |
Sum (+), subtract (-), multiply (x), divide (÷) |
| Arithmeticfunction |
Square, exponential, counting fractions as one, round-off fractions, maximum, minimum, average, average within range,square root, absolute value, remainder, distance, angle, sin, cos, tan, asin, acos, atan, π |
| Comparative operator |
<, ==, Not |
| Logical operator |
AND, OR, NOT, XOR |
| Sort function |
Maximum value index output, minimum value index output |
| System function |
Number of measurement times, measurement time, year, month, day, time, minute, second |
| Time axis operationfunction |
Previous measurement result acquisition operator |
| Command memory |
Equipped with 128 command memory entries that can be rewritten from an external device and from the console during operation |
| Statistical item |
Maximum, minimum, average value, deviation (3σ), total status OK/NG times |
| Screen save (valid when monochrome ; and color cameras are connected) |
The following number of screens can besaved in the systemís memory : ; • Maximum 511 images (when using amonochrome camera) ; • Maximum 169 images (when using acolor camera) (These are the maximum values withonly one camera connected, and[Condition] set to [All Images].) |
| programming aid functions Screen Magnification |
Between 4% and 1600% during setting or operation (6% and 2500% during fullscreen display) (Size can be set for each screen while diplaying multiple screens.) |
| Edge WaveformDisplay |
Edge waveform can be graphically displayed during setting or operation, and edgeintensity and measurement values (some are not supported) can be displayed duringsetting. |
| Profile Display |
Trend edge position and gap can be graphically displayed during setting oroperation. |
| Stability display |
Stain detection (stain level) is displayed during setting or operation. |
| Shift all windows |
Selected windows from an identical camera or an identical registered image can beshifted in the desired XY direction in a group. |
| Display templates setting ; function No. of display |
10 templates/1 program (within which 4 templates are specified values), externallyselectable |
| Hold image |
Up to the past three images (NG images) can be displayed as hold images.measurement results and measurement time can be viewed. (The number of displayable times varies between 0 and 3 depending on camera'sconnection state.) |
| Screen customization function No. of customization screens |
10 screens/1 program |
| Custom item |
Character string : Measurement value (decimal point can be specified), result, customcharacter, graphics, active text |
| Measurementresult interlink |
• Display color can be changed according to the result for figures and customcharacters. ; • Can set a message in the allocation table that relates to the measurementvalue (active text) |
| Operation rewrite function |
Upper/lower tolerance or command memory can be rewritten during opration. |
| Memory card save function |
• Measurement value, judgment result, NG count, measurement image (compressible), stored image (compressible), captured image, statistics analysisdata, RS-232C communication log, program data• Can save data during test run (except for program data). |
| PLC link |
Numerical value output and control input/output using the RS-232C port orEthernet port enabled.Following PLCs are supported via link unit : • KEYKENCE CORP. : KV-700 series, KV-1000 series• Mitsubishi Electric : A series (RS-232C only), Q series• OMRON : SYSMAC C series (RS-232C only), CJ/CJ1 series |
| Display language |
Japanese/English/German selectable |
Model variants, options and firmware revisions can affect fitment. Before ordering the Keyence CV-3002 machine vision system, share your existing part number or project requirements and our team will cross-reference comparable in-stock Keyence units and verify compatibility. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for identification only.
Independent supplier: Keyence part CV-3002 is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.
A: Each CV-3002 is inspected and functionally checked before sale. Contact us for the current stock condition and quantity.
A: In-stock orders placed before 14:00 ship the same business day. Standard worldwide delivery is about 5-8 business days, express shipping is available and orders over $500 ship free.
A: Yes. Share your existing part number or application and our technical team will verify compatibility and provide cross-references to comparable in-stock models.