Keyence · inductive sensor
AH-110 is a Keyence inductive sensor with Supply voltage 10...30 V DC; Enclosure rating IP67 (IEC 60529); Response time <= 1500 Hz switching frequency. It is used in conveyor object detection, machine guarding, position feedback where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage10...30 V DC
-
Enclosure ratingIP67 (IEC 60529)
-
Response time<= 1500 Hz switching frequency
-
Operating temperature-25...+70 °C
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| Output voltage |
0 to 2V |
| Power consumption |
5VA |
| I/O and communication |
| Response time |
<= 1500 Hz switching frequency |
| Resolution |
0.1% of F.S. |
| Mechanical |
| Enclosure rating |
IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C |
| Certifications |
CE, cULus |
| Humidity |
35 to 85 % RH (No condensation) |
Values follow the Keyence inductive sensor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Keyence inductive sensor variants |
| Catalog number |
Supply voltage |
|
AH-110 (this page) |
10...30 V DC |
| AH-416 |
10...30 V DC |
| AH-422 |
10...30 V DC |
| AH-809 |
10...30 V DC |
Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.
Where it sits in the control system
The AH-110 is the device-level element in a Keyence inductive sensor installation. It receives the field signals and control supply listed above — 10...30 V DC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in conveyor object detection, machine guarding, position feedback, where the unit is matched to the original catalog number and the enclosure provides standard panel or DIN-rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Keyence AH-110
Keyence AH-110 Sensor Head. See the manufacturer product information for this catalog number.
- Enclosure rating: IP67 (IEC 60529) — Match it to the existing panel and upstream protection.
- Operating temperature: -25...+70 °C — Record it with the other nameplate data when sourcing a replacement.
- Certifications: CE, cULus — Confirm the revision of the installed unit before a like-for-like replacement.
- Response time: <= 1500 Hz switching frequency — Use it as the reference when cross-checking a current-production equivalent.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about AH-110
Q.Where can I find the supply voltage data for AH-110?
It is listed in the specification table for Keyence AH-110 as 10...30 V DC. Compare it with the nameplate of the installed unit before ordering.
Q.For AH-110, what does the specification table state about enclosure rating?
The specification table lists enclosure rating = IP67 (IEC 60529) for Keyence AH-110. Confirm this figure against the unit currently in the panel.
Q.Which value is published under response time for catalog number AH-110?
For AH-110, response time is given as <= 1500 Hz switching frequency. Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for AH-110?
Send the full catalog number AH-110, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Keyence AH-110.
Q.How do I confirm compatibility of AH-110 before ordering?
Match the catalog number AH-110 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.