IFM · Inductive proximity sensor
II5448 is an IFM circuit breaker with Breaking capacity Icu/Ics yes; Supply voltage 10...30 V DC (IEC 60947-5-2); Enclosure rating IP67 (IEC 60529). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Breaking capacity Icu/Icsyes
-
Supply voltage10...30 V DC (IEC 60947-5-2)
-
Enclosure ratingIP67 (IEC 60529)
-
Operating temperature-25...+70 °C (IEC 60068-2-1)
Specifications
| Electrical |
| Breaking capacity Icu/Ics |
yes |
| Supply voltage |
10...30 V DC (IEC 60947-5-2) |
| Frequency |
250 Hz |
| Overload capacity |
yes |
| Rated torque |
50 Nm |
| I/O and communication |
| Response time |
<= 1500 Hz switching frequency |
| Mechanical |
| Dimensions (H x W x D) |
M30 x 1.5 / L = 75 mm |
| Weight |
165 g |
| Enclosure rating |
IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the IFM Inductive proximity sensor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| IFM Inductive proximity sensor variants |
| Catalog number |
Breaking capacity Icu/Ics |
|
II5448 (this page) |
yes |
| II5441 |
yes |
| II5430 |
yes |
| II5452 |
no |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The II5448 is the device-level element in an IFM circuit breaker installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides standard panel or DIN-rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for IFM II5448
IFM II5448 — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number II5448; record the nameplate data of the unit being replaced before selecting an equivalent.
- Breaking capacity Icu/Ics: yes — Record it with the other nameplate data when sourcing a replacement.
- Frequency: 250 Hz — Confirm the revision of the installed unit before a like-for-like replacement.
- Rated torque: 50 Nm — Use it as the reference when cross-checking a current-production equivalent.
- Overload capacity: yes — Verify it in the project documentation before confirming the order.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about II5448
Q.Where can I find the frequency data for II5448?
It is listed in the specification table for IFM II5448 as 250 Hz. Confirm this figure against the unit currently in the panel.
Q.For II5448, what does the specification table state about weight?
The specification table lists weight = 165 g for IFM II5448. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under response time for catalog number II5448?
For II5448, response time is given as <= 1500 Hz switching frequency. Check the revision of the installed unit if the catalog number has been superseded.
Q.What should I include in an enquiry for II5448?
Send the full catalog number II5448, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for IFM II5448.
Q.How do I confirm compatibility of II5448 before ordering?
Match the catalog number II5448 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.