IFM · I/O Module
AL1930 is an IFM circuit breaker with Rated operational voltage <= 440 V AC; Breaking capacity Icu/Ics yes; Supply voltage 24 V DC (IEC 61131-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated operational voltage<= 440 V AC
-
Breaking capacity Icu/Icsyes
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated operational voltage |
<= 440 V AC |
| Breaking capacity Icu/Ics |
yes |
| Supply voltage |
24 V DC (IEC 61131-2) |
| I/O and communication |
| Bus interface |
EtherCAT |
| Communication ports |
Ethernet; IO-Link |
| Mechanical |
| Weight |
330.5 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C |
| Storage temperature |
-25...85 °C |
| Certifications |
CE, cULus |
Values follow the IFM I/O Module specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| IFM I/O Module variants |
| Catalog number |
Breaking capacity Icu/Ics |
Rated operational voltage |
|
AL1930 (this page) |
yes |
<= 440 V AC |
| AL1900 |
yes |
<= 440 V AC |
| AL1920 |
yes |
<= 440 V AC |
| AL1940 |
— |
— |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The AL1930 is the device-level element in an IFM circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the <= 440 V AC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for IFM AL1930
IFM AL1930 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number AL1930; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Mounting: 35 mm DIN rail (IEC 60715) — Verify it in the project documentation before confirming the order.
- Weight: 330.5 g — Check this value against the nameplate of the installed unit before ordering.
- Enclosure rating: IP20 (IEC 60529) — Match it to the existing panel and upstream protection.
- Communication ports: Ethernet; IO-Link — Record it with the other nameplate data when sourcing a replacement.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about AL1930
Q.Before ordering AL1930, which storage temperature entry should be checked?
The storage temperature entry quoted above is -25...85 °C. Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the operating temperature data for AL1930?
It is listed in the specification table for IFM AL1930 as -25...+60 °C. Compare it with the nameplate of the installed unit before ordering.
Q.For AL1930, what does the specification table state about communication ports?
The specification table lists communication ports = Ethernet; IO-Link for IFM AL1930. Confirm this figure against the unit currently in the panel.
Q.Can the AL1930 replace the unit currently installed in my panel?
Compare catalog number AL1930 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of AL1930 before ordering?
Match the catalog number AL1930 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.