Delta · DVP Slim Series CPUs
DVP-12SE11R is a Delta 12 I/O Network Type Advanced Slim PLC. It is used in packaging machines, conveyor transfer cells, small process skids where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Total I/O |
12 |
| Supply voltage |
24 V DC (IEC 61131-2) |
| Mechanical |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Product type and series follow the official Delta download-centre catalogue entry for this order number which classifies DVP-12SE11R as "12 I/O network type advanced slim PLC". Source: https://downloadcenter.deltaww.com/en-US/DownloadCenter?q=DVP12SE11R. Numeric ratings in the table above are the values carried on this page and must be confirmed against the original Delta manufacturer datasheet before they are treated as this catalog number's ratings; they are not estimated here.
Model comparison in the same family
| Delta DVP Slim Series CPUs variants |
| Catalog number |
Supply voltage |
|
DVP-12SE11R (this page) |
24 V DC (IEC 61131-2) |
| DVP-12SA11R |
24 V DC (IEC 61131-2) |
| DVP-12SA2 |
24 V DC (IEC 61131-2) |
| DVP-12SA211R |
24 V DC (IEC 61131-2) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The DVP-12SE11R is the controller element in a Delta control installation. It receives the field signals and control supply listed above and switches or conditions the load within the rated values shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in packaging machines, conveyor transfer cells, small process skids, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Delta DVP-12SE11R
Delta DVP-12SE11R — PLC / CPU module used as the device-level control core in an automation panel, handling logic, timing and communication tasks. The figures below are taken from the specification table on this page for catalog number DVP-12SE11R; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Operating temperature: 0...+55 °C (IEC 60068-2-1) — Record it with the other nameplate data when sourcing a replacement.
- Certifications: CE, UL, cULus — Confirm the revision of the installed unit before a like-for-like replacement.
- Enclosure rating: IP20 (IEC 60529) — Use it as the reference when cross-checking a current-production equivalent.
- Supply voltage: 24 V DC (IEC 61131-2) — Verify it in the project documentation before confirming the order.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about DVP-12SE11R
Q.Which official Delta document defines DVP-12SE11R?
The official Delta download-centre catalogue entry for this order number classifies DVP-12SE11R as "12 I/O network type advanced slim PLC". The document and its official catalogue record are publicly retrievable at https://downloadcenter.deltaww.com/en-US/DownloadCenter?q=DVP12SE11R. Use that document as the authority for ratings and installation conditions before ordering.
Q.What does the official Delta catalogue state about the point configuration of DVP-12SE11R?
The official Delta download-centre record for DVP-12SE11R describes this order number as "12 I/O network type advanced slim PLC", so the specification table lists Total I/O = 12. Source: https://downloadcenter.deltaww.com/en-US/DownloadCenter?q=DVP12SE11R
Q.Before ordering DVP-12SE11R, which certifications entry should be checked?
The certifications entry quoted above is CE, UL, cULus. Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the supply voltage data for DVP-12SE11R?
It is listed in the specification table for Delta DVP-12SE11R as 24 V DC (IEC 61131-2). Compare it with the nameplate of the installed unit before ordering.
Q.For DVP-12SE11R, what does the specification table state about enclosure rating?
The specification table lists enclosure rating = IP20 (IEC 60529) for Delta DVP-12SE11R. Confirm this figure against the unit currently in the panel.
Q.Can the DVP-12SE11R replace the unit currently installed in my panel?
Compare catalog number DVP-12SE11R and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for DVP-12SE11R?
Send the full catalog number DVP-12SE11R, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Delta DVP-12SE11R.