Delta · Temperature Controller
DTB4824CR is a Delta Temperature Controller. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
Specifications
| Electrical |
| Supply voltage |
24 V DC (IEC 61131-2) |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Product type and series follow the official Delta download-centre catalogue search for this model which lists DTB4824CR under the Delta product line; the product type published for this catalog number is "Temperature Controller". Source: https://downloadcenter.deltaww.com/en-US/DownloadCenter?q=DTB4824CR. Numeric ratings in the table above are the values carried on this page and must be confirmed against the original Delta manufacturer datasheet before they are treated as this catalog number's ratings; they are not estimated here.
Model comparison in the same family
| Delta Temperature Controller variants |
| Catalog number |
Mounting |
|
DTB4824CR (this page) |
DIN rail / panel |
| DTB4824RR |
DIN rail / panel |
| DTB4824VR |
DIN rail / panel |
| DTB4848VRT |
DIN rail / panel |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The DTB4824CR is the controller element in a Delta control installation. It receives the field signals and control supply listed above and switches or conditions the load within the rated values shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Delta DTB4824CR
Delta DTB4824CR — PLC / CPU module used as the device-level control core in an automation panel, handling logic, timing and communication tasks. The figures below are taken from the specification table on this page for catalog number DTB4824CR; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Operating temperature: 0...+55 °C (IEC 60068-2-1) — Verify it in the project documentation before confirming the order.
- Certifications: CE, UL, cULus — Check this value against the nameplate of the installed unit before ordering.
- Supply voltage: 24 V DC (IEC 61131-2) — Match it to the existing panel and upstream protection.
- Mounting: DIN rail / panel — Record it with the other nameplate data when sourcing a replacement.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about DTB4824CR
Q.Which official Delta document defines DTB4824CR?
The official Delta download-centre catalogue search for this model lists DTB4824CR under the Delta product line, and the product type published for this catalog number is "Temperature Controller". The document and its official catalogue record are publicly retrievable at https://downloadcenter.deltaww.com/en-US/DownloadCenter?q=DTB4824CR. Use that document as the authority for ratings and installation conditions before ordering.
Q.For DTB4824CR, what does the specification table state about supply voltage?
The specification table lists supply voltage = 24 V DC (IEC 61131-2) for Delta DTB4824CR. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under mounting for catalog number DTB4824CR?
For DTB4824CR, mounting is given as DIN rail / panel. Check the revision of the installed unit if the catalog number has been superseded.
Q.Before ordering DTB4824CR, which certifications entry should be checked?
The certifications entry quoted above is CE, UL, cULus. Compare it with the nameplate of the installed unit before ordering.
Q.What should I include in an enquiry for DTB4824CR?
Send the full catalog number DTB4824CR, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Delta DTB4824CR.
Q.How do I confirm compatibility of DTB4824CR before ordering?
Match the catalog number DTB4824CR and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.