Beckhoff · EtherCAT Terminal
EL4022 is a Beckhoff industrial component with Supply voltage 24 V DC (IEC 61131-2); Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Tripping characteristic |
8…9 mm |
| Supply voltage |
24 V DC (IEC 61131-2) |
| I/O and communication |
| Bus interface |
typ. 140 mA |
| Communication ports |
EtherCAT, Ethernet |
| Resolution |
12 bit |
| Mechanical |
| Dimensions (H x W x D) |
12 mm x 100 mm x 68 mm |
| Weight |
approx. 60 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Storage temperature |
-40…+85°C |
| Certifications |
CE, UL, cULus |
| Humidity |
95%, no condensation |
Values follow the Beckhoff EtherCAT Terminal specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Beckhoff EtherCAT Terminal variants |
| Catalog number |
Mounting |
|
EL4022 (this page) |
35 mm DIN rail (IEC 60715) |
| EL4024 |
35 mm DIN rail (IEC 60715) |
| EL4002 |
35 mm DIN rail (IEC 60715) |
| EL4004 |
35 mm DIN rail (IEC 60715) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The EL4022 is the device-level element in a Beckhoff industrial component installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Beckhoff EL4022
Beckhoff EL4022 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number EL4022; record the nameplate data of the unit being replaced before selecting an equivalent.
- Mounting: 35 mm DIN rail (IEC 60715) — Confirm the revision of the installed unit before a like-for-like replacement.
- Bus interface: typ. 140 mA — Use it as the reference when cross-checking a current-production equivalent.
- Storage temperature: -40…+85°C — Verify it in the project documentation before confirming the order.
- Dimensions (H x W x D): 12 mm x 100 mm x 68 mm — Check this value against the nameplate of the installed unit before ordering.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about EL4022
Q.Which value is published under operating temperature for catalog number EL4022?
For EL4022, operating temperature is given as 0...+55 °C (IEC 60068-2-1). Confirm this figure against the unit currently in the panel.
Q.Before ordering EL4022, which weight entry should be checked?
The weight entry quoted above is approx. 60 g. Use the value as the reference when sourcing a current-production equivalent.
Q.Where can I find the storage temperature data for EL4022?
It is listed in the specification table for Beckhoff EL4022 as -40…+85°C. Check the revision of the installed unit if the catalog number has been superseded.
Q.How do I confirm compatibility of EL4022 before ordering?
Match the catalog number EL4022 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.What should I include in an enquiry for EL4022?
Send the full catalog number EL4022, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Beckhoff EL4022.