Beckhoff · EtherCAT Terminal
EL1502 is a Beckhoff circuit breaker with Tripping characteristic 8…9 mm; Rated operational voltage 24 V DC (-15%/+20%); Supply voltage 24 V DC (IEC 61131-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Tripping characteristic8…9 mm
-
Rated operational voltage24 V DC (-15%/+20%)
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated operational voltage |
24 V DC (-15%/+20%) |
| Tripping characteristic |
8…9 mm |
| Supply voltage |
24 V DC (IEC 61131-2) |
| Output current |
24 V/0.5 A (short-circuit proof) per channel |
| Frequency |
max. 100 kHz |
| I/O and communication |
| Bus interface |
typ. 130 mA |
| Communication ports |
EtherCAT, Ethernet |
| Mechanical |
| Dimensions (H x W x D) |
12 mm x 100 mm x 68 mm |
| Weight |
approx. 50 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Storage temperature |
-40…+85°C |
| Certifications |
CE, UL, cULus |
| Humidity |
95%, no condensation |
Values follow the Beckhoff EtherCAT Terminal specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Beckhoff EtherCAT Terminal variants |
| Catalog number |
Tripping characteristic |
Rated operational voltage |
|
EL1502 (this page) |
8…9 mm |
24 V DC (-15%/+20%) |
| EL1512 |
8…9 mm |
24 V DC (-15%/+20%) |
| EL1002 |
— |
— |
| EL1004 |
— |
— |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The EL1502 is the device-level element in a Beckhoff circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the 24 V DC (-15%/+20%) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Beckhoff EL1502
Beckhoff EL1502 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number EL1502; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Humidity: 95%, no condensation — Use it as the reference when cross-checking a current-production equivalent.
- Storage temperature: -40…+85°C — Verify it in the project documentation before confirming the order.
- Mounting: 35 mm DIN rail (IEC 60715) — Check this value against the nameplate of the installed unit before ordering.
- Dimensions (H x W x D): 12 mm x 100 mm x 68 mm — Match it to the existing panel and upstream protection.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about EL1502
Q.Where can I find the enclosure rating data for EL1502?
It is listed in the specification table for Beckhoff EL1502 as IP20 (IEC 60529). Use the value as the reference when sourcing a current-production equivalent.
Q.For EL1502, what does the specification table state about rated operational voltage?
The specification table lists rated operational voltage = 24 V DC (-15%/+20%) for Beckhoff EL1502. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under humidity for catalog number EL1502?
For EL1502, humidity is given as 95%, no condensation. Compare it with the nameplate of the installed unit before ordering.
Q.What should I include in an enquiry for EL1502?
Send the full catalog number EL1502, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Beckhoff EL1502.
Q.How do I confirm compatibility of EL1502 before ordering?
Match the catalog number EL1502 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.