Balluff · BES Q40KFU-PAC40E-S04G
BES021M is a Balluff industrial component with Enclosure rating IP67 (IEC 60529); Operating temperature -10...+70 °C (IEC 60068-2-1); Mounting 40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Enclosure ratingIP67 (IEC 60529)
-
Operating temperature-10...+70 °C
-
Mounting40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin
-
CertificationsCE, UKCA, cULus, WEEE
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| I/O and communication |
| Sensing distance Sn |
40 mm |
| Response time |
100 Hz |
| Output type (PNP/NPN) |
PNP normally open/normally |
| Mechanical |
| Dimensions (H x W x D) |
40 x 40 x 62 mm |
| Mounting |
40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin |
| Connection |
Connector, M12x1-Male, 4-pin |
| Housing material |
PBT |
| Material sensing surface |
PBT |
| Enclosure rating |
IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-10...+70 °C |
| Certifications |
CE, UKCA, cULus, WEEE |
| Magnetic field immune |
magnetic field immune (AC/DC) |
| Additional features |
Factor 1 |
Values follow the Balluff BES Q40KFU-PAC40E-S04G specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Balluff BES Q40KFU-PAC40E-S04G variants |
| Catalog number |
Mounting |
|
BES021M (this page) |
40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin |
| BES0216 |
40x40 square housing, for flush mounting (factor 1), connector M12x1 male 4-pin |
| BES021H |
40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin |
| BES0221 |
40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin |
Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.
Where it sits in the control system
The BES021M is the device-level element in a Balluff industrial component installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides 40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial Q40KFU-PAC40E-S04G
Balluff BES021M Inductive Proximity Sensor. See the manufacturer product information for this catalog number.
- Dimensions (H x W x D): 40 x 40 x 62 mm — Check this value against the nameplate of the installed unit before ordering.
- Output type (PNP/NPN): PNP, NO/NC — Match it to the existing panel and upstream protection.
- Certifications: CE, UKCA, cULus, WEEE — Record it with the other nameplate data when sourcing a replacement.
- Operating temperature: -10...+70 °C (IEC 60068-2-1) — Confirm the revision of the installed unit before a like-for-like replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about Q40KFU-PAC40E-S04G
Q.Where can I find the mounting data for Q40KFU-PAC40E-S04G?
It is listed in the specification table for Industrial Q40KFU-PAC40E-S04G as 40x40 PBT square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin. Use the value as the reference when sourcing a current-production equivalent.
Q.For Q40KFU-PAC40E-S04G, what does the specification table state about output type (PNP/NPN)?
The specification table lists output type (PNP/NPN) = PNP, NO/NC for Industrial Q40KFU-PAC40E-S04G. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under enclosure rating for catalog number Q40KFU-PAC40E-S04G?
For Q40KFU-PAC40E-S04G, enclosure rating is given as IP67 (IEC 60529). Compare it with the nameplate of the installed unit before ordering.
Q.What should I include in an enquiry for Q40KFU-PAC40E-S04G?
Send the full catalog number Q40KFU-PAC40E-S04G, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Industrial Q40KFU-PAC40E-S04G.
Q.How do I confirm compatibility of Q40KFU-PAC40E-S04G before ordering?
Match the catalog number Q40KFU-PAC40E-S04G and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.