Balluff · BES Q40KFU-PAC20A-S04G
BES0216 is a Balluff industrial component with Enclosure rating IP67 (IEC 60529); Operating temperature -25...+70 °C (IEC 60068-2-1); Mounting 40x40 PBT square housing, for flush mounting (factor 1), connector M12x1 male 4-pin. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Enclosure ratingIP67 (IEC 60529)
-
Operating temperature-25...+70 °C
-
Mounting40x40 PBT square housing, for flush mounting (factor 1), connector M12x1 male 4-pin
-
CertificationsCE, UKCA, cULus, WEEE
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| I/O and communication |
| Sensing distance Sn |
20 mm |
| Response time |
400 Hz |
| Output type (PNP/NPN) |
PNP normally open/normally closed (NO/NC) Remarks |
| Mechanical |
| Dimensions (H x W x D) |
40 x 40 x 62 mm |
| Mounting |
40x40 PBT square housing, for flush mounting (factor 1), connector M12x1 male 4-pin |
| Connection |
Connector, M12x1-Male, 4-pin |
| Housing material |
PBT |
| Material sensing surface |
PBT |
| Enclosure rating |
IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C |
| Certifications |
CE, UKCA, cULus, WEEE |
| Magnetic field immune |
magnetic field immune (AC/DC) |
| Additional features |
Factor 1, Weld immune |
Values follow the Balluff BES Q40KFU-PAC20A-S04G specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Balluff BES Q40KFU-PAC20A-S04G variants |
| Catalog number |
Mounting |
|
BES0216 (this page) |
40x40 PBT square housing, for flush mounting (factor 1), connector M12x1 male 4-pin |
| BES021H |
40x40 square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin |
| BES021M |
40x40 square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin |
| BES0221 |
40x40 square housing, non-flush, magnetic-field-resistant (factor 1), connector M12x1 male 4-pin |
Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.
Where it sits in the control system
The BES0216 is the device-level element in a Balluff industrial component installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides 40x40 PBT square housing, for flush mounting (factor 1), connector M12x1 male 4-pin support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial Q40KFU-PAC20A-S04G
Balluff BES0216 Inductive Proximity Sensor. See the manufacturer product information for this catalog number.
- Mounting: 40x40 PBT square housing, for flush mounting (factor 1), connector M12x1 male 4-pin — Use it as the reference when cross-checking a current-production equivalent.
- Output type (PNP/NPN): PNP, NO/NC — Verify it in the project documentation before confirming the order.
- Certifications: CE, UKCA, cULus, WEEE — Check this value against the nameplate of the installed unit before ordering.
- Dimensions (H x W x D): 40 x 40 x 62 mm — Match it to the existing panel and upstream protection.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about Q40KFU-PAC20A-S04G
Q.Before ordering Q40KFU-PAC20A-S04G, which certifications entry should be checked?
The certifications entry quoted above is CE, UKCA, cULus, WEEE. Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the mounting data for Q40KFU-PAC20A-S04G?
It is listed in the specification table for Industrial Q40KFU-PAC20A-S04G as 40x40 PBT square housing, for flush mounting (factor 1), connector M12x1 male 4-pin. Compare it with the nameplate of the installed unit before ordering.
Q.For Q40KFU-PAC20A-S04G, what does the specification table state about dimensions (H x W x D)?
The specification table lists dimensions (H x W x D) = 40 x 40 x 62 mm for Industrial Q40KFU-PAC20A-S04G. Confirm this figure against the unit currently in the panel.
Q.Can the Q40KFU-PAC20A-S04G replace the unit currently installed in my panel?
Compare catalog number Q40KFU-PAC20A-S04G and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for Q40KFU-PAC20A-S04G?
Send the full catalog number Q40KFU-PAC20A-S04G, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Industrial Q40KFU-PAC20A-S04G.