Balluff · BCS capacitive sensor head
BCS00W7 is a Balluff industrial component with Supply voltage 10...30 V DC; Enclosure rating IP65 (IEC 60529); Operating temperature -25...+70 °C. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage10...30 V DC
-
Enclosure ratingIP65 (IEC 60529)
-
Operating temperature-25...+70 °C
-
MountingG20 cylindrical compact housing, Ø 20 x 81 mm, 1.4301 stainless steel housing, for flush mounting, 3.00 m PVC cable
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| Response time |
100 Hz |
| Sensing distance Sn |
1.5...10 mm (adjustable) |
| Mechanical |
| Dimensions (H x W x D) |
Ø 20 x 81 mm |
| Mounting |
G20 cylindrical compact housing, Ø 20 x 81 mm, 1.4301 stainless steel housing, for flush mounting, 3.00 m PVC cable |
| Connection |
Cable, 3.00 m, PVC |
| Housing material |
1.4301 stainless steel |
| Enclosure rating |
IP65 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C |
| Material sensing surface |
LCP |
| Certifications |
CE, UKCA, WEEE |
Values follow the Balluff BCS capacitive sensor head specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Balluff BCS capacitive sensor head variants |
| Catalog number |
Mounting |
|
BCS00W7 (this page) |
G20 cylindrical compact housing, Ø 20 x 81 mm, 1.4301 stainless steel housing, for flush mounting, 3.00 m PVC cable |
| BCS00A1 |
M18 threaded housing, non-flush, special connector |
| BCS006K |
S01 level sensor housing, non-flush, clamping terminal |
| BCS006H |
S01 level sensor housing, non-flush, clamping terminal |
Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.
Where it sits in the control system
The BCS00W7 is the device-level element in a Balluff industrial component installation. It receives the field signals and control supply listed above — 10...30 V DC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides G20 cylindrical compact housing, Ø 20 x 81 mm, 1.4301 stainless steel housing, for flush mounting, 3.00 m PVC cable support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial G20L4Q-PAC10C-EV03-D03
Balluff BCS00W7 Capacitive Sensor. See the manufacturer product information for this catalog number.
- Certifications: CE, UKCA, WEEE — Check this value against the nameplate of the installed unit before ordering.
- Enclosure rating: IP65 (IEC 60529) — Match it to the existing panel and upstream protection.
- Operating temperature: -25...+70 °C — Record it with the other nameplate data when sourcing a replacement.
- Mounting: G20 cylindrical compact housing, Ø 20 x 81 mm, 1.4301 stainless steel housing, for flush mounting, 3.00 m PVC cable — Confirm the revision of the installed unit before a like-for-like replacement.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about G20L4Q-PAC10C-EV03-D03
Q.Which value is published under dimensions (H x W x D) for catalog number G20L4Q-PAC10C-EV03-D03?
For G20L4Q-PAC10C-EV03-D03, dimensions (H x W x D) is given as Ø 20 x 81 mm. Use the value as the reference when sourcing a current-production equivalent.
Q.Before ordering G20L4Q-PAC10C-EV03-D03, which mounting entry should be checked?
The mounting entry quoted above is G20 cylindrical compact housing, Ø 20 x 81 mm, 1.4301 stainless steel housing, for flush mounting, 3.00 m PVC cable. Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the operating temperature data for G20L4Q-PAC10C-EV03-D03?
It is listed in the specification table for Industrial G20L4Q-PAC10C-EV03-D03 as -25...+70 °C. Compare it with the nameplate of the installed unit before ordering.
Q.Can the G20L4Q-PAC10C-EV03-D03 replace the unit currently installed in my panel?
Compare catalog number G20L4Q-PAC10C-EV03-D03 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for G20L4Q-PAC10C-EV03-D03?
Send the full catalog number G20L4Q-PAC10C-EV03-D03, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Industrial G20L4Q-PAC10C-EV03-D03.