B&R · B&R X20 I/O module

X20SLX806 is a B&R circuit breaker with Breaking capacity Icu/Ics Type 1; Supply voltage 24 V DC (IEC 61131-2); Enclosure rating IP20 (IEC 60529). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Breaking capacity Icu/IcsType 1
  • Supply voltage24 V DC (IEC 61131-2)
  • Enclosure ratingIP20 (IEC 60529)
  • Mounting35 mm DIN rail (IEC 60715)

Specifications

Electrical
Rated insulation voltage Ui 500 V eff
Breaking capacity Icu/Ics Type 1
Supply voltage 24 V DC (IEC 61131-2)
Input voltage range 24 VDC -15% / +20%
Output current 0.2 A
Frequency See section "Inrush current behavior for output channels".
I/O and communication
Bus interface 0.4 W
Communication ports POWERLINK, Ethernet
Input type Sink
Mechanical
Mounting 35 mm DIN rail (IEC 60715)
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature 0...+55 °C (IEC 60068-2-1)
Certifications CE, UL, cULus

Values follow the B&R B&R X20 I/O module specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

B&R B&R X20 I/O module variants
Catalog number Breaking capacity Icu/Ics
X20SLX806 (this page) Type 1
X20SL8100 —
X20SL8101 Short-circuit proof, temporary overload
X20SL8110 —

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The X20SLX806 is the device-level element in a B&R circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for Industrial X20SLX806

Industrial X20SLX806 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number X20SLX806; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.

  • Enclosure rating: IP20 (IEC 60529) — Verify it in the project documentation before confirming the order.
  • Bus interface: 0.4 W — Check this value against the nameplate of the installed unit before ordering.
  • Input type: Sink — Match it to the existing panel and upstream protection.
  • Operating temperature: 0...+55 °C (IEC 60068-2-1) — Record it with the other nameplate data when sourcing a replacement.

Cross-check the ratings above with the installed device before confirming the order.

Common questions about X20SLX806

Q.Which value is published under mounting for catalog number X20SLX806?

For X20SLX806, mounting is given as 35 mm DIN rail (IEC 60715). Use the value as the reference when sourcing a current-production equivalent.

Q.Before ordering X20SLX806, which frequency entry should be checked?

The frequency entry quoted above is See section "Inrush current behavior for output channels".. Check the revision of the installed unit if the catalog number has been superseded.

Q.Where can I find the input type data for X20SLX806?

It is listed in the specification table for Industrial X20SLX806 as Sink. Compare it with the nameplate of the installed unit before ordering.

Q.Can the X20SLX806 replace the unit currently installed in my panel?

Compare catalog number X20SLX806 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.

Q.What should I include in an enquiry for X20SLX806?

Send the full catalog number X20SLX806, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Industrial X20SLX806.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!