B&R · B&R X20 I/O module
X20CP1485-1 is a B&R circuit breaker with Supply voltage 24 V DC (IEC 61131-2); Enclosure rating IP20 (IEC 60529). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Breaking capacity Icu/Ics-
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Supply voltage |
24 V DC (IEC 61131-2) |
| Input voltage range |
24 VDC -15% / +20% |
| Output current |
0.5 A |
| Power consumption |
10.5 W |
| Overload capacity |
Yes, using LED status indicator and software |
| I/O and communication |
| Bus interface |
1.42 W |
| Communication ports |
POWERLINK, Ethernet |
| Mechanical |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the B&R B&R X20 I/O module specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The X20CP1485-1 is the device-level element in a B&R circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial X20CP1485-1
Industrial X20CP1485-1 — PLC / CPU module used as the device-level control core in an automation panel, handling logic, timing and communication tasks. The figures below are taken from the specification table on this page for catalog number X20CP1485-1; verify the catalog number against your bill of materials before requesting a quotation.
- Power consumption: 10.5 W — Check this value against the nameplate of the installed unit before ordering.
- Overload capacity: Yes, using LED status indicator and software — Match it to the existing panel and upstream protection.
- Certifications: CE, UL, cULus — Record it with the other nameplate data when sourcing a replacement.
- Bus interface: 1.42 W — Confirm the revision of the installed unit before a like-for-like replacement.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about X20CP1485-1
Q.Where can I find the bus interface data for X20CP1485-1?
It is listed in the specification table for Industrial X20CP1485-1 as 1.42 W. Compare it with the nameplate of the installed unit before ordering.
Q.For X20CP1485-1, what does the specification table state about input voltage range?
The specification table lists input voltage range = 24 VDC -15% / +20% for Industrial X20CP1485-1. Confirm this figure against the unit currently in the panel.
Q.Which value is published under supply voltage for catalog number X20CP1485-1?
For X20CP1485-1, supply voltage is given as 24 V DC (IEC 61131-2). Use the value as the reference when sourcing a current-production equivalent.
Q.Can the X20CP1485-1 replace the unit currently installed in my panel?
Compare catalog number X20CP1485-1 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of X20CP1485-1 before ordering?
Match the catalog number X20CP1485-1 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.