B&R · B&R X20 I/O module
X20BT9300 is a B&R circuit breaker with Breaking capacity Icu/Ics Short-circuit proof, temporary overload; Supply voltage 24 V DC (IEC 61131-2); Enclosure rating IP20 (IEC 60529). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Breaking capacity Icu/IcsShort-circuit proof, temporary overload
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Breaking capacity Icu/Ics |
Short-circuit proof, temporary overload |
| Supply voltage |
24 V DC (IEC 61131-2) |
| Input voltage range |
24 VDC -15% / +20% |
| Overload capacity |
Yes, using LED status indicator and software |
| I/O and communication |
| Bus interface |
X2X Link bus receiver with supply for I/O and bus |
| Communication ports |
POWERLINK, Ethernet |
| Mechanical |
| Dimensions (H x W x D) |
1.0 (10/17/2005) |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the B&R B&R X20 I/O module specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| B&R B&R X20 I/O module variants |
| Catalog number |
Mounting |
|
X20BT9300 (this page) |
35 mm DIN rail (IEC 60715) |
| X20BT9100 |
35 mm DIN rail (IEC 60715) |
| X20BT9400 |
35 mm DIN rail (IEC 60715) |
| X20BC0088 |
DIN rail / panel |
All variants share the same B&R X20 I/O module footprint and terminal layout; the columns above show where they differ. Selecting a different catalog number changes the electrical interface, not the mounting.
Where it sits in the control system
The X20BT9300 is the device-level element in a B&R circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Before you specify
-
Trip curve. Select the tripping characteristic (trip curve) for the load profile; a C curve suits standard distribution, B suits long cable runs.
-
Breaking capacity. Confirm the installation's prospective fault current does not exceed Short-circuit proof, temporary overload; downstream coordination depends on it.
-
Poles. Match the pole count (pole count) to the circuit; mixing 1P and 3P in the same board is a wiring error.
-
Mounting. Verify the 35 mm DIN rail (IEC 60715) arrangement fits the existing DIN rail or panel cutout.
Technical FAQ
Q.What supply does this device require?
It requires 24 V DC (IEC 61131-2). Size the supply source to the same rating shown in the Specifications table.
Q.How is this device mounted?
It mounts by 35 mm DIN rail (IEC 60715). Confirm the cutout or rail before ordering a like-for-like spare.
Q.What is the operating temperature range?
The confirmed operating range is 0...+55 °C (IEC 60068-2-1). Panels running beyond it need derated sizing.
Q.What replaces a unit that is no longer in production?
For a like-for-like spare, record the catalog number and revision from the nameplate; a current-production equivalent is identified by matching function and ratings.