8V1180.00-2 is a B&R circuit breaker with Rated current Ie 12 A (fast-acting)Supply voltage 3-phase 200...480 V AC. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie12 A (fast-acting)
-
Breaking capacity Icu/IcsYes
-
Supply voltage3-phase 200...480 V AC
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated current Ie |
12 A (fast-acting) |
| Supply voltage |
3-phase 200...480 V AC |
| Input voltage range |
3x 400 VAC to 480 VAC ±10% |
| Output current |
Max. 0.5 A |
| Frequency |
50 / 60 Hz ±4% |
| Overload capacity |
150 % for 60 s |
| I/O and communication |
| Bus interface |
940 µF |
| Communication ports |
POWERLINK, Ethernet |
| Response time |
Approx. 250 mA |
| Mechanical |
| Weight |
10.1 kg |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the B&R ACOPOS servo drive specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 8V1180-00-2 is the device-level element in a B&R circuit breaker installation. It receives the field signals and control supply listed above — 3-phase 200...480 V AC — and switches or conditions the load within the 12 A (fast-acting) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides standard panel or DIN-rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial 8V1180.00-2
Industrial 8V1180.00-2 — Servo and motion-control component for high-accuracy positioning and synchronised movement. The figures below are taken from the specification table on this page for catalog number 8V1180.00-2; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Breaking capacity Icu/Ics: Yes — Match it to the existing panel and upstream protection.
- Input voltage range: 3x 400 VAC to 480 VAC ±10% — Record it with the other nameplate data when sourcing a replacement.
- Overload capacity: 150 % for 60 s — Confirm the revision of the installed unit before a like-for-like replacement.
- Rated current Ie: 12 A (fast-acting) — Use it as the reference when cross-checking a current-production equivalent.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about 8V1180.00-2
Q.For 8V1180.00-2, what does the specification table state about weight?
The specification table lists weight = 10.1 kg for Industrial 8V1180.00-2. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under rated current Ie for catalog number 8V1180.00-2?
For 8V1180.00-2, rated current Ie is given as 12 A (fast-acting). Compare it with the nameplate of the installed unit before ordering.
Q.Before ordering 8V1180.00-2, which bus interface entry should be checked?
The bus interface entry quoted above is 940 µF. Confirm this figure against the unit currently in the panel.
Q.Can the 8V1180.00-2 replace the unit currently installed in my panel?
Compare catalog number 8V1180.00-2 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of 8V1180.00-2 before ordering?
Match the catalog number 8V1180.00-2 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.