ABB · SACE Tmax XT

1SDA074744R1 is the ABB XT2N 125 TMA 100-500..1000 3p F F UL/CSA molded case circuit breaker: 3 poles, In = 100 A with a TMA thermal-magnetic adjustable trip unit, and fixed front (bolt-connected) terminals. It is used in UL489 panel feeders and distribution circuits where the installed unit is matched to the original catalog number.

  • Rated current In100 A
  • Trip unitTMA (thermal-magnetic)
  • Number of poles3 P
  • Rated operational voltage600 V AC / 500 V DC

Specifications

Electrical
Frame / family SACE Tmax XT, XT2N 125 (125 A frame), UL/CSA version
Rated current In 100 A (TMA overload setting 70...100 A)
Instantaneous setting Ii 500...1000 A
Rated operational voltage Ue 600 V AC / 500 V DC
Rated insulation voltage Ui 1000 V
Rated impulse withstand Uimp 8 kV
Breaking capacity Icu (UL489, AC) 65 kA @ 240 V AC; 25 kA @ 480 V AC; 18 kA @ 600 V AC
Breaking capacity (UL489, DC) 35 kA @ 250 V DC (2 poles in series); 35 kA @ 500 V DC (3 poles in series)
Short-circuit performance class N (IEC 60947-2: 36 kA @ 415 V AC)
Trip unit TMA thermal-magnetic, adjustable
Number of poles 3 (3P)
Mechanical
Terminals Fixed front terminals (F F), bolt connection, M6, tightening torque 6 N·m
Dimensions / weight 90 × 130 × 82.5 mm (W × H × D); 1.1 kg net
Compliance
Standards UL489 Listed, CSA certified (UL/CSA version); CE per EC Declaration of Conformity Tmax XT2
Enclosure rating IP20

Values follow the ABB SACE Tmax XT UL/CSA catalog for catalog number 1SDA074744R1 (XT2N 125 TMA 100-500..1000 3p F F UL/CSA). This breaker has no communication ports. Parameters not confirmed for this variant are omitted rather than estimated.

Where it sits in the control system

The 1SDA074744R1 is a UL489 molded case circuit breaker for feeder and branch protection at up to 600 V AC / 500 V DC, with an 18 kA (600 V AC) UL489 interrupting rating. Lugs and terminal accessories are sized to the bolt-type fixed front terminals, and the trip settings (70...100 A overload, 500...1000 A instantaneous) are coordinated with the downstream conductors, not to a generic assumption.

Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Before you specify

  • Trip unit. The TMA thermal-magnetic trip is adjustable: 70...100 A (overload) and 500...1000 A (instantaneous). Set it to the conductor and load profile.
  • Breaking capacity. Confirm the installation's prospective fault current does not exceed the UL489 rating at the application voltage: 65 kA @ 240 V AC, 25 kA @ 480 V AC, 18 kA @ 600 V AC.
  • Poles. This catalog number is a 3-pole (3P) breaker. For DC applications, poles are connected in series as required by the DC interrupting rating.
  • Terminals. Fixed front bolt-type terminals (F F); verify lug size and terminal cover accessories before ordering.

Technical FAQ

Q.What supply does this device require?

It is rated for 600 V AC / 500 V DC operational voltage (Ui 1000 V). Size the installation to the same ratings shown in the Specifications table.

Q.What are the key electrical ratings?

In = 100 A (TMA, 70...100 A adjustable), Ii = 500...1000 A, 3 poles, UL489 Icu 65 kA @ 240 V AC / 25 kA @ 480 V AC / 18 kA @ 600 V AC. Cross-check them against the installed unit's nameplate.

Q.How is this device mounted?

Fixed mounting with bolt-type front terminals (F F). It is not a 35 mm DIN-rail MCB; plan the panel or plate mounting space for the 90 × 130 × 82.5 mm body.

Q.Does this breaker have communication ports?

No. The TMA thermal-magnetic version has no communication capability; communication accessories apply to electronic-trip XT2 variants, not this catalog number.

Q.What replaces a unit that is no longer in production?

For a like-for-like spare, record the catalog number and revision from the nameplate; a current-production equivalent is identified by matching function and ratings.

Manufacturer reference

ABB catalog entry for 1SDA074744R1 identifies the XT2N 125 frame, 100 A TMA trip and three-pole UL/CSA configuration.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!