ABB · Tmax T2
T25DU65 is an ABB circuit breaker with Number of poles 3P / 4P (selectable); Rated operational voltage up to 690 V AC / 500 V DC; Breaking capacity Icu/Ics 25 kA at 400 V AC. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Number of poles3P / 4P (selectable)
-
Rated operational voltageup to 690 V AC / 500 V DC
-
Breaking capacity Icu/Ics25 kA at 400 V AC
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated operational voltage |
up to 690 V AC / 500 V DC |
| Rated insulation voltage Ui |
800 V |
| Rated impulse withstand Uimp |
8 kV |
| Breaking capacity Icu/Ics |
25 kA at 400 V AC |
| Number of poles |
3P / 4P (selectable) |
| I/O and communication |
| Communication ports |
Modbus, PROFINET, Ethernet |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, CSA, CCC |
Values follow the ABB Tmax T2 specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| ABB Tmax T2 variants |
| Catalog number |
Breaking capacity Icu/Ics |
Rated operational voltage |
|
T25DU65 (this page) |
25 kA at 400 V AC |
up to 690 V AC / 500 V DC |
| T2S160-TMD50-500 |
6 kA / 10 kA (IEC 60898) |
up to 690 V AC / 500 V DC |
All variants share the same Tmax T2 footprint and terminal layout; the columns above show where they differ. Selecting a different catalog number changes the electrical interface, not the mounting.
Where it sits in the control system
The T25DU65 is the device-level element in an ABB circuit breaker installation. It receives the field signals and control supply listed above — up to 690 V AC / 500 V DC — and switches or conditions the load within the up to 690 V AC / 500 V DC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Before you specify
-
Trip curve. Select the tripping characteristic (trip curve) for the load profile; a C curve suits standard distribution, B suits long cable runs.
-
Breaking capacity. Confirm the installation's prospective fault current does not exceed 25 kA at 400 V AC; downstream coordination depends on it.
-
Poles. Match the pole count (3P / 4P (selectable)) to the circuit; mixing 1P and 3P in the same board is a wiring error.
-
Mounting. Verify the DIN rail / panel arrangement fits the existing DIN rail or panel cutout.
Technical FAQ
Q.What supply does this device require?
It requires up to 690 V AC / 500 V DC. Size the supply source to the same rating shown in the Specifications table.
Q.What are the key electrical ratings?
The confirmed ratings include up to 690 V AC / 500 V DC and CE, UL, CSA, CCC marking. Cross-check them against the installed unit's nameplate.
Q.How is this device mounted?
It mounts by DIN rail / panel. Confirm the cutout or rail before ordering a like-for-like spare.
Q.What is the operating temperature range?
The confirmed operating range is 0...+55 °C (IEC 60068-2-1). Panels running beyond it need derated sizing.
Q.What replaces a unit that is no longer in production?
For a like-for-like spare, record the catalog number and revision from the nameplate; a current-production equivalent is identified by matching function and ratings.