ABB · ABB S200 / S201 / S202 / S203 / S204

2CDS271001R0065 is an ABB circuit breaker with Rated current Ie 0.5-63 A (order-code dependent); Tripping characteristic B / C / D (IEC 60898); Number of poles 1 / 2 / 3 / 4 (IEC 60898). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Rated current Ie0.5-63 A (order-code dependent)
  • Tripping characteristicB / C / D (IEC 60898)
  • Number of poles1 / 2 / 3 / 4 (IEC 60898)
  • Rated operational voltage230/400 V AC

Specifications

Electrical
Rated current Ie 0.5-63 A (order-code dependent)
Rated operational voltage 230/400 V AC
Rated insulation voltage Ui 440 V (IEC 60947-2)
Rated impulse withstand Uimp 4 kV (IEC 60947-2)
Breaking capacity Icu/Ics 6 kA / 10 kA (IEC 60898)
Tripping characteristic B / C / D (IEC 60898)
Number of poles 1 / 2 / 3 / 4 (IEC 60898)
I/O and communication
Communication ports Modbus, PROFINET, Ethernet
Mechanical
Mounting 35 mm DIN rail (IEC 60715)
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature -25...+60 °C (IEC 60068-2-1)
Certifications CE, UL, CSA, CCC

Values follow the ABB ABB S200 / S201 / S202 / S203 / S204 specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

ABB ABB S200 / S201 / S202 / S203 / S204 variants
Catalog number Tripping characteristic Breaking capacity Icu/Ics Rated operational voltage
2CDS271001R0065 (this page) B / C / D (IEC 60898) 6 kA / 10 kA (IEC 60898) 230/400 V AC
2CDS271001R0104 B / C / D (IEC 60898) 6 kA / 10 kA (IEC 60898) 230/400 V AC
2CDS271061R0044 B / C / D (IEC 60898) 6 kA / 10 kA (IEC 60898) 230/400 V AC
2CDS271337R0427 B / C / D (IEC 60898) 6 kA / 10 kA (IEC 60898) 230/400 V AC

All variants share the same ABB S200 / S201 / S202 / S203 / S204 footprint and terminal layout; the columns above show where they differ. Selecting a different catalog number changes the electrical interface, not the mounting.

Where it sits in the control system

The 2CDS271001R0065 is the device-level element in an ABB circuit breaker installation. It receives the field signals and control supply listed above — 230/400 V AC — and switches or conditions the load within the 0.5-63 A (order-code dependent) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Before you specify

  • Trip curve. Select the tripping characteristic (B / C / D (IEC 60898)) for the load profile; a C curve suits standard distribution, B suits long cable runs.
  • Breaking capacity. Confirm the installation's prospective fault current does not exceed 6 kA / 10 kA (IEC 60898); downstream coordination depends on it.
  • Poles. Match the pole count (1 / 2 / 3 / 4 (IEC 60898)) to the circuit; mixing 1P and 3P in the same board is a wiring error.
  • Mounting. Verify the 35 mm DIN rail (IEC 60715) arrangement fits the existing DIN rail or panel cutout.

Technical FAQ

Q.What supply does this device require?

It requires 230/400 V AC. Size the supply source to the same rating shown in the Specifications table.

Q.What are the key electrical ratings?

The confirmed ratings include 0.5-63 A (order-code dependent) and CE, UL, CSA, CCC marking. Cross-check them against the installed unit's nameplate.

Q.How is this device mounted?

It mounts by 35 mm DIN rail (IEC 60715). Confirm the cutout or rail before ordering a like-for-like spare.

Q.What is the operating temperature range?

The confirmed operating range is -25...+60 °C (IEC 60068-2-1). Panels running beyond it need derated sizing.

Q.What replaces a unit that is no longer in production?

For a like-for-like spare, record the catalog number and revision from the nameplate; a current-production equivalent is identified by matching function and ratings.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!