ABB

ABB N40E 1SBH141001R8040 Contactor Relay

SKU: 1SBH141001R8040
Regular price $43.99
In stock (96 units)
Condition
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

ABB product — N40E

-->

Product identification

  • Model: N40E
  • Global material number: 1SBH141001R8040

Source: ABB official product data (dealer mirror: santaclarasystems.com)

Evidence URL: https://www.santaclarasystems.com/abb/1sbh141001r8040

Technical specifications

Source: ABB official product data (dealer mirror: santaclarasystems.com) — https://www.santaclarasystems.com/abb/1sbh141001r8040

Technical

Product ID 1SBH141001R8040
Extended Product Type 1SBH141001R8040
Product Net Weight 0.340 kg
Product Net Width 44 mm
Product Net Height 74 mm
Product Net Depth 74 mm
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Ambient Air Temperature Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C Close to Contactor for Storage -60 ... +80 °C
Standards Devices complying with international standards IEC 947-5-1 / 947-4-1 and European standards EN 60 947-5-1 / 60 947-4-1. Electromagnetic compatibility (EMC) according to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Impulse Withstand Voltage (Uimp) 8 kV
Rated Insulation Voltage (Ui) acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
Terminal Type Screw Terminals
Rated Frequency (f) Supply Circuit 50 Hz Supply Circuit 60 Hz
Number of Auxiliary Contacts NO 4
Number of Auxiliary Contacts NC 0
GOST Certificate GOST_POCCFRME01B03022
Maximum Operating Altitude Permissible 3000 m
Rated Control Circuit Voltage (Uc) 50 Hz 220 … 230 V 60 Hz 230 … 240 V
Climatic Withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Mechanical Switching Frequency 6000 cycles per hour
Connecting Capacity Auxiliary Circuit Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
Operate Time Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
GL Certificate DNV-GL_TAE00000TY
Short-Circuit Protective Devices gG Type Fuses 10 A
Coil Operating Limits (acc. to IEC 60947-5-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
EAN 3471522012807
Rated Operational Voltage Main Circuit 690 V
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-15 (Ie) (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
Rated Short-time Withstand Current (Icw) for 0.1 s 140 A for 1 s 100 A
Rated Operational Current DC-13 (Ie) (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
Resistance to Shock acc. to IEC 60068-2-27 Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
Instructions and Manuals FPTC407721P0001
BV Certificate BV_2634H09651C0
CB Certificate CB_FR_602227B
CCC Certificate CCC_2003010304088235
cUL Certificate UL_110105E48139A
Data Sheet, Technical Information 1SBC100122C0202_Ch03
Declaration of Conformity - CE 1SBD250808U1000
DNV Certificate DNV-GL_TAE00000TY
LR Certificate LRS_9830010E2
RINA Certificate RINA_ELE128713XG002
RMRS Certificate RMRS_0507015250
UNSPSC 39121500
Object Classification Code K

Frequently asked questions

What is the rated supply voltage?

8 kV

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Impulse Withstand Voltage (Uimp)" (https://www.santaclarasystems.com/abb/1sbh141001r8040)

What is the rated current?

acc. to IEC 60947-5-1, q = 40 °C 16 A

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Conventional Free-air Thermal Current (Ith)" (https://www.santaclarasystems.com/abb/1sbh141001r8040)

How many poles / contacts does it have?

4

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Number of Auxiliary Contacts NO" (https://www.santaclarasystems.com/abb/1sbh141001r8040)

What is the rated frequency?

Supply Circuit 50 Hz Supply Circuit 60 Hz

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Frequency (f)" (https://www.santaclarasystems.com/abb/1sbh141001r8040)

What is the degree of protection?

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Degree of Protection" (https://www.santaclarasystems.com/abb/1sbh141001r8040)

What is the product weight?

0.340 kg

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Product Net Weight" (https://www.santaclarasystems.com/abb/1sbh141001r8040)

-->

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. Express shipping is a fixed USD 50.00 for eligible destinations in the United States and Canada.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date the order is placed (order date), against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!