ABB product — AF80-30-00-13
-->
Product identification
- Model: AF80-30-00-13
- Global material number: 1SBL397001R1300
Source: ABB Product Information System (PIS) - official ABB product data
Evidence URL: https://www.abb.com/global/en/products/1sbl397001r1300
Technical specifications
Source: ABB Product Information System (PIS) - official ABB product data — https://www.abb.com/global/en/products/1sbl397001r1300
Ordering
| Minimum Order Quantity |
1 piece |
| Customs Tariff Number |
85364900 |
Dimensions
| Product Net Width |
70 mm |
| Product Net Depth / Length |
116 mm |
| Product Net Height |
125.5 mm |
| Product Net Weight |
1.17 kg |
Technical
| Number of Main Contacts NO |
3 |
| Number of Main Contacts NC |
0 |
| Number of Auxiliary Contacts NO |
0 |
| Number of Auxiliary Contacts NC |
0 |
| Number of Poles |
3P |
| Standards |
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22 |
| Rated Operational Voltage |
Main Circuit 1000 V |
| Rated Frequency (f) |
Control Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) |
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A |
| Rated Operational Current AC-1 (Ie) |
(690 V) 40 °C 125 A |
| Rated Operational Current AC-3 (Ie) |
(415 V) 60 °C 80 A |
| Rated Operational Current AC-3e (Ie) |
(415 V) 60 °C 80 A |
| Rated Operational Current DC-1 (Ie) |
(110 V) 2 Poles in Series, 40 °C 125 A |
| Rated Operational Current DC-3 (Ie) |
(110 V) 2 Poles in Series, 40 °C 125 A |
| Rated Operational Current DC-5 (Ie) |
(110 V) 2 Poles in Series, 40 °C 125 A |
| Rated Operational Power AC-3 (Pe) |
(400 V) 37 kW |
| Rated Operational Power AC-3e (Pe) |
(415 V) 45 kW |
| Rated Short-time Withstand Current Low Voltage (Icw) |
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A |
| Maximum Breaking Capacity |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A |
| Rated Insulation Voltage (Ui) |
acc. to IEC 60947-4-1 1000 V |
| Rated Impulse Withstand Voltage (Uimp) |
8 kV |
| Maximum Electrical Switching Frequency |
(AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency |
3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) |
50 Hz 100 ... 250 V |
| Coil Consumption |
Average Holding Value 50 / 60 Hz 4 V·A |
| Power Loss |
at Rated Operating Conditions AC-1 per Pole 7.6 W |
| Operate Time |
Between Coil De-energization and NC Contact Closing 19 ... 105 ms |
| Mounting on DIN Rail |
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) |
2 x M4 or 2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit |
Flexible with Ferrule 1/2x 6 ... 50 mm² |
| Connecting Capacity Control Circuit |
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Wire Stripping Length |
Control Circuit 10 mm |
| Degree of Protection |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Recommended Screw Driver |
Pozidriv PZ |
| Tightening Torque |
Control Circuit 1.2 N·m |
| Terminal Type |
Screw Terminals |
| Product Name |
Block Contactor |
Environmental
| Ambient Air Temperature |
Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C |
| Climatic Withstand |
Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible |
Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 |
Closed, Shock Direction: A 25 g |
| Resistance to Vibrations |
3g Closed Position & 3g Open Position 5 ... 300 Hz |
| Pollution Degree |
3 |
Container Information
| Package Level 1 Units |
box 1 piece |
| Package Level 1 Width |
150 mm |
| Package Level 1 Depth / Length |
150 mm |
| Package Level 1 Height |
103 mm |
| Package Level 1 Gross Weight |
1.29 kg |
| Package Level 1 EAN |
3471523132931 |
Frequently asked questions
What is the rated supply voltage?
Main Circuit 1000 V
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Operational Voltage" (https://www.abb.com/global/en/products/1sbl397001r1300)
What is the rated current?
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Source: ABB Product Information System (PIS) - official ABB product data, field "Conventional Free-air Thermal Current (Ith)" (https://www.abb.com/global/en/products/1sbl397001r1300)
How many poles / contacts does it have?
3
Source: ABB Product Information System (PIS) - official ABB product data, field "Number of Main Contacts NO" (https://www.abb.com/global/en/products/1sbl397001r1300)
What is the rated frequency?
Control Circuit 50 / 60 Hz
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Frequency (f)" (https://www.abb.com/global/en/products/1sbl397001r1300)
What is the degree of protection?
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Source: ABB Product Information System (PIS) - official ABB product data, field "Degree of Protection" (https://www.abb.com/global/en/products/1sbl397001r1300)
What is the power rating?
(400 V) 37 kW
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Operational Power AC-3 (Pe)" (https://www.abb.com/global/en/products/1sbl397001r1300)
-->