ABB product — AF63-30-11 48-130V 50Hz / 48-130V 60Hz / 48-130V DC
-->
Product identification
- Model: AF63-30-11 48-130V 50Hz / 48-130V 60Hz / 48-130V DC
- Global material number: 1SBL377001R6911
Source: ABB Product Information System (PIS) - official ABB product data
Evidence URL: https://www.abb.com/global/en/products/1sbl377001r6911
Technical specifications
Source: ABB Product Information System (PIS) - official ABB product data — https://www.abb.com/global/en/products/1sbl377001r6911
Ordering
| Minimum Order Quantity |
1 piece |
| Customs Tariff Number |
85364900 |
Dimensions
| Product Net Width |
82 mm |
| Product Net Depth / Length |
108 mm |
| Product Net Height |
110 mm |
| Product Net Weight |
1.22 kg |
Technical
| Number of Main Contacts NO |
3 |
| Number of Main Contacts NC |
0 |
| Number of Auxiliary Contacts NO |
1 |
| Number of Auxiliary Contacts NC |
1 |
| Number of Poles |
3P |
| Rated Operational Voltage |
Auxiliary Circuit 690 V |
| Rated Frequency (f) |
Auxiliary Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) |
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A |
| Rated Operational Current AC-1 (Ie) |
(690 V) 40 °C 115 A |
| Rated Operational Current AC-3 (Ie) |
(415 V) 55 °C 65 A |
| Rated Operational Current AC-15 (Ie) |
(500 V) 2 A |
| Rated Operational Current DC-1 (Ie) |
(110 V) 2 Poles in Series, 40 °C 110 A |
| Rated Operational Current DC-3 (Ie) |
(110 V) 2 Poles in Series, 40 °C 110 A |
| Rated Operational Current DC-5 (Ie) |
(110 V) 2 Poles in Series, 40 °C 90 A |
| Rated Operational Current DC-13 (Ie) |
(24 V) 6 A / 144 W |
| Rated Operational Power AC-3 (Pe) |
(415 V) 37 kW |
| Rated Operational Power AC-6b (Pe) |
(230 / 240 V) 40 °C, 50 / 60 Hz 25 kvar |
| Short-Circuit Protective Devices |
Auxiliary Circuit - gG Type Fuses 10 A |
| Rated Short-time Withstand Current Low Voltage (Icw) |
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A |
| Maximum Breaking Capacity |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A |
| Rated Insulation Voltage (Ui) |
acc. to IEC 60947-4-1 1000 V |
| Rated Impulse Withstand Voltage (Uimp) |
8 kV |
| Maximum Electrical Switching Frequency |
(AC-1) 300 cycles per hour |
| Mechanical Durability |
10 million |
| Maximum Mechanical Switching Frequency |
300 cycles per hour |
| Minimum Switching Capacity |
17 / 5 VLT4K |
| Rated Control Circuit Voltage (Uc) |
50 Hz 48 ... 130 V |
| Coil Consumption |
Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A |
| Power Loss |
at Rated Operating Conditions per Pole 0.1 W |
| Operate Time |
Between Coil De-energization and NC Contact Closing 35 ... 115 ms |
| Mounting on DIN Rail |
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| Mounting by Screws (not supplied) |
2 x M6 Screws Placed Diagonally |
| Connecting Capacity Main Circuit |
Flexible with Cable End 6 ... 16 mm² |
| Connecting Capacity Auxiliary Circuit |
Flexible with Cable End 0.75 ... 2.5 mm² |
| Degree of Protection |
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 |
| Terminal Type |
Screw Terminals |
| Product Name |
Block Contactor |
Environmental
| Ambient Air Temperature |
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C |
| Maximum Operating Altitude Permissible |
Without Derating 3000 m |
| Shock and Vibration Withstand acc. to IEC 61373 |
Category 1, Class B |
| Pollution Degree |
3 |
Container Information
| Package Level 1 Units |
box 1 piece |
| Package Level 1 Width |
140 mm |
| Package Level 1 Depth / Length |
146 mm |
| Package Level 1 Height |
96 mm |
| Package Level 1 Gross Weight |
1.22 kg |
| Package Level 1 EAN |
3471522115096 |
Frequently asked questions
What is the rated supply voltage?
Auxiliary Circuit 690 V
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Operational Voltage" (https://www.abb.com/global/en/products/1sbl377001r6911)
What is the rated current?
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 125 A
Source: ABB Product Information System (PIS) - official ABB product data, field "Conventional Free-air Thermal Current (Ith)" (https://www.abb.com/global/en/products/1sbl377001r6911)
How many poles / contacts does it have?
3
Source: ABB Product Information System (PIS) - official ABB product data, field "Number of Main Contacts NO" (https://www.abb.com/global/en/products/1sbl377001r6911)
What is the rated frequency?
Auxiliary Circuit 50 / 60 Hz
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Frequency (f)" (https://www.abb.com/global/en/products/1sbl377001r6911)
What is the degree of protection?
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
Source: ABB Product Information System (PIS) - official ABB product data, field "Degree of Protection" (https://www.abb.com/global/en/products/1sbl377001r6911)
What is the power rating?
(415 V) 37 kW
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Operational Power AC-3 (Pe)" (https://www.abb.com/global/en/products/1sbl377001r6911)
-->