ABB product — AF210-30-11-70
-->
Product identification
- Model: AF210-30-11-70
- Global material number: 1SFL517001R7011
Source: PLC Direct (third-party listing of ABB official product data)
Evidence URL: https://plc-direct.com/products/1sfl517001r7011
Technical specifications
Source: PLC Direct (third-party listing of ABB official product data) — https://plc-direct.com/products/1sfl517001r7011
Dimensions
| Product Net Width |
140 mm |
| Product Net Depth / Length |
180.5 mm |
| Product Net Height |
227 mm |
| Product Net Weight |
5.05 kg |
Technical
| Number of Main Contacts NO |
3 |
| Number of Main Contacts NC |
0 |
| Number of Auxiliary Contacts NO |
1 |
| Number of Auxiliary Contacts NC |
1 |
| Number of Poles |
3P |
| Rated Operational Voltage |
Main Circuit 690 V |
| Rated Frequency (f) |
Main Circuit 50 / 60 Hz |
| Rated Breaking Capacity AC-3 |
8 x Ie AC-3 |
| Rated Making Capacity AC-3 |
10 x Ie AC-3 |
| Short-Circuit Protective Devices |
gG Type Fuses 400 A |
| Maximum Breaking Capacity |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2200 A |
| Maximum Electrical Switching Frequency |
(AC-1) 300 cycles per hour |
| Mechanical Durability |
5 million |
| Maximum Mechanical Switching Frequency |
300 cycles per hour |
| Coil Operating Limits |
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Coil Consumption |
Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V·A |
| Power Loss |
at Rated Operating Conditions per Pole 9 W |
| Operate Time |
Between Coil De-energization and NC Contact Closing 40 .... 50 ms |
| Connecting Capacity Main Circuit |
Bar 32 mm² |
| Connecting Capacity Auxiliary Circuit |
Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Connecting Capacity |
Bar 32 mm² |
| Degree of Protection |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Tightening Torque |
Main Circuit 18 N·m |
| Terminal Type |
Main Circuit: Bars |
| Product Name |
Block Contactor |
Environmental
| Ambient Air Temperature |
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Maximum Operating Altitude Permissible |
Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 |
Shock Direction: A 5 g |
Frequently asked questions
What is the rated supply voltage?
Main Circuit 690 V
Source: PLC Direct (third-party listing of ABB official product data), field "Rated Operational Voltage" (https://plc-direct.com/products/1sfl517001r7011)
How many poles / contacts does it have?
3
Source: PLC Direct (third-party listing of ABB official product data), field "Number of Main Contacts NO" (https://plc-direct.com/products/1sfl517001r7011)
What is the rated frequency?
Main Circuit 50 / 60 Hz
Source: PLC Direct (third-party listing of ABB official product data), field "Rated Frequency (f)" (https://plc-direct.com/products/1sfl517001r7011)
What is the degree of protection?
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Source: PLC Direct (third-party listing of ABB official product data), field "Degree of Protection" (https://plc-direct.com/products/1sfl517001r7011)
What is the power rating?
at Rated Operating Conditions per Pole 9 W
Source: PLC Direct (third-party listing of ABB official product data), field "Power Loss" (https://plc-direct.com/products/1sfl517001r7011)
What is the product weight?
5.05 kg
Source: PLC Direct (third-party listing of ABB official product data), field "Product Net Weight" (https://plc-direct.com/products/1sfl517001r7011)
-->