ABB product — AF1250-30-11-70
-->
Product identification
- Model: AF1250-30-11-70
- Global material number: 1SFL647001R7011
Source: ABB Product Information System (PIS) - official ABB product data
Evidence URL: https://www.abb.com/global/en/products/1sfl647001r7011
Product description
AF1250-30-11 100-250V 50/60Hz / 100-250V DC Contactor
Technical specifications
Source: ABB Product Information System (PIS) - official ABB product data — https://www.abb.com/global/en/products/1sfl647001r7011
Ordering
| Minimum Order Quantity |
1 piece |
| Customs Tariff Number |
85364900 |
Dimensions
| Product Net Width |
210 mm |
| Product Net Depth / Length |
242 mm |
| Product Net Height |
344 mm |
| Product Net Weight |
14.6 kg |
Technical
| Number of Main Contacts NO |
3 |
| Number of Main Contacts NC |
0 |
| Number of Auxiliary Contacts NO |
1 |
| Number of Auxiliary Contacts NC |
1 |
| Number of Poles |
3P |
| Rated Operational Voltage |
Main Circuit 1000 V |
| Rated Frequency (f) |
Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) |
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A |
| Rated Operational Current AC-1 (Ie) |
(1000 V) 40 °C 1260 A |
| Rated Operational Current DC-1 (Ie) |
(220 V) 3 Poles in Series, 40 °C 1250 A |
| Rated Operational Current DC-3 (Ie) |
(220 V) 3 Poles in Series, 40 °C 1250 A |
| Rated Operational Current DC-5 (Ie) |
(220 V) 3 Poles in Series, 40 °C 1250 A |
| Rated Breaking Capacity AC-3 |
8 x Ie AC-3 |
| Rated Making Capacity AC-3 |
10 x Ie AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) |
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1500 A |
| Maximum Breaking Capacity |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A |
| Rated Insulation Voltage (Ui) |
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| Rated Impulse Withstand Voltage (Uimp) |
Main Circuit 8 kV |
| Maximum Electrical Switching Frequency |
(AC-1) 300 cycles per hour |
| Mechanical Durability |
0.5 million |
| Maximum Mechanical Switching Frequency |
300 cycles per hour |
| Coil Operating Limits |
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) |
50 Hz 100 ... 250 V |
| Coil Consumption |
Holding at Max. Rated Control Circuit Voltage 50 Hz 38.3 V·A |
| Power Loss |
at Rated Operating Conditions AC-1 per Pole 91 W |
| Operate Time |
Between Coil De-energization and NC Contact Closing 50 ... 70 ms |
| Connecting Capacity Main Circuit |
Bar 50 mm² |
| Connecting Capacity Auxiliary Circuit |
Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Connecting Capacity |
Bar 50 mm² |
| Degree of Protection |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Connecting Terminals (delivered in open position) Main Poles |
M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver |
Main Circuit M12 |
| Tightening Torque |
Cable Lug 45 N·m |
| Terminal Type |
Main Circuit: Bars |
| Suitable for Product Class |
Block ContactorsBlock Contactors |
| Product Name |
Block Contactor |
Environmental
| Ambient Air Temperature |
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Maximum Operating Altitude Permissible |
Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 |
Shock Direction: A 5 g |
Container Information
| Package Level 1 Units |
box 1 piece |
| Package Level 1 Width |
280 mm |
| Package Level 1 Depth / Length |
375 mm |
| Package Level 1 Height |
310 mm |
| Package Level 1 Gross Weight |
16 kg |
| Package Level 1 EAN |
7320500355091 |
Frequently asked questions
What is the rated supply voltage?
Main Circuit 1000 V
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Operational Voltage" (https://www.abb.com/global/en/products/1sfl647001r7011)
What is the rated current?
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Source: ABB Product Information System (PIS) - official ABB product data, field "Conventional Free-air Thermal Current (Ith)" (https://www.abb.com/global/en/products/1sfl647001r7011)
How many poles / contacts does it have?
3
Source: ABB Product Information System (PIS) - official ABB product data, field "Number of Main Contacts NO" (https://www.abb.com/global/en/products/1sfl647001r7011)
What is the rated frequency?
Main Circuit 50 / 60 Hz
Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Frequency (f)" (https://www.abb.com/global/en/products/1sfl647001r7011)
What is the degree of protection?
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Source: ABB Product Information System (PIS) - official ABB product data, field "Degree of Protection" (https://www.abb.com/global/en/products/1sfl647001r7011)
What is the power rating?
at Rated Operating Conditions AC-1 per Pole 91 W
Source: ABB Product Information System (PIS) - official ABB product data, field "Power Loss" (https://www.abb.com/global/en/products/1sfl647001r7011)
-->