Product identification
-
Model: ACS580-07-0363A-4
-
Global material number: ACS580-07-0363A-4
Product description
LV AC Cabinet-built single drives, UL: Pld 300 Hp, 361 A, 480 V (ACS580-07-0363A-4)
Source: ABB official product page
Technical specifications
Source: ABB Catalogue ACS580-PHTC01U-EN
Technical data
| ACS580-07: 200 to 700HP |
-15+50°C. (Technical data)
|
| Auto-identification of supply voltage |
R1to R9from+40to+50°C with derating (Technical data)
|
| Frequency / From 47 to 63 Hz |
R10 to R11 from +40 to +55 °C with derating (Technical data)
|
| Power factor / cosϕ = 0.98 |
0 to +40 °C. No frost allowed (Technical data)
|
| Efficiency / 98% |
R6 to R11 from +40 to +50 °C with derating (Technical data)
|
| (at nominal power) |
Cooling method (Technical data)
|
| (IEC 61800-9-2) |
Altitude 0 to 1,000 m Without derating (Technical data)
|
| Motor connection |
1,000 to 4,000 m With derating of 1%/100 m (Technical data)
|
| Voltage / 0 to U1, 3-phase |
For more detailed information please see the ACS580 (Technical data)
|
| Frequency / 0 to 500 Hz |
hardware manual (Technical data)
|
| Motor control / Scalar and vector control |
Relative humidity 5 to 95%, no condensation allowed (Technical data)
|
| Non-linearity: ± 5% with nominal torque |
UL (NEMA) Type 1 / IP21 as standard UL(NEMA)Type12/IP55 (frames R1to R9) (Technical data)
|
| Speed control / Static accuracy:20%of motor nominal slip |
as option UL(NEMA)Type4X/IP66as option(frames R1to R3) (Technical data)
|
| p p 2 analog inputs / ( g ) Selection of Current/Voltage input mode is user |
R1-R5 (Technical data)
|
Additional data
| F&B industry |
ABB (Food and beverage domain expertise)
|
| interfaces. In addition, the drive has two option slots that can be used for extensions, including / Terminal |
Meaning Default macro connections (Standard interface and extensions for plug-in connectivity)
|
| fieldbus adapters and input/output extension / XI |
Reference voltage and analog inputs and outputs (Standard interface and extensions for plug-in connectivity)
|
| modules that allow an external +24 V supply / 1 |
SCR Signal cable shield (screen) (Standard interface and extensions for plug-in connectivity)
|
| with frame sizes R1 to R5. For frames R6-R11 / 2 |
AI1 External frequency reference 1: 0 to 10 V (Standard interface and extensions for plug-in connectivity)
|
| external +24 V terminals are already integrated / 3 |
AGND Analog input circuit common (Standard interface and extensions for plug-in connectivity)
|
| on the control board. For further information, kohm / 4 |
+10 V Output reference voltage 10 V DC (Standard interface and extensions for plug-in connectivity)
|
| 1 to 10 please see the ACS580 user manual. / 5 |
AI2 Not used (Standard interface and extensions for plug-in connectivity)
|
| 1 2 / 8 |
AO2 Output current: 0 to 20 m A (Standard interface and extensions for plug-in connectivity)
|
| 3 / 10 |
+24 V Auxiliary voltage output +24 V DC (Standard interface and extensions for plug-in connectivity)
|
| 11 |
DGND Auxiliary voltage output common (Standard interface and extensions for plug-in connectivity)
|
| 4 / 12 |
DCOM Digital input common for all DI (Standard interface and extensions for plug-in connectivity)
|
Frequently asked questions
Q: What is the ACS580-07-0363A-4?
A: LV AC Cabinet-built single drives, UL: Pld 300 Hp, 361 A, 480 V (ACS580-07-0363A-4) (ABB official product page)
Q: How many channels or slots does it provide?
A: Meaning Default macro connections (Datasheet ACS580-PHTC01U-EN, Standard interface and extensions for plug-in connectivity)
Q: What is the rated supply voltage?
A: R1to R9from+40to+50°C with derating (Datasheet ACS580-PHTC01U-EN, Technical data)
Q: What interfaces does it offer?
A: Meaning Default macro connections (Datasheet ACS580-PHTC01U-EN, Standard interface and extensions for plug-in connectivity)
Q: Which standards or approvals does it comply with?
A: Altitude 0 to 1,000 m Without derating (Datasheet ACS580-PHTC01U-EN, Technical data)