ABB · ACS380
ACS380-040S-03A3-4 is an ABB industrial component with Rated current Ie 3.3 A; Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie3.3 A
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
Specifications
| Electrical |
| Rated current Ie |
3.3 A |
| Input voltage range |
380 ... 480 V |
| Frequency |
50/60 Hz |
| I/O and communication |
| Bus interface |
ABB FPBA-01 / FENA-21 / FECA-01 / FCAN-01 (adapter module) |
| Communication ports |
Modbus, PROFINET, Ethernet |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, CSA, CCC |
Values follow the ABB ACS380 specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
All variants share the same ACS380 footprint and terminal layout; the columns above show where they differ. Selecting a different catalog number changes the electrical interface, not the mounting.
Where it sits in the control system
The ACS380-040S-03A3-4 is the device-level element in an ABB industrial component installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the 3.3 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Before you specify
-
Ratings. Confirm the rated current and voltage match the circuit before specifying; sizing from the nameplate avoids field mismatch.
-
Mounting. Check the DIN rail / panel fit against the existing enclosure before ordering.
-
Marking. Record the catalog number and revision from the nameplate of the installed unit for a like-for-like spare.
Technical FAQ
Q.What supply does this device require?
See the Specifications table for the confirmed supply rating; size the source to that value.
Q.What are the key electrical ratings?
The confirmed ratings include 3.3 A and CE, UL, CSA, CCC marking. Cross-check them against the installed unit's nameplate.
Q.How is this device mounted?
It mounts by DIN rail / panel. Confirm the cutout or rail before ordering a like-for-like spare.
Q.What is the operating temperature range?
The confirmed operating range is 0...+55 °C (IEC 60068-2-1). Panels running beyond it need derated sizing.
Q.What replaces a unit that is no longer in production?
For a like-for-like spare, record the catalog number and revision from the nameplate; a current-production equivalent is identified by matching function and ratings.