ABB

ABB A145-30-11-84 1SFL471001R8411 Contactor

SKU: 1SFL471001R8411
Regular price $753.64
In stock (69 units)
Condition
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

ABB product — A145-30-11-84

-->

Product identification

  • Model: A145-30-11-84
  • Global material number: 1SFL471001R8411

Source: ABB Product Information System (PIS) - official ABB product data

Evidence URL: https://www.abb.com/global/en/products/1sfl471001r8411

Technical specifications

Source: ABB Product Information System (PIS) - official ABB product data — https://www.abb.com/global/en/products/1sfl471001r8411

Ordering

Minimum Order Quantity 1 piece
Customs Tariff Number 85364900
Replacement Product ID (NEW) 1SFL447002R1311

Dimensions

Product Net Width 111.5 mm
Product Net Depth / Length 160 mm
Product Net Height 196 mm
Product Net Weight 2.9 kg
Dimension Diagram 53540923-7.PDF

Technical

Number of Main Contacts NO 3
Number of Main Contacts NC 0
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 1
Number of Poles 3P
Rated Operational Voltage Main Circuit 690 V
Rated Frequency (f) Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie) (1000 V) 40 °C 180 A
Rated Operational Current AC-3 (Ie) (415 V) 55 °C 145 A
Rated Operational Current DC-1 (Ie) (110 V) 2 Poles in Series, 40 °C 250 A
Rated Operational Current DC-3 (Ie) (110 V) 2 Poles in Series, 40 °C 250 A
Rated Operational Current DC-5 (Ie) (110 V) 2 Poles in Series, 40 °C 250 A
Rated Operational Power AC-3 (Pe) (415 V) 75 kW
Rated Breaking Capacity AC-3 8 x Ie AC-3
Rated Making Capacity AC-3 10 x Ie AC-3
Short-Circuit Protective Devices gG Type Fuses 315 A
Rated Short-time Withstand Current Low Voltage (Icw) at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Impulse Withstand Voltage (Uimp) Main Circuit 8 kV
Maximum Electrical Switching Frequency (AC-1) 300 cycles per hour
Mechanical Durability 5 million
Maximum Mechanical Switching Frequency 3600 cycles per hour
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc) 50 Hz 110 V
Coil Consumption Average Holding Value, from Warm State 12.5 W
Power Loss at Rated Operating Conditions per Pole 5 W
Operate Time Between Coil De-energization and NC Contact Closing 5 ... 10 ms
Connecting Capacity Main Circuit Bar 24 mm²
Connecting Capacity Auxiliary Circuit Flexible with Ferrule 2x 0.75 ... 2.5 mm²
Connecting Capacity Bar 24 mm²
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Connecting Terminals (delivered in open position) Main Poles Flat type c/w screws and bolts
Tightening Torque Main Circuit 18 N·m
Terminal Type Main Circuit: Bars
Product Name Block Contactor

Environmental

Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Maximum Operating Altitude Permissible Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27 Shock Direction: A 5 g

Container Information

Package Level 1 Units box 1 piece
Package Level 1 Width 178 mm
Package Level 1 Depth / Length 232 mm
Package Level 1 Height 167 mm
Package Level 1 Gross Weight 3.5 kg
Package Level 1 EAN 7320500203293

Frequently asked questions

What is the rated supply voltage?

Main Circuit 690 V

Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Operational Voltage" (https://www.abb.com/global/en/products/1sfl471001r8411)

What is the rated current?

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A

Source: ABB Product Information System (PIS) - official ABB product data, field "Conventional Free-air Thermal Current (Ith)" (https://www.abb.com/global/en/products/1sfl471001r8411)

How many poles / contacts does it have?

3

Source: ABB Product Information System (PIS) - official ABB product data, field "Number of Main Contacts NO" (https://www.abb.com/global/en/products/1sfl471001r8411)

What is the rated frequency?

Main Circuit 50 / 60 Hz

Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Frequency (f)" (https://www.abb.com/global/en/products/1sfl471001r8411)

What is the degree of protection?

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

Source: ABB Product Information System (PIS) - official ABB product data, field "Degree of Protection" (https://www.abb.com/global/en/products/1sfl471001r8411)

What is the power rating?

(415 V) 75 kW

Source: ABB Product Information System (PIS) - official ABB product data, field "Rated Operational Power AC-3 (Pe)" (https://www.abb.com/global/en/products/1sfl471001r8411)

-->

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. Express shipping is a fixed USD 50.00 for eligible destinations in the United States and Canada.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date the order is placed (order date), against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!