ABB

ABB A12-30-10 1SBL161001R8810 Power Contactor

SKU: 1SBL161001R8810
Regular price $248.66
In stock (98 units)
Condition
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

ABB product — A12-30-10

-->

Product identification

  • Model: A12-30-10
  • Global material number: 1SBL161001R8810

Source: ABB official product data (dealer mirror: santaclarasystems.com)

Evidence URL: https://www.santaclarasystems.com/abb/1sbl161001r8810

Technical specifications

Source: ABB official product data (dealer mirror: santaclarasystems.com) — https://www.santaclarasystems.com/abb/1sbl161001r8810

Technical

Product ID 1SBL161001R8810
Extended Product Type 1SBL161001R8810
Product Net Weight 0.340 kg
Product Net Width 44 mm
Product Net Height 74 mm
Product Net Depth 74 mm
Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Ambient Air Temperature Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
Standards Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Impulse Withstand Voltage (Uimp) 8 kV
Rated Insulation Voltage (Ui) acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Terminal Type Screw Terminals
Rated Frequency (f) Supply Circuit 50 Hz Supply Circuit 60 Hz
Number of Auxiliary Contacts NO 1
Number of Auxiliary Contacts NC 0
Connecting Capacity Main Circuit Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
GOST Certificate GOST_POCCFRME77B07175
Maximum Operating Altitude Permissible 3000 m
Rated Control Circuit Voltage (Uc) 50 Hz 230 … 240 V 60 Hz 240 … 260 V
Climatic Withstand acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Mechanical Switching Frequency 3600 cycles per hour
Connecting Capacity Auxiliary Circuit Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
Operate Time Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Number of Main Contacts NO 3
GL Certificate DNV-GL_TAE00000TX
Number of Main Contacts NC 0
Short-Circuit Protective Devices Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A
Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Coil Consumption Average Holding Value 50 / 60 Hz 8 V·A Average Holding Value 50 / 60 Hz 2 W Average Pull-in Value 50 Hz 74 V·A Average Pull-in Value 60 Hz 70 V·A
Coil Operating Limits (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
Connecting terminals (delivered in open position) Main poles M 3.5 (+,-) pozidriv 2 screws with cable clamp
EAN 3471522042880
Rated Operational Voltage Main Circuit 690 V
Conventional Free-air Thermal Current (Ith) acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (Ie) (690 V) 40 °C 27 A (690 V) 55 °C 25 A (690 V) 70 °C 20 A
Rated Operational Current AC-3 (Ie) (220 / 230 / 240 V) 55 °C 12 A (380 / 400 V) 55 °C 12 A (415 V) 55 °C 12 A (440 V) 55 °C 12 A (500 V) 55 °C 12 A (690 V) 55 °C 9 A
Rated Operational Power AC-3 (Pe) (220 / 230 / 240 V) 3 kW (380 / 400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1 10 x Ie AC-3
Rated Operational Current AC-15 (Ie) (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
Maximum Electrical Switching Frequency AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
Rated Operational Current DC-13 (Ie) (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
Resistance to Shock acc. to IEC 60068-2-27 Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
Instructions and Manuals FPTC407721P0001
BV Certificate BV_2634H07559D0
CB Certificate CB_FR_602227A
CCC Certificate CCC_2013010304615753 CCC_2004010309130463
cUL Certificate UL_20160205-E312527-10-2
Data Sheet, Technical Information 1SBC100122C0202_Ch02
Declaration of Conformity - CE 1SBD250801U1000
DNV Certificate DNV-GL_TAE00000TX
EAC Certificate EAC_RU C-FR ME77 B01010
LOVAG Certificate LOVAG_FR97038
LR Certificate LRS_9830011E4
RINA Certificate RINA_ELE128713XG001
RMRS Certificate RMRS_0507015250
E-nummer 3227705
UNSPSC 39121529
Object Classification Code Q

Frequently asked questions

What is the rated supply voltage?

8 kV

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Impulse Withstand Voltage (Uimp)" (https://www.santaclarasystems.com/abb/1sbl161001r8810)

What is the rated current?

acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A acc. to IEC 60947-5-1, q = 40 °C 16 A

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Conventional Free-air Thermal Current (Ith)" (https://www.santaclarasystems.com/abb/1sbl161001r8810)

How many poles / contacts does it have?

1

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Number of Auxiliary Contacts NO" (https://www.santaclarasystems.com/abb/1sbl161001r8810)

What is the rated frequency?

Supply Circuit 50 Hz Supply Circuit 60 Hz

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Frequency (f)" (https://www.santaclarasystems.com/abb/1sbl161001r8810)

What is the degree of protection?

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Degree of Protection" (https://www.santaclarasystems.com/abb/1sbl161001r8810)

What is the power rating?

(220 / 230 / 240 V) 3 kW (380 / 400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW

Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Operational Power AC-3 (Pe)" (https://www.santaclarasystems.com/abb/1sbl161001r8810)

-->

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. Express shipping is a fixed USD 50.00 for eligible destinations in the United States and Canada.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date the order is placed (order date), against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★