ABB product — A12-30-10
-->
Product identification
- Model: A12-30-10
- Global material number: 1SBL161001R8110
Source: ABB official product data (dealer mirror: santaclarasystems.com)
Evidence URL: https://www.santaclarasystems.com/abb/1sbl161001r8110
Technical specifications
Source: ABB official product data (dealer mirror: santaclarasystems.com) — https://www.santaclarasystems.com/abb/1sbl161001r8110
Technical
| Product ID |
1SBL161001R8110 |
| Extended Product Type |
1SBL161001R8110 |
| Product Net Weight |
0.340 kg |
| Product Net Width |
44 mm |
| Product Net Height |
74 mm |
| Product Net Depth |
74 mm |
| Degree of Protection |
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| Ambient Air Temperature |
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C |
| Standards |
Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1 |
| Rated Impulse Withstand Voltage (Uimp) |
8 kV |
| Rated Insulation Voltage (Ui) |
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V |
| Terminal Type |
Screw Terminals |
| Rated Frequency (f) |
Supply Circuit 50 Hz Supply Circuit 60 Hz |
| Number of Auxiliary Contacts NO |
1 |
| Number of Auxiliary Contacts NC |
0 |
| Mechanical Durability |
10 million |
| Connecting Capacity Main Circuit |
Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm² |
| GOST Certificate |
GOST_POCCFRME77B07175 |
| Maximum Operating Altitude Permissible |
3000 m |
| Rated Control Circuit Voltage (Uc) |
50 Hz 24 V 60 Hz 24 V |
| Climatic Withstand |
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II |
| Maximum Mechanical Switching Frequency |
3600 cycles per hour |
| Connecting Capacity Auxiliary Circuit |
Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm² |
| Operate Time |
Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms |
| Country of Origin |
France (FR) |
| Number of Main Contacts NO |
3 |
| GL Certificate |
DNV-GL_TAE00000TX |
| Number of Main Contacts NC |
0 |
| Short-Circuit Protective Devices |
Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A |
| Maximum Breaking Capacity |
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Coil Consumption |
Average Holding Value 50 / 60 Hz 8 V·A Average Holding Value 50 / 60 Hz 2 W Average Pull-in Value 50 Hz 74 V·A Average Pull-in Value 60 Hz 70 V·A |
| Coil Operating Limits |
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C |
| Connecting terminals (delivered in open position) Main poles |
M 3.5 (+,-) pozidriv 2 screws with cable clamp |
| Lead Time |
16 day(s) |
| EAN |
3471522042811 |
| Criticality |
No |
| Made To Order |
No |
| Product Sales Status |
Active |
| Quote Only |
No |
| Rated Operational Voltage |
Main Circuit 690 V |
| Conventional Free-air Thermal Current (Ith) |
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A acc. to IEC 60947-5-1, q = 40 °C 16 A |
| Rated Operational Current AC-1 (Ie) |
(690 V) 40 °C 27 A (690 V) 55 °C 25 A (690 V) 70 °C 20 A |
| Rated Operational Current AC-3 (Ie) |
(220 / 230 / 240 V) 55 °C 12 A (380 / 400 V) 55 °C 12 A (415 V) 55 °C 12 A (440 V) 55 °C 12 A (500 V) 55 °C 12 A (690 V) 55 °C 9 A |
| Rated Operational Power AC-3 (Pe) |
(220 / 230 / 240 V) 3 kW (380 / 400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW |
| Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1 |
8 x Ie AC-3 |
| Rated Making Capacity AC-3 acc. to IEC 60947-4-1 |
10 x Ie AC-3 |
| Rated Operational Current AC-15 (Ie) |
(220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A |
| Maximum Electrical Switching Frequency |
AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour |
| Rated Operational Current DC-13 (Ie) |
(125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A |
| Resistance to Shock acc. to IEC 60068-2-27 |
Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g |
| Instructions and Manuals |
FPTC407721P0001 |
| BV Certificate |
BV_2634H07559D0 |
| CB Certificate |
CB_FR_602227A |
| CCC Certificate |
CCC_2013010304615753 CCC_2004010309130463 |
| cUL Certificate |
UL_20160205-E312527-10-2 |
| Data Sheet, Technical Information |
1SBC100122C0202_Ch02 |
| Declaration of Conformity - CE |
1SBD250801U1000 |
| DNV Certificate |
DNV-GL_TAE00000TX |
| EAC Certificate |
EAC_RU C-FR ME77 B01010 |
| LOVAG Certificate |
LOVAG_FR97038 |
| LR Certificate |
LRS_9830011E4 |
| RINA Certificate |
RINA_ELE128713XG001 |
| RMRS Certificate |
RMRS_0507015250 |
| E-nummer |
3227701 |
| UNSPSC |
39121529 |
| Object Classification Code |
Q |
Frequently asked questions
What is the rated supply voltage?
8 kV
Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Impulse Withstand Voltage (Uimp)" (https://www.santaclarasystems.com/abb/1sbl161001r8110)
What is the rated current?
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A acc. to IEC 60947-5-1, q = 40 °C 16 A
Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Conventional Free-air Thermal Current (Ith)" (https://www.santaclarasystems.com/abb/1sbl161001r8110)
How many poles / contacts does it have?
1
Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Number of Auxiliary Contacts NO" (https://www.santaclarasystems.com/abb/1sbl161001r8110)
What is the rated frequency?
Supply Circuit 50 Hz Supply Circuit 60 Hz
Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Frequency (f)" (https://www.santaclarasystems.com/abb/1sbl161001r8110)
What is the degree of protection?
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Degree of Protection" (https://www.santaclarasystems.com/abb/1sbl161001r8110)
What is the power rating?
(220 / 230 / 240 V) 3 kW (380 / 400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
Source: ABB official product data (dealer mirror: santaclarasystems.com), field "Rated Operational Power AC-3 (Pe)" (https://www.santaclarasystems.com/abb/1sbl161001r8110)
-->