Phoenix Contact · Signal conditioner
2902063 – MINI MCR-2-UI-I-OLP-PT · Signal conditioner
The Phoenix Contact 2902063 (MINI MCR-2-UI-I-OLP-PT) is a Signal conditioner in the Phoenix Contact range. The specification below is transcribed from the official Phoenix Contact product page for this order number, which publishes the technical data in 15 sections: Notes, Product properties, Electrical properties, Input data, Output data, Connection data and further sections.
Rated current50 mA (Dielectric strength up to 30 V)
Degree of protectionIP20 (not assessed by UL)
Ambient temperature-40 °C ... 70 °C
Dimensions6.2 mm
ConnectionPush-in connection
MaterialPBT
How it works
Phoenix Contact keeps the values in the groups shown below, in the order the manufacturer publishes them: Notes, Product properties, Electrical properties, Input data, Output data, Connection data, Ex data, Signaling, Dimensions, Material specifications, Environmental and real-life conditions, Approvals, EMC data, Standards and regulations, Mounting. The values are carried over unchanged from the official product page; nothing is added beyond what the manufacturer states for this order number.
Specifications
Notes
Note on application
Note on applicationAs things stand now, we are preparing the product so that, as of December 11, 2027, it will comply with the requirements of the EU Cyber Resilience Act (CRA) based on the information currently available regarding the CRA.
Utilization restriction
EMC noteEMC: class A product, see manufacturer's declaration in the download area
Product properties
Product typeSignal conditioner
Product familyMINI Analog Pro
No. of channels1
ConfigurationDIP switches
Electrical properties
Electrical isolation2-way isolation
Electrical isolation between input and outputyes
Limit frequency (3 dB)approx. 30 Hz
Step response (10-90%)20 ms
Maximum temperature coefficient0.01 %/K
Temperature coefficient, typical0.005 %/K
Maximum transmission error≤ 0.1 % (of final value)
Electrical isolation
Overvoltage categoryII
Pollution degree2
Electrical isolation Input/output/power supply IEC/EN 61010-1
Standards/regulationsIEC/EN 61010-1
Rated insulation voltage300 V rms
Test voltage3 kV AC (50 Hz, 60 s)
InsulationReinforced insulation
Supply
Supply voltage range8 V DC ... 30 V DC (loop-powered, no external supply necessary)
Typical current consumption≤ 20 mA
Power consumption≤ 600 mW
Input data
Signal: Voltage/current
Number of inputs1
Configurable/programmableYes
Voltage input signal0 mV ... 1000 mV
Value0 mV ... 750 mV
Value0 mV ... 500 mV
Value0 mV ... 300 mV
Value0 mV ... 250 mV
Value0 mV ... 200 mV
Value0 mV ... 125 mV
Value0 mV ... 120 mV
Value0 mV ... 150 mV
Value0 mV ... 100 mV
Value0 mV ... 75 mV
Value0 mV ... 60 mV
Value0 mV ... 50 mV
Value0 V ... 10 V
Value0 V ... 7.5 V
Value0 V ... 5 V
Value0 V ... 3 V
Value0 V ... 2.5 V
Value0 V ... 2 V
Value0 V ... 1.5 V
Value0 V ... 1.25 V
Value0 V ... 1.2 V
Value0 V ... 30 V
Value0 V ... 25 V
Value0 V ... 20 V
Value0 V ... 12.5 V
Value0 V ... 12 V
Value0 V ... 15 V
Value-1000 mV ... 1000 mV
Value-750 mV ... 750 mV
Value-500 mV ... 500 mV
Value-300 mV ... 300 mV
Value-250 mV ... 250 mV
Value-200 mV ... 200 mV
Value-125 mV ... 125 mV
Value-120 mV ... 120 mV
Value-150 mV ... 150 mV
Value-100 mV ... 100 mV
Value-75 mV ... 75 mV
Value-60 mV ... 60 mV
Value-50 mV ... 50 mV
Value-10 V ... 10 V
Value-7.5 V ... 7.5 V
Value-5 V ... 5 V
Value-3 V ... 3 V
Value-2.5 V ... 2.5 V
Value-2 V ... 2 V
Value-1.25 V ... 1.25 V
Value-1.2 V ... 1.2 V
Value-1.5 V ... 1.5 V
Value-30 V ... 30 V
Value-25 V ... 25 V
Value-20 V ... 20 V
Value-12.5 V ... 12.5 V
Value-12 V ... 12 V
Value-15 V ... 15 V
Value2 V ... 10 V (additional areas can be configured, see table)
Value1 V ... 5 V (additional areas can be configured, see table)
Max. voltage input signal< 30 V
Current input signal0 mA ... 40 mA
Value0 mA ... 30 mA
Value0 mA ... 20 mA
Value0 mA ... 12 mA
Value0 mA ... 10 mA
Value0 mA ... 8 mA
Value0 mA ... 7.5 mA
Value0 mA ... 6 mA
Value0 mA ... 5 mA
Value0 mA ... 4 mA
Value0 mA ... 3 mA
Value0 mA ... 2.5 mA
Value0 mA ... 2 mA
Value4 mA ... 20 mA
Value2 mA ... 10 mA
Value1 mA ... 5 mA
Max. current input signal50 mA (Dielectric strength up to 30 V)
Input resistance of voltage input 100 kΩ (≤ 1 V)
Value 1 MΩ (≥ 1 V)
Input resistance current input25 Ω (+0.7 V for test diode)
Output data
Signal: Current
Number of outputs1
Current output signal4 mA ... 20 mA
Max. current output signal32 mA
Load/output load current output< 1000 Ω ((U B - 8 V) / 22 mA)
Ripple< 10 mV rms (at 600 Ω)
Connection data
Connection methodPush-in connection
Stripping length10 mm
Conductor cross-section rigid0.2 mm² ... 2.5 mm² (with ferrule)
Value0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross-section flexible0.14 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12 (flexible)
Ex data
Ex installation (EPL)Gc
ValueDiv. 2
Signaling
Status displayGreen LED (supply voltage)
Dimensions
Width6.2 mm
Height109.81 mm
Depth119.2 mm
Material specifications
Colorgray (RAL 7042)
Housing materialPBT
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2
Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20 (not assessed by UL)
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Approvals
CE
CertificateCE-compliant
ATEX
Identification II 3 G Ex ec IIC T4 Gc
CertificateBVS 19 ATEX E 079 X
IECEx
IdentificationEx ec IIC T4 Gc
CertificateIECEx BVS 19.0068X
CCC / China-Ex
IdentificationEx ec IIC T4 Gc
UL, USA/Canada
IdentificationUL 508 Listed
ValueClass I, Div. 2, Groups A, B, C, D T5
ValueClass I, Zone 2, Group IIC T5
Shipbuilding approval
CertificateDNV GL TAA000021E Rev. 1
EAC Ex
Identification 2Ex ec IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00081
Shipbuilding data
TemperatureB
HumidityB
VibrationA
EMCA
EnclosureRequired protection according to the Rules shall be provided upon installation on board
EMC data
Electromagnetic compatibilityConformance with EMC directive
Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Noise emission
Standards/regulationsEN 61000-6-4
Standards and regulations
Electrical isolation2-way isolation
GB Standard
Standards/regulationsGB/T 3836.1
ValueGB/T 3836.3
Mounting
Mounting typeDIN rail mounting
Mounting positionany
Order number
2902063 — https://www.phoenixcontact.com/en-us/products/signal-conditioner-mini-mcr-2-ui-i-olp-pt-2902063
Official source
Phoenix Contact official product page, technical data section (EN-US); order number 2902063.
FAQ
What degree of protection does the 2902063 have?
It is rated IP20 (not assessed by UL), as stated in the official technical data.
What ambient temperature is permitted?
Phoenix Contact specifies an ambient temperature of -40 °C ... 70 °C.
What are the dimensions?
The technical data gives 6.2 mm.
How is the 2902063 connected?
Phoenix Contact specifies the connection as Push-in connection.
What material is the housing made of?
The technical data lists PBT.
Shipping & support. Stock is held in Shanghai and dispatched worldwide with the manufacturer's documentation. Contact us for the current lead time, price and freight before ordering.