Phoenix Contact · I/O component
2701496 – AXL E EIP IOL8 DI4 M12 6P · I/O component
The Phoenix Contact 2701496 (AXL E EIP IOL8 DI4 M12 6P) is an I/O component in the Phoenix Contact range. The specification below is transcribed from the official Phoenix Contact product page for this order number, which publishes the technical data in 12 sections: Dimensions, Notes, Mounting, Material specifications, Interfaces, Input data and further sections.
Nominal voltage24 V DC
Degree of protectionIP65/IP67
Ambient temperature-25 °C ... 60 °C
Dimensions60 mm
ConnectionM12 connector
MaterialPocan®
How it works
Phoenix Contact keeps the values in the groups shown below, in the order the manufacturer publishes them: Dimensions, Notes, Mounting, Material specifications, Interfaces, Input data, Output data, Product properties, Electrical properties, Connection data, Environmental and real-life conditions, Standards and regulations. The values are carried over unchanged from the official product page; nothing is added beyond what the manufacturer states for this order number.
Specifications
Dimensions
Width60 mm
Height185 mm
Depth30.5 mm
Drill hole spacing198.5 mm
Note on dimensionsThe height is 212 mm including fixing clips.
Notes
Note on application
Note on applicationOnly for industrial use
Mounting
Mounting typeScrew mounting
Material specifications
Color (Housing)anthracite gray (RAL 7016)
Housing materialPocan®
Interfaces
EtherNet/IP™
Number of interfaces2
Connection methodM12 connector
Note on the connection methodD-coded
Number of positions4
Transmission speed10/100 Mbps (with auto negotiation)
EtherNet/IP™
Equipment typeEtherNet/IP™ device
System-specific protocolsEtherNet/IP™ protocols ACD
ValueEtherNet/IP™ protocols DLR
ValueEtherNet/IP™ protocols IGMP v2
Protocols supportedSNMP v1
ValueHTTP
ValueTFTP
ValueFTP
ValueBootP
ValueDHCP
SpecificationCIP Edition 3.11 EIP adaptation of CIP 1.12
Input data
Digital:
Input nameDigital inputs at pin 2 for class A ports
Description of the inputIEC 61131-2 type 1
Number of inputs4
Connection methodM12 connector, X01 ... X04 have double occupancy
Connection technology3-conductor
Input voltage range "0" signal-0.3 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input voltage U IN24 V DC
Nominal input current at U INtyp. 3 mA
Sensor current per channelmax. 200 mA (from L+/L-)
Total sensor currentmax. 1.6 A (from L+/L-)
Input frequency0.5 kHz
Input filter time< 1000 µs
Protective circuitOverload protection, short-circuit protection of sensor supply
Digital
Description of the inputIO-Link ports in digital input (DI) mode
Number of inputsmax. 8 (IEC 61131-2 type 1)
Connection methodM12 connector, X01 ... X04 have double occupancy
Connection technology3-conductor
Nominal input voltage U IN24 V DC
Input voltage range "0" signal-0.3 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input currenttyp. 3 mA
Sensor current per channelmax. 200 mA (from L+/L-)
Total sensor currentmax. 1.6 A (from L+/L-)
Input filter time< 1000 µs
Input frequency0.5 kHz
Protective circuitOverload protection; yes
ValueShort-circuit protection for the sensor supply; yes
IO-Link
Number of ports4
Connection methodM12 connector
Connection technology3-conductor
Port typeClass A
Cycle Timemin. 2 ms (MasterCycleTime: PDInput* + PDOutput* + OnReqData* < = 17 Bytes, COM3; * see "IO-Link Interface and System Specification V1.1.2")
IO-Link
Number of ports4
Connection methodM12 connector
Connection technology3-conductor
Port typeClass B
Cycle Timemin. 2 ms (MasterCycleTime: PDInput* + PDOutput* + OnReqData* < = 17 Bytes, COM3; * see "IO-Link Interface and System Specification V1.1.2")
Output data
Digital
Output descriptionIO-Link ports in digital output (DO) mode
Connection methodM12 connector, X01 ... X04 have double occupancy
Connection technology3-conductor
Number of outputsmax. 8
Nominal output voltage24 V DC
Maximum output current per channel150 mA
Maximum output current per module1.2 A
Nominal load, ohmic3.6 W (160 Ω, at nominal load)
Nominal load, inductive3.6 VA (0.8 H, 160 Ω, at nominal load)
Signal delaymax. 150 µs (when switched on)
Valuemax. 200 µs (when switched off)
Switching rate1 per second, maximum (at nominal inductive load)
Value5500 per second, maximum (at nominal ohmic load)
Limitation of the voltage induced on circuit interruption-15 V DC
Output voltage when switched offmax. 1 V
Output current when switched offmax. 300 µA
Protective circuitOverload protection; yes
ValueShort-circuit protection; yes
Behavior with overloadShutdown with automatic restart
Product properties
Product typeI/O component
Product familyAxioline E
TypeStand-alone
Special propertiesPlastic housing
Electrical properties
Potentials
Voltage supply U S24 V DC
Power supply at U Smax. 4 A
Current consumption from U Styp. 8 mA
Valuemax. 1.2 A
Supply: IO-Link
Nominal voltage for I/O supply24 V DC
Nominal current for every IO-Link portmax. 150 mA (at C/Q (pin 4), maximum of 1.6 A over all 8 IO-Link C/Q and L+ cables)
Valuemax. 200 mA (at L+/L- (pin 1 and pin 3), during startup, up to 1.6 A for short periods)
Valuemax. 2 A (at U A (IO-Link B ports, pin 2 and pin 5))
Permissible cable length< 20 m (to the sensor)
Protective circuitOverload protection; yes
Supply: Module electronics and sensors
DesignationSupply of module electronics and sensors (U S )
Connection methodM12 connector, T-coded
Number of positions4
Supply voltage24 V DC
Supply voltage range19.5 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptiontyp. 180 mA ±15 % (at 24 V DC)
Valuemax. 12 A
Supply: Actuators
DesignationSupply of actuators (U A )
Connection methodM12 connector, T-coded
Number of positions4
Supply voltage24 V DC
Supply voltage range18 V DC ... 31.2 V DC (including all tolerances, including ripple)
Current consumptiontyp. 28 mA ±15 % (at 24 V DC)
Valuemax. 12 A
Electrical isolation/isolation of the voltage ranges
Test voltage: 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1)500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (communications power and sensor supply, IO-Link ports)/FE500 V AC, 50 Hz, 1 min
Test voltage: Bus connection (Ethernet 1)/FE500 V AC, 50 Hz, 1 min
Test voltage: Bus connection (Ethernet 2)/FE500 V AC, 50 Hz, 1 min
Test voltage: Bus connection (Ethernet 1)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, IO-Link ports)500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 1)500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (actuator supply)/bus connection (Ethernet 2)500 V AC, 50 Hz, 1 min
Test voltage: 24 V supply (actuator supply)/FE500 V AC, 50 Hz, 1 min
Connection data
Connection methodM12 connector
Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 60 °C
Degree of protectionIP65/IP67
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (storage/transport)5 % ... 95 %
Mechanical test
Vibration resistance in accordance with EN 60068-2-6/IEC 60068-2-65g
Shock in accordance with EN 60068-2-27/IEC 60068-2-2730g, 11 ms period, half-sine shock pulse
Continuous shock in accordance with EN 60068-2-27/IEC 60068-2-2710g
Standards and regulations
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)
Order number
2701496 — https://www.phoenixcontact.com/en-us/products/io-component-axl-e-eip-iol8-di4-m12-6p-2701496
Official source
Phoenix Contact official product page, technical data section (EN-US); order number 2701496.
FAQ
What voltage does the 2701496 operate at?
Phoenix Contact gives a nominal voltage of 24 V DC for this order number.
What degree of protection does the 2701496 have?
It is rated IP65/IP67, as stated in the official technical data.
What ambient temperature is permitted?
Phoenix Contact specifies an ambient temperature of -25 °C ... 60 °C.
What are the dimensions?
The technical data gives 60 mm.
How is the 2701496 connected?
Phoenix Contact specifies the connection as M12 connector.
What material is the housing made of?
The technical data lists Pocan®.
Shipping & support. Stock is held in Shanghai and dispatched worldwide with the manufacturer's documentation. Contact us for the current lead time, price and freight before ordering.