Keyence LK-G37
Sensor Head: High Accuracy, Wide beam LK-G37
Specifications
| Model |
| LK-G37; Reference distance |
| Diffused reflection |
30 mm 1.18" , Specular reflection: 23.5 mm 0.93"; Measuring range |
| Diffused reflection |
±5 mm ±0.2" , Specular reflection: ±4.5 mm ±0.18" *1 *2; Light source |
| Type |
| Red semiconductor laser; Wavelength |
| 655 nm (visible light); Laser Class |
| Class II (FDA CDRH 21CFR PART1040.10); Output |
| 0.95 mW; Spot diameter (at reference distance) |
| Approx. 30 x 850 µm 0.0012" x 0.0335"; Linearity |
| ±0.05 % of F.S. (F.S.= ±5 mm ±0.2" ) *3; Repeatability |
| 0.05 µm *4; Sampling frequency |
| 20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels); LED display |
| Near the center of the measurement |
Green lights Within the measurement area: Orange lights Outside the measurement area: Orange flashing; Temperature characteristics |
| 0.01 % of F.S./°C (F.S.= ±5 mm ±0.2" ); Environmental resistance |
| Enclosure rating |
| IP67 (IEC60529); Ambient light |
| Incandescent lamp or Fluorescent lamp |
10,000 lux max.; Ambient temperature |
| 0 to +50 °C 32 to 122 °F; Relative humidity |
| 35 to 85 % RH (No condensation); Vibration resistance |
| 10 to 55 Hz, Double amplitude 1.5 mm 0.06" , 2 hours in each of the X, Y, and Z directions; Material |
| Aluminum die-cast; Weight |
| Approx. 280 g (including the cable); *1 The range is obtained by measuring KEYENCE's standard target (ceramic). *2 When the sampling rate is 20 µs, the range becomes +1.8 mm +0.07" (FAR side) to -5 mm -0.20" (NEAR side) for Diffused reflection, and +1.6 mm +0.06" (FAR side) to -4.5 mm -0.18" (NEAR side) *3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode. *4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance. |
Description
LK-G37, Sensor Head: High Accuracy, Wide beam in LK-G3000 series by KEYENCE America.