ABB

ABB ACS880-01-061A-3

SKU: ACS880-01-061A-3
Regular price $1,688.88
In stock
Usually ships within 72 hours
Condition
Factory pre-tested, ready for instant commissioning!

All industrial automation equipment comes complete with standard matching accessories and detailed step-by-step commissioning manuals. Unbox, install and commission your automation projects smoothly with full confidence.

Free shipping
100% secure payments
Industry leading quality
Motion  |  Low-voltage AC drives  |  ACS880 industrial single drives

ACS880-01-061A-3

Wall-mounted industrial drive · official technical specifications · 30 kW / 61 A, 400 V class, Frame size R4

Product ID: 3AUA0000108021 Supply: 3-phase 380–415 V AC Nominal output: 61 A / 30 kW Frame: R4 · IP21 (UL Type 1) Control: DTC · STO SIL 3 / PL e

Key Ratings at a Glance (UN = 400 V, ambient 40 °C)

Nominal I2 / IN (no overload)
61 A · 30 kW
Light overload ILd (110%, 1 min/5 min)
58 A · 30 kW
Heavy duty IHd (150%, 1 min/5 min)
45 A · 22 kW
Maximum Imax (start, 10 s)
76 A
Input voltage U1
380–415 V AC, 3~ (+10/−15%)
Input current I1
≈ 58 A rms
Heat loss / airflow
907 W · 200 m³/h
Noise / weight IP21
62 dBA · 18.5 kg

Output Current Profile by Duty Mode

Nominal I2 (continuous)
61 A — no overload, 30 kW
61 A
Light overload ILd
58 A cont. + 110% for 1 min / 5 min
58 A
Heavy duty IHd
45 A cont. + 150% for 1 min / 5 min
45 A
Maximum Imax
76 A — up to 10 s at start
76 A
Continuous-duty current (40 °C)Peak output current Imax
Apparent power SN ≈ 42 kVA. Ratings valid at 40 °C ambient; 40–55 °C derate 1% per 1 °C. Light overload allows 110% × ILd for 1 minute every 5 minutes; heavy-duty use allows 150% × IHd for 1 minute every 5 minutes.

Type Designation Breakdown

ACS880 - 01 - 061A - 3 [ + options ]

ACS880All-compatible industrial drive series (common architecture / primary control program)
01Construction: wall-mounted single drive (book-style, IP21 standard)
061ANominal output current: 61 A
3Voltage class UN3: 380–415 V AC (typical 3~400 V)
Common factory options +E200/+E202 internal EMC filter · +D150 internal brake chopper (option for R5–R9; standard on R1–R4) · +D151 brake resistor · +P940/+P944 flange mounting (IP20 back side) · +Fxxx fieldbus/feedback adapters · +FSO safety functions module · control panel ACS-AP-I / ACS-AP-W (Bluetooth)

Power Stage — Input (Supply)

Mains supply (U1)
Phases 3-phase (3~)
Input voltage 380–415 V AC, tolerance +10% / −15% (label: 3~400 V)
Input frequency 50/60 Hz ±5%, max. rate of change 17%/s
Nominal input current I1 ≈ 58 A rms at nominal load
Fundamental power factor cos φ1 = 0.98
Network types Grounded TN and ungrounded IT systems
Built-in components AC (mains) choke/reactor built in as standard; internal EMC filter by option
Protection & wiring
Short-circuit withstand 65 kA prospective (IEC, with specified fuses); 100 kA rms at ≤600 V (UL/NEC, with UL fuses)
IEC fuses IEC 60269 gG or ultra-rapid aR, 500 V, sized per the Hardware Manual fuse table (100 A class for R4/061A; never exceed ABB's recommended rating; smaller allowed)
UL fuses UL Class T recommended; Class J / CC / CF of same rating also accepted (NEC branch-circuit protection)
IEC breaker example ABB S803S-SCL32-SR / MS165-65 motor-protector combination per Hardware Manual breaker table
Power cable (typical) Symmetrical shielded VFD cable, copper; R4 400 V class typically 3×16 mm² Cu (select per installation conditions, 75 °C min.)

Output, Motor Control & Thermal Data

Output (U/V/W) 3-phase symmetrical, 0 … U1
Output frequency 0–598 Hz standard; 0–120 Hz with du/dt or sine filter; “High speed mode” recommended at ≥120 Hz
Motor control ABB Direct Torque Control (DTC) as standard; scalar control available; default switching frequency 2 kHz, selectable (low-noise mode) with current derating
Motor types Asynchronous AC induction motors, permanent-magnet synchronous motors, AC induction servomotors, ABB synchronous reluctance motors (SynRM)
Max. motor cable 300 m (984 ft) for frames R4–R9; EMC directive compliance guaranteed to 150 m (492 ft)
Power loss (heat dissipation) 907 W at nominal load
Cooling / noise Forced-air cooling, controllable fan, required air flow 200 m³/h; sound pressure 62 dBA; incoming-air temperature sensing; free space 200 mm above/below (IP21), 300 mm for IP55

Built-in braking chopper & resistor selection (standard on R4)

Continuous chopper power Pbrcont 22 kW (applies at minimum resistance)
Minimum resistor resistance Rmin 13 Ω — never connect a lower resistance
ABB standard resistor SACE15RE13: R = 13 Ω, single-pulse energy Er = 435 kJ (400 s duty cycle), continuous dissipation Prcont = 2 kW; IP21 metal housing, 365 × 290 × 131 mm, 6.8 kg; built-in thermal switch must be wired to a drive DI

Control Unit I/O (ZCU control board, removable)

Digital inputs 6 × DI (DI1–DI5 NPN/PNP, DI6 PNP), 24 V logic (“0” < 5 V, “1” > 15 V), Rin 2.0 kΩ, hardware filter 0.04 ms + digital filter up to 8 ms; separate start-interlock input DIIL
Digital I/O 2 × DIO (input/output by parameter); DIO1 configurable as 0–16 kHz frequency input, DIO2 as frequency output
Analog inputs 2 × differential AI, jumper-selectable current −20…20 mA (Rin 100 Ω) or voltage −10…10 V (Rin > 200 kΩ); 11-bit + sign, 0.25 ms sampling, inaccuracy 1%
Analog outputs 2 × AO, 0–20 mA, Rload < 500 Ω, 0–300 Hz, 11-bit + sign, inaccuracy 2%
Relay outputs 3 × RO (RO1, RO2 normally open; RO3 changeover), configurable
Auxiliary / references +24 V DC output (total 4.8 W / 200 mA); ±10 V reference outputs (10 mA max)
Built-in links Drive-to-drive XD2D, RS-485, 8 Mbit/s, max 50 m · embedded fieldbus EFB RS-485 (Modbus RTU), max 50 m · control-panel port with USB · removable memory unit for commissioning/maintenance swap

Communication, Options & Expandability

Fieldbus option slots Optional adapters: PROFINET IO / EtherNet/IP / Modbus TCP / EtherCAT (FENA/FECA/FPNO families), PROFIBUS DP (FPBA), CANopen (FCAN), DeviceNet, EtherNet POWERLINK and more; drive profile CiA402 / PROFIdrive compatible
Feedback interfaces FEN-xx incremental/absolute encoder modules, FSE pulse-encoder interface; resolver via adapter; supports closed-loop DTC speed/torque/position control
Functional safety options FSO-12 / FSO-22 safety functions module (TÜV Nord certified): SS1, SS2, SLS, SMS, SBC, SLP/SP etc.; FPTC thermistor module; optional safe pulse encoder
Motor-side filters du/dt filter option (FOCH) and sine filter option for motor insulation / long-cable protection; external/second-environment EMC filters available
Software ACS880 primary control program (common across the series); optional application programs (crane +N5050, position control +N5700, winder, solar etc.); Drive Composer PC tool; ACS-AP assistant control panel (AP-W with Bluetooth)

Functional Safety — Safe Torque Off (STO), standard

Architecture Two-channel STO on XSTO connector (input −3…30 V DC, “1” > 17 V, 30 mA per channel on R1–R7); can be daisy-chained between drives; main I/O stays powered during STO
Standards / levels IEC/EN 61800-5-2 STO · IEC 61508 SIL 3 · EN 62061 SIL CL 3 · EN ISO 13849-1 PL e, Category 3, HFT 1; EMC immunity per IEC 61326-3-1 / IEC 61800-5-2
Quantitative data (R4, 400 V) SFF > 90% · DC ≥ 90% · CCF 80 · MTTFD 10,442 years · PFH 2.89×10⁻⁹ 1/h · mission time TM 20 years
Response times (ZCU) STO reaction time 1 ms; response 2 ms typical / 10 ms max; channel mismatch fault detection 200 ms

Mechanical Data — Frame R4

Height H1 (with cable entry box, IP21) 573 mm
Height H2 (without cable box) 490 mm
Width W 203 mm
Depth D (IP21, with box) 274 mm (333 mm IP20 variant)
Weight 18.5 kg IP21 (16.1 kg IP20); packaged ≈ 18.6 kg, net 580 × 203 × 274 mm
Degree of protection IP21 / UL Type 1 standard; IP55 / UL Type 12 option; +P940/+P944 flange mount with IP20/UL Open Type rear
Board protection Conformal-coated circuit boards as standard; corrosion-protection variant +P968 available
Mounting Vertical wall mounting; book-style side-by-side; removable control unit; class I protective, overvoltage category III (IEC 60664-1)

Environmental Conditions

Operating air temperature −15 … +55 °C (+5 … +131 °F), no frost; full ratings to +40 °C; derate 1% / 1 °C from +40 to +55 °C
Storage / transport (packaged) −40 … +70 °C (−40 … +158 °F)
Relative humidity 5–95%, non-condensing (max. 60% in presence of corrosive gases)
Altitude 0–4000 m (13,123 ft); rated to 1000 m, then derate 1 percentage point per 100 m (lower ambient offsets derating)
Vibration / shock EN 60068-2-6: max. 1 mm (5–13.2 Hz) / 7 m·s⁻² operation; ISTA 1A transport vibration (R1–R5)
Contamination Indoor controlled environment, pollution degree 2 (IEC 60664-1); no electrically conductive dust; chemical gases IEC Class C3 / ISA G2 for IP21

Compliance, Approvals & EMC

Approvals / marks CE, UKCA, cULus (UL & CSA, valid to 600 V), EAC, RCM; ACS880-01 available with marine type approvals from major classification societies
EMC EN/IEC 61800-3 Category C3 as standard; Category C2 (1st environment) achievable with internal EMC filter option (+E200/+E202)
Key standards EN/IEC 61800-5-1 (safety requirements), EN/IEC 61800-3 (EMC), EN/IEC 61800-5-2 (STO), IEC 61508, EN 62061, EN ISO 13849-1, IEC/EN 60529 (IP), UL 61800-5-1 / CSA C22.2 No.274-17, NEC
Integrated protections Output short-circuit, mains loss/undervoltage/overvoltage, earth fault, motor & drive overtemperature, motor overload (per NEC/IEC 61800-5-1), STO diagnostics, brake chopper/resistor fault supervision
Technical reference · ABB ACS880-01-061A-3 · 30 kW, 61 A, 400 V, Frame R4 · Product ID 3AUA0000108021

Frequently Asked Questions

Q: What is the warranty for ABB ACS880-01-061A-3?

A: This vfd drive comes with manufacturer warranty. Contact us for specific warranty terms.

Q: How fast can you ship ACS880-01-061A-3?

A: Orders placed before 14:00 ship same day. Standard delivery: 5-8 business days worldwide. Express available.

Q: Is ACS880-01-061A-3 compatible with ABB systems?

A: Yes, ACS880-01-061A-3 is designed for full compatibility with ABB ecosystem. Contact our technical team for integration support.

Place your order before 14:00 for earliest possible shipment handover. With round-the-clock transit operated by our partnered global logistics providers, parcels reach most international destinations following routine customs processing. Economy shipping takes 5–8 business days, while express delivery arrives in 5–8 business days, both subject to customs clearance progress.Shipping fees will be charged for all orders under USD 500, and the exact shipping cost will be determined and collected by our logistics carriers. Shipments to remote international regions will incur additional courier surcharges to offset extra cross-border transportation costs.

Factory warranty service is not applicable to this industrial control equipment, and extended warranty packages are not provided for this item.

★★★★★

No reviews yet. Be the first to review this product!