Motion  |  Low-voltage AC drives  |  ACS380 machinery drives

ACS380-040N-09A4-4

Compact machinery drive · official technical specifications · 4 kW / 9.4 A, 3-phase 380–480 V, Frame size R1 · Base variant (N)

Nominal output: 9.4 A / 4.0 kW Supply: 3-phase 380–480 V AC Frame: R1 · IP20 (UL open) Variant: N — Base (2 DI + 1 RO + STO) EMC: internal C3 filter STO: SIL 3 / PL e

Variant Identification — what “040N” means

ACS380-040N-09A4-4 is the Base variant (“N”). It ships without an I/O or fieldbus extension module: the drive body itself provides only 2 digital inputs (DI1–DI2), 1 changeover relay output (RO1), dual-channel STO and the +24 V auxiliary output. There are no analog inputs/outputs and no Modbus on the N unit — these are added by plug-in option modules (BMIO-01 = the “S” standard I/O & Modbus set; BIO-01 I/O extension; BREL-01 relays; fieldbus adapters). See the Control I/O section for the full comparison.

Key Ratings at a Glance (IEC, 50 °C ambient, 4 kHz default)

Nominal IN (no overload)
9.4 A · 4.0 kW
Light overload ILd (110%, 1 min/10 min)
8.9 A · 4.0 kW
Heavy duty IHd (150%, 1 min/10 min)
7.2 A · 3.0 kW
Maximum Imax (2 s at start)
13.0 A
Input current I1
12.9 A rms
UL rating @480 V
5 Hp · 7.6 A (light duty)
Power loss / airflow
140 W · 57 m³/h (33 CFM)
Noise / weight
63 dBA · ≈1.6 kg

Output Current Profile by Duty Mode

Nominal IN (continuous)
9.4 A — no overload, 4.0 kW
9.4 A
Light overload ILd
8.9 A cont. + 110% for 1 min / 10 min
8.9 A
Heavy duty IHd
7.2 A cont. + 150% for 1 min / 10 min
7.2 A
Maximum Imax
13.0 A — 2 s at start (f < 9 Hz), every 10 min
13.0 A
Continuous-duty current (50 °C)Peak output current Imax
Apparent power SN ≈ 6.5 kVA at 400 V. Ratings valid to 50 °C ambient with the default 4 kHz switching frequency; 50–60 °C derate 1% per 1 °C. Switching-frequency derating for this frame: 4 kHz = 1.00 · 8 kHz = 0.65 · 12 kHz = 0.48.

Type Designation Breakdown

ACS380 - 04 - 0 - N - 09A4 - 4 [ + option codes ]

ACS380ABB machinery drive series (0.25–22 kW, 200–480 V)
04Construction: IP20 cabinet module, bottom cable entry, coated boards, STO + brake chopper built in
0EMC: low filtering, EN 61800-3 category C3 (400 V drives carry an internal C3 filter)
NConnectivity: Base variant — no I/O or fieldbus module fitted
09A4Nominal output current: 9.4 A
4Voltage: 3-phase 380–480 V AC
Variant letters at a glance S = Standard, BMIO-01 I/O & Modbus module fitted (fixed configuration)  ·  C = Configured, I/O or fieldbus module chosen by plus-code  ·  N = Base, module slot empty (this unit). High-filtering C2 build replaces the EMC digit “0” with “2” (ACS380-042x).

Power Stage — Input (Supply) & Protection

Mains supply (U1)
Phases 3-phase (3~)
Input voltage 380–480 V AC, tolerance −15% / +10%
Input frequency 47–63 Hz, max. rate of change 2%/s
Nominal input current I1 12.9 A rms at nominal load
Fundamental power factor cos φ = 0.98 (at nominal load)
Short-circuit rating Suitable on circuits delivering up to 100 kA rms at 480 V max. when protected by the specified UL fuses (10 kA without)
Protection devices (one per phase)
IEC gG fuse 16 A / 500 V — ABB Control OFAF000H16 (I²t 740, min. network short-circuit current 128 A)
IEC aR ultra-rapid fuse 40 A / 690 V — Bussmann 170M2696 (I²t 490)
UL fuse UL Class T, 20 A (NEC branch-circuit protection)
Manual motor protector ABB MS165-16 (set 12.2 A), Type E self-protected to 65 kA
Typical power cable Symmetrical shielded 3×2.5 mm² Cu + 2.5 mm² PE (AWG 14); select per installation conditions

Output, Motor Control & Thermal Data

Output (U/V/W) 3-phase symmetrical, 0 … U1; output is short-circuit proof per IEC/UL 61800-5-1
Output frequency 0–599 Hz, resolution 0.01 Hz
Switching frequency 2 / 4 / 8 / 12 kHz selectable; 4 kHz default (derating factors 1.00 / 1.00 / 0.65 / 0.48)
Motor control Sensorless vector and scalar control; adaptive programming built in; integrated mechanical-brake control state machine
Motor types Asynchronous AC induction motors, permanent-magnet synchronous motors, ABB synchronous reluctance motors (SynRM)
Typical power loss 140 W (478 BTU/h) at 90% motor frequency / 100% drive nominal current
Cooling / noise Fan cooling, bottom-to-top airflow 57 m³/h (33 CFM); sound pressure 63 dBA; keep 75 mm free space above/below (50 mm above the optional UL Type 1 hood)

Built-in braking chopper & resistor selection (standard on every ACS380)

Continuous braking capacity PBRcont 3.0 kW
Maximum braking capacity PBRmax 4.5 kW (PBRcont × 1.5; braking pulse ≤ 1 min per 10 min)
Allowed resistor range Rmin 53 Ω — Rmax 102 Ω (never connect below Rmin); max. resistor cable length 10 m (33 ft), shielded
Thermal protection Resistor thermal switch wired to a drive DI; chopper enable/thermal model in parameter group 43

Control I/O — Base variant “N” (this drive) vs. extension modules

On-board terminals of the ACS380-040N base unit

Digital inputs 2 × DI (DI1, DI2), 12–24 V DC (max. 30 V), Rin 2.0 kΩ, PNP/NPN, internal or external supply
Relay output 1 × RO1, 1 form C (NO + NC), 2 A, 250 V AC / 30 V DC, galvanically isolated
Safe torque off Dual-channel STO terminals SGND / S+ / S1 / S2 (factory jumpers S1–S+, S2–S+)
Auxiliary voltage +24 V DC ±10%, max. 250 mA output; can instead accept external +24 V (max. 1000 mA incl. internal fan)
Other Cold-configuration port for CCA-01; one option-module slot; integrated icon-based operator panel
Not on board (N) No analog inputs, no analog output, no digital I/O DIO1/DIO2, no embedded Modbus RTU — add via the modules below.

Plug-in option modules (slot / side mount)

Module Option code What it adds
BMIO-01 +L538 DI3, DI4, DIO1, DIO2 (frequency/counter capable), 2× AI (0–10 V / 0–20 mA), 1× AO, embedded EIA-485 Modbus RTU — this is the factory-fitted “S” set
BIO-01 +L515 DI3–DI5, DIO1, 1× AI, 1× AO (combinable with a fieldbus module)
BREL-01 +L511 4 additional relay outputs RO4–RO7 (side option)
BAPO-01/02 +L534 External 24 V DC supply interface (side option)
BTAC-02/03 +L535 HTL/TTL encoder interface + external 24 V DC
BRES-01 +L516 Resolver interface (side option)
Analog channel ratings (when an I/O module is fitted): AI voltage 0–10 V (11 V max.), Rin 221.6 kΩ; AI current 0–20 mA (22 mA max.), Rin 137 Ω; inaccuracy ≤ 1.0% FS. AO: 0–20 mA into ≤ 500 Ω or 0–10 V into ≥ 200 kΩ.

Communication & Fieldbus Options (configured “C” builds / retrofit)

Ethernet FENA-21 (+K475) PROFINET / EtherNet/IP / Modbus TCP · FPNO-21 (+K492) two-port PROFINET IO · FEIP-21 (+K490) EtherNet/IP
Fieldbus FPBA-01 (+K454) PROFIBUS DP · FECA-01 (+K469) EtherCAT (2× RJ45) · FEPL-02 (+K470) Ethernet POWERLINK · FCAN-01 (+K457) / BCAN-11 (+K495) CANopen · FDNA-01 (+K451) DeviceNet · FCNA-01 (+K462) ControlNet
Serial (with BMIO-01) Embedded Modbus RTU, EIA-485, with termination/bias switch
Functional safety bus FSPS-21 PROFIsafe / FSCS-21 CIP Safety modules add STO + SS1-t over the bus
Mechanical / filters Optional UL Type 1 hood kit (R0–R2, 3AXD50000187034); external second-environment RFI EMC filters (e.g. RFI-xx series); external input chokes and V1K du/dt output filters available

Functional Safety — Safe Torque Off (STO), standard

Architecture Redundant two-channel STO (S1, S2 must both switch); single-channel use removes the SIL/PL classification; motor coasts to stop; channel mismatch > 200 ms trips FA81/FA82
Input levels 15–25 V DC (24 V +10% max.); ≥ 13 V read as “1”; input pulse tolerance 1 ms; activation contacts must switch within 200 ms of each other
Standards / levels (R1, 3-phase) IEC/EN 61800-5-2 STO · IEC 61508 SIL 3 · EN/IEC 62061 SIL CL 3 (SC 3) · EN ISO 13849-1 PL e, Category 3, HFT 1; IEC 61000-6-7 / IEC 61326-3-1 immunity
Quantitative data SFF > 99% · DC ≥ 90% · CCF 80 · MTTFD 2,210 years · PFH 7.65×10⁻⁹ 1/h · mission time TM 20 years (proof-test interval: 20 a high-demand / 10 a low-demand)
Response times STO reaction time (shortest detectable break) 1 ms; response 5 ms typical / 15 ms maximum; fault reaction = detection + 10 ms

Mechanical Data — Frame R1 (IP20 / UL open type)

Height H1 (mounting surface) 205 mm (8.07 in)
Height H2 (with PE extension plate) 223 mm (8.8 in)
Width W 70 mm (2.8 in)
Depth D 176 mm (6.9 in)
Weight ≈ 1.6 kg (3.5 lb)
Degree of protection IP20 / UL open type — cabinet installation required; optional UL Type 1 kit (hood)
Board protection Conformal-coated circuit boards as standard
Mounting / class Vertical DIN-rail/screw mount, bottom cable entry; protective class I; overvoltage category III (IEC 60664-1); mounting-hole spacing M1 50 mm / M2 191 mm

Environmental Conditions

Operating air temperature −10 … +50 °C (+14 … +122 °F), no frost, full ratings to 50 °C; R1–R3 derate 1% / 1 °C from +50 to +60 °C
Storage / transport (packaged) −40 … +70 °C (−40 … +158 °F, ±2%)
Relative humidity 5–95%, non-condensing (max. 60% in presence of corrosive gases)
Altitude 400/480 V units: 0–4000 m (13,123 ft); rated to 1000 m, output derating above 1000 m
Vibration / shock IEC 60068-2-6 sinusoidal 10–150 Hz, ±0.075 mm / 10 m·s⁻²; packaged transport shock ISTA 1A, max. 100 m·s⁻², 11 ms; 76 cm packaged free-fall
Contamination / gases Pollution degree 2 (IEC/EN 61800-5-1), no conductive dust; IEC 60721-3-3 chemical gases Class 3C2, solid particles Class 3S2; heated indoor controlled environment

Compliance, Approvals & EMC

Approvals / marks CE, cULus (UL 61800-5-1 / CSA C22.2 No. 274), RCM, EAC
EMC (this “040” build) Internal EN/IEC 61800-3 Category C3 filter fitted on 400 V drives (second environment); not for connection to public low-voltage residential networks
C2 option “042” high-filtering build (ACS380-042x) meets Category C2 for first environment; with C2 filter, frames R1–R4 allow up to 100 m motor cable in a C3 environment without external filters
Integrated protections Output short-circuit, DC over/undervoltage & mains loss, earth fault, drive/motor overtemperature, motor overload (IEC/UL 61800-5-1), motor stall, STO diagnostics, brake chopper/resistor supervision
Technical reference · ABB ACS380-040N-09A4-4 · Base variant · 4.0 kW, 9.4 A, 3-phase 380–480 V, Frame R1, IP20

Place your order before 14:00 for earliest possible shipment handover. With round-the-clock transit operated by our partnered global logistics providers, parcels reach most international destinations following routine customs processing. Economy shipping takes 5–8 business days, while express delivery arrives in 5–8 business days, both subject to customs clearance progress.Shipping fees will be charged for all orders under USD 500, and the exact shipping cost will be determined and collected by our logistics carriers. Shipments to remote international regions will incur additional courier surcharges to offset extra cross-border transportation costs.

Factory warranty service is not applicable to this industrial control equipment, and extended warranty packages are not provided for this item.

★★★★★

No reviews yet. Be the first to review this product!