SIMATIC S7-200 SMART CPU CR60s, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 36 DI 24V DC; 24DO RELAY 2A; POWER SUPPLY: AC, 85 - 264 V AC AT 47 - 63 HZ, PROGRAM/DATA MEMORY: 20 KB
Product Type: Industrial Automation Component
General
| Article number |
6ES7288-1CR60-0AA1 |
General information
| Product type designation |
CPU CR60s AC/DC/Relay |
Engineering with
| ● Programming package |
STEP 7 Micro/WIN SMART |
Installation type/mounting
| Rail mounting |
Yes; Standard - DIN rail |
Supply voltage
| Rated value (AC) |
230 V; 230 V AC (L1, N) |
| ● 120 V AC |
Yes; 85 to 132 V AC |
| ● 230 V AC |
Yes; 170 to 264 V AC |
| permissible range, lower limit (AC) |
85 V |
| permissible range, upper limit (AC) |
264 V |
| Reverse polarity protection |
No |
Line frequency
| ● permissible range, lower limit |
47 Hz |
| ● permissible range, upper limit |
63 Hz |
Load voltage L+
| ● Rated value (DC) |
24 V |
| ● permissible range, lower limit (DC) |
5 V |
| ● permissible range, upper limit (DC) |
250 V |
Input current
| Current consumption (rated value) |
100 mA; At 220 V AC |
| Current consumption, max. |
150 mA; At 220 V AC |
| Inrush current, max. |
16.3 A; at 264 V |
| ● for signal "0", max. (permissible quiescent current) |
1 mA |
| ● for signal "1", typ. |
4 mA |
Power loss
Storage
| Type of memory |
DDR |
| Flash |
Yes |
| RAM |
Yes |
| Micro Memory Card |
No |
CPU processing times
| for bit operations, typ. |
150 ns; / instruction |
| for word operations, typ. |
1.2 µs; / instruction |
| for floating point arithmetic, typ. |
3.6 µs; / instruction |
Hardware configuration
| Integrated power supply |
No |
Clock
| ● Type |
Software clock |
| ● Hardware clock (real-time) |
No |
Digital inputs
| Number of digital inputs |
36; Integrated |
| ● of which inputs usable for technological functions |
4; HSC: 4 @ 100 kHz single phase, 2 @ 50 kHz A/B phase |
| Sourcing/sinking input |
Yes |
Input voltage
| ● Type of input voltage |
DC |
| ● Rated value (DC) |
24 V |
| ● for signal "0" |
< 5 V DC |
| ● for signal "1" |
+15 to +30 V |
for standard inputs
| — Parameterizable |
Yes; 0.2 µs, 0.4 µs, 0.8 µs, 1.6 µs, 3.2 µs, 6.4 µs and 12.8 µs, selectable in 4 groups |
| — at "0" to "1", min. |
0.2 ms |
| — at "0" to "1", max. |
12.8 ms |
for interrupt inputs
Cable length
| ● shielded, max. |
500 m; 50m shielded for HSC inputs |
| ● unshielded, max. |
300 m |
| ● shielded, max. |
500 m |
| ● unshielded, max. |
150 m |
Digital outputs
| Number of digital outputs |
24; Relays |
Switching capacity of the outputs
| ● with resistive load, max. |
2 A |
| ● on lamp load, max. |
30 W; 30 W with DC, 200 W with AC |
Output delay with resistive load
| ● "0" to "1", max. |
10 ms; max. |
| ● "1" to "0", max. |
10 ms; max. |
Switching frequency
| ● of the pulse outputs, with resistive load, max. |
1 Hz |
Relay outputs
| ● Number of relay outputs |
24 |
| ● Number of operating cycles, max. |
100 000; mechanically 10 million, at rated load voltage 100 000 |
Interfaces
| Number of industrial Ethernet interfaces |
0 |
| Number of RS 485 interfaces |
1 |
| Optical interface |
No |
1. Interface
| Interface type |
RS 485 (max. 187.5 kbps) |
| Isolated |
Yes; 500 V AC or 707 V DC |
Interface types
| ● RS 485 |
Yes |
| ● Design of the connection |
9-pin sub D socket |
Protocols
| Supports protocol for PROFINET IO |
No |
| PROFIBUS |
No |
Protocols (Ethernet)
Interference immunity against discharge of static electricity
| ● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 |
Yes |
| — Test voltage at air discharge |
8 kV |
| — Test voltage at contact discharge |
4 kV |
Interference immunity against high-frequency electromagnetic fields
| ● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 |
Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) |
| — Frequency range of the RF radiation |
10 V/m for 80 MHz ~ 1 GHz, 3 V/m for 1.4 GHz ~ 2 GHz, 3 V/m for 87 MHz ~ 108 MHz, 174 MHz ~ 230 MHz, 470 MHz ~ 790 MHz, 1.4 GHz ~ 2 GHz, 1 V/m for 2 GHz ~ 2.7 GHz |
Interference immunity to cable-borne interference
| ● Interference immunity on supply lines acc. to IEC 61000-4-4 |
Yes; 2 kV acc. to IEC 61000-4-4, burst |
| ● Interference immunity on signal cables acc. to IEC 61000-4-4 |
Yes; ±2 kV acc. to IEC 61000-4-4, Burst |
Interference immunity against voltage surge
| ● Interference immunity on supply lines acc. to IEC 61000-4-5 |
Yes; ±1 kV (acc. to IEC 61000-4-5; 1995; surge symm.), ±2 kV (acc. to IEC 61000-4-5; 1995; surge asymm.), no external protective circuit required |
● asymmetric interference
| — Test voltage on supply cables |
2 kV |
| — Test voltage on signal cables >30m |
2 kV |
Interference immunity against conducted variable disturbance induced by high-frequency fields
| ● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 |
Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
Emission of radio interference acc. to EN 55 011
| ● Limit class A, for use in industrial areas |
Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Emission of conducted and non-conducted interference
| ● Interference emission via line/AC current cables |
EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Degree and class of protection
| IP degree of protection |
IP20 |
Standards, approvals, certificates
Free fall
| ● Fall height, max. |
0.5 m; five times, in product package |
Ambient temperature during operation
| ● min. |
0 °C |
| ● max. |
55 °C |
| ● horizontal installation, min. |
0 °C |
| ● horizontal installation, max. |
55 °C |
| ● vertical installation, min. |
0 °C |
| ● vertical installation, max. |
45 °C |
Ambient temperature during storage/transportation
| ● min. |
-40 °C |
| ● max. |
70 °C |
Air pressure acc. to IEC 60068-2-13
| ● Storage/transport, min. |
660 hPa |
| ● Storage/transport, max. |
1 080 hPa |
Altitude during operation relating to sea level
| ● Installation altitude, min. |
-1 000 m |
| ● Installation altitude, max. |
2 000 m |
Relative humidity
| ● Operation at 25 ℃ without condensation, max. |
95 % |
Programming language
| — LAD |
Yes |
| — FBD |
Yes |
| — STL |
Yes |
Dimensions
| Width |
175 mm |
| Height |
100 mm |
| Depth |
81 mm |
Weights
| Weight, approx. |
605 g; approx. |
Classifications
| Version |
Classification |
| eClass |
16 |
| eClass |
14 |
| eClass |
12 |
| eClass |
9.1 |
| eClass |
9 |
| eClass |
8 |
| eClass |
7.1 |
| eClass |
6 |
| ETIM |
10 |
| ETIM |
9 |
| ETIM |
8 |
| ETIM |
7 |
| IDEA |
4 |
| UNSPSC |
15 |
General Product Approval
| EU declaration of conformity |
Yes |
| UK Declaration of Conformity |
Yes |
| EAC |
Yes |
| China RoHS |
Yes |
| EU declaration of conformity |
Yes |
| UK Declaration of Conformity |
Yes |
| last modified: |
8/24/2025 |
Applications
This Industrial Automation Component is designed for industrial automation applications, offering reliable performance and compatibility with Siemens automation systems. Suitable for manufacturing, process control, and building automation environments.