{"product_id":"x67di1371","title":"B\u0026R X67DI1371 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X67 System \u0026gt; Digital input modules\u003c\/p\u003e\n\u003cp\u003eFor all standard sensors with M8 connectors Extremely short cycle times Integrated sensor supply with short circuit protection The module is a digital input module for 24 VDC .\u003c\/p\u003e\n\u003cp\u003eIt is equipped with 8 inputs for a sink input circuit.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 8 digital inputs 24 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eI\/O power supply = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eConnection type\u003c\/li\u003e\n\u003cli\u003eX2X Link = M12, B-coded\u003c\/li\u003e\n\u003cli\u003eInputs = 8x M8, 3-pin\u003c\/li\u003e\n\u003cli\u003eI\/O power supply = M8, 4-pin\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1 W\u003c\/li\u003e\n\u003cli\u003eX2X Link power supply = 0.75 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1434\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, supply voltage, bus function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eSensor power supply = Max. 12 W\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eVoltage range = 18 to 30 VDC\u003c\/li\u003e\n\u003cli\u003eIntegrated protective function = Reverse polarity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤100 μs\u003c\/li\u003e\n\u003cli\u003eSoftware = 1 ms\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput characteristics per EN 61131-2 = Type 1\u003c\/li\u003e\n\u003cli\u003eInput voltage = 18 to 30 VDC\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Typ. 7 mA\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput resistance = Typ. 3 kΩ\u003c\/li\u003e\n\u003cli\u003eSensor power supply = 0.5 A summation current\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSensor power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage = I\/O power supply minus voltage drop for short-circuit protection\u003c\/li\u003e\n\u003cli\u003eVoltage drop for short-circuit protection at 500 mA = Max. 2 VDC\u003c\/li\u003e\n\u003cli\u003eSummation current = Max. 0.5 A\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eAny = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions\u003c\/li\u003e\n\u003cli\u003eWidth = 53 mm\u003c\/li\u003e\n\u003cli\u003eHeight = 85 mm\u003c\/li\u003e\n\u003cli\u003eDepth = 42 mm\u003c\/li\u003e\n\u003cli\u003eTorque for connections\u003c\/li\u003e\n\u003cli\u003eM8 = Max. 0.4 Nm\u003c\/li\u003e\n\u003cli\u003eM12 = Max. 0.6 Nm\u003c\/li\u003e\n\u003cli\u003eWeight = 170 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160974610685,"sku":"X67DI1371","price":637.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X67DI1371.jpg?v=1785724383","url":"https:\/\/shly-plc.com\/products\/x67di1371","provider":"Lianyou PLC","version":"1.0","type":"link"}