{"product_id":"x67am1223","title":"B\u0026R X67AM1223 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X67 System \u0026gt; Analog mixed modules\u003c\/p\u003e\n\u003cp\u003e2 analog inputs, 2 analog outputs, ±10 V each Open circuit detection on the inputs Configurable digital input filters Very short cycle times Optimal shield grounding on all channels The module is equipped with 2 inputs and 2 outputs with 12-bit digital converter resolution.\u003c\/p\u003e\n\u003cp\u003eThe range of the input\/output signal is ±10 V .\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 analog inputs, 2 analog outputs, each ±10 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eInputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eI\/O power supply = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eConnection type\u003c\/li\u003e\n\u003cli\u003eX2X Link = M12, B-coded\u003c\/li\u003e\n\u003cli\u003eInputs\/Outputs = 4x M12, A-coded\u003c\/li\u003e\n\u003cli\u003eI\/O power supply = M8, 4-pin\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 3 W\u003c\/li\u003e\n\u003cli\u003eX2X Link power supply = 0.75 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA IIA T5 Gc IP67, Ta = 0 - Max. 60°C TÜV 05 ATEX 7201X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x1465\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, supply voltage, bus function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eSensor\/Actuator power supply = Max. 12 W\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eVoltage range = 18 to 30 VDC\u003c\/li\u003e\n\u003cli\u003eIntegrated protective function = Reverse polarity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSensor\/Actuator power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage = I\/O power supply minus voltage drop for short-circuit protection\u003c\/li\u003e\n\u003cli\u003eVoltage drop for short-circuit protection at 0.5 A = Max. 2 VDC\u003c\/li\u003e\n\u003cli\u003eSummation current = Max. 0.5 A\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput format\u003c\/li\u003e\n\u003cli\u003eVoltage = INT 0x8001 - 0x7FFF \/ 1 LSB = 0x0010 = 4.882 mV\u003c\/li\u003e\n\u003cli\u003eOutput of digital value during overload\u003c\/li\u003e\n\u003cli\u003eUndershoot = 0x8001\u003c\/li\u003e\n\u003cli\u003eOvershoot = 0x7FFF\u003c\/li\u003e\n\u003cli\u003eMax. error\u003c\/li\u003e\n\u003cli\u003eGain = 0.1%\u003c\/li\u003e\n\u003cli\u003eOffset = 0.05%\u003c\/li\u003e\n\u003cli\u003eCommon-mode rejection\u003c\/li\u003e\n\u003cli\u003eDC = \u0026gt;50 dB\u003c\/li\u003e\n\u003cli\u003e50 Hz = \u0026gt;50 dB\u003c\/li\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eCutoff frequency = 300 Hz\u003c\/li\u003e\n\u003cli\u003eSlope = 40 dB\u003c\/li\u003e\n\u003cli\u003eInput = ±10 V\u003c\/li\u003e\n\u003cli\u003eInput type = Differential input\u003c\/li\u003e\n\u003cli\u003eDigital converter resolution = 12-bit\u003c\/li\u003e\n\u003cli\u003eConversion time = 400 µs for both inputs\u003c\/li\u003e\n\u003cli\u003eOutput format = INT\u003c\/li\u003e\n\u003cli\u003eInput impedance in signal range = 20 MΩ\u003c\/li\u003e\n\u003cli\u003eInput protection = Protection against wiring with supply voltage\u003c\/li\u003e\n\u003cli\u003ePermissible input signal = Max. ±30 V\u003c\/li\u003e\n\u003cli\u003eConversion procedure = Successive approximation\u003c\/li\u003e\n\u003cli\u003eMax. gain drift = 0.011%\/°C\u003c\/li\u003e\n\u003cli\u003eMax. offset drift = 0.009%\/°C\u003c\/li\u003e\n\u003cli\u003eCommon-mode range = ±11 V\u003c\/li\u003e\n\u003cli\u003eCrosstalk between channels = \u0026lt;-70 dB\u003c\/li\u003e\n\u003cli\u003eNonlinearity = \u0026lt;0.1%\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eShort-circuit proof\u003c\/li\u003e\n\u003cli\u003eCurrent limiting = ±40 mA\u003c\/li\u003e\n\u003cli\u003eTo GND = Yes\u003c\/li\u003e\n\u003cli\u003eTo sensor or I\/O power supply = Yes\u003c\/li\u003e\n\u003cli\u003eMax. error at 25°C and 10 kΩ load\u003c\/li\u003e\n\u003cli\u003eGain = 0.15%\u003c\/li\u003e\n\u003cli\u003eOffset = 0.05%\u003c\/li\u003e\n\u003cli\u003eOutput = ±10 V\u003c\/li\u003e\n\u003cli\u003eDigital converter resolution = 12-bit\u003c\/li\u003e\n\u003cli\u003eConversion time = 400 µs for both outputs\u003c\/li\u003e\n\u003cli\u003eSettling time on output change over entire range = Approx. 1 ms\u003c\/li\u003e\n\u003cli\u003eSwitch on\/off behavior = Internal enable relay for startup and errors\u003c\/li\u003e\n\u003cli\u003eOutput protection = Protection against wiring with supply voltage, short-circuit proof\u003c\/li\u003e\n\u003cli\u003eOutput format = INT 0x8001 - 0x7FFF \/ 1 LSB = 0x0010 = 4.882 mV\u003c\/li\u003e\n\u003cli\u003eLoad per channel = Max. ±10 mA, load ≥ 1 kΩ\u003c\/li\u003e\n\u003cli\u003eOutput filter = First-order low-pass filter \/ cutoff frequency 2.5 kHz\u003c\/li\u003e\n\u003cli\u003eMax. gain drift = 0.012%\/°C\u003c\/li\u003e\n\u003cli\u003eMax. offset drift = 0.015%\/°C\u003c\/li\u003e\n\u003cli\u003eError caused by load change = Max. 0.01%, from 10 MΩ → 1 kΩ, resistive\u003c\/li\u003e\n\u003cli\u003eNonlinearity = \u0026lt;0.15%\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003eOutput response when the power supply is switched on\/off = An enable relay is switched on at a defined value ≠ 0, default setting = 10 kΩ to GND\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from bus Channel not isolated from channel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eAny = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eDerating = -\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160975069437,"sku":"X67AM1223","price":1716.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X67AM1223.jpg?v=1785724375","url":"https:\/\/shly-plc.com\/products\/x67am1223","provider":"Lianyou PLC","version":"1.0","type":"link"}