{"product_id":"x20so6300","title":"B\u0026R X20SO6300 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Safety technology \u0026gt; X20 System \u0026gt; Digital output modules\u003c\/p\u003e\n\u003cp\u003e6 safe digital outputs with 0.2 A Source circuit Output type B Integrated output protection This module is equipped with 6 safe digital outputs.\u003c\/p\u003e\n\u003cp\u003eThe nominal output current is 0.2 A.\u003c\/p\u003e\n\u003cp\u003eThe module can be used for controlling actuators in safety-related applications up to PL e or SIL 3.\u003c\/p\u003e\n\u003cp\u003eThe outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles.\u003c\/p\u003e\n\u003cp\u003eThe \"high-side high-side\" variant (output type B) is required for actuators with reference potential (e.g.\u003c\/p\u003e\n\u003cp\u003eEnable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case.\u003c\/p\u003e\n\u003cp\u003eSafe digital output channels provide protection against automatic restart when network errors occur.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for X20 12-pin terminal blocks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 6 safe type B1 digital outputs, 24 VDC, 0.2 A, OSSD \u0026lt;10 µs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOutputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eBlackout mode\u003c\/li\u003e\n\u003cli\u003eScope = Module\u003c\/li\u003e\n\u003cli\u003eFunction = Module functionality\u003c\/li\u003e\n\u003cli\u003eStandalone mode = No\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.32 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.4 W\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eChannel - Bus = Yes\u003c\/li\u003e\n\u003cli\u003eChannel - Channel = No\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eFunctional safety = cULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013\u003c\/li\u003e\n\u003cli\u003eFunctional safety = IEC 61508, up to SIL 3 IEC 62061, up to SIL 3 ISO 13849-1, up to Cat. 4 \/ PL e IEC 61511, up to SIL 3\u003c\/li\u003e\n\u003cli\u003eFunctional safety = EN 50156-1\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment cULus E537419 Engine generator controller\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xB815\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = 1.128\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = See section \"Safety characteristics\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eVoltage range = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eIntegrated protective function = Reverse polarity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafe digital outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuantity = 6\u003c\/li\u003e\n\u003cli\u003eVariant = FET, 2x positive switching, type B1, output level readable\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eNominal output current = 0.2 A\u003c\/li\u003e\n\u003cli\u003eTotal nominal current = 1.2 A\u003c\/li\u003e\n\u003cli\u003eOutput protection = See section \"Inrush current behavior for output channels\".\u003c\/li\u003e\n\u003cli\u003eBraking voltage when switching off inductive loads = Max. 45 VDC\u003c\/li\u003e\n\u003cli\u003eError detection time = 1 s\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003ePeak short-circuit current = See section \"Inrush current behavior for output channels\".\u003c\/li\u003e\n\u003cli\u003eLeakage current when the output is switched off = \u0026lt;100 µA\u003c\/li\u003e\n\u003cli\u003eR DS(on) = 4.7 Ω\u003c\/li\u003e\n\u003cli\u003eSwitching voltage = I\/O power supply minus voltage drop due to R DS(on)\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = See section \"Inrush current behavior for output channels\".\u003c\/li\u003e\n\u003cli\u003eTest pulse length = Max. 10 µs\u003c\/li\u003e\n\u003cli\u003eMax. capacitive load = 100 nF\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent on loss of ground\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI OUT = \u0026lt;100 µA\u003c\/li\u003e\n\u003cli\u003eI GND = \u0026lt;70 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level = 0 to 2000 m, no limitation\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = 0 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = 0 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 25 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160975692029,"sku":"X20SO6300","price":1196.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20SO6300.jpg?v=1785724332","url":"https:\/\/shly-plc.com\/products\/x20so6300","provider":"Lianyou PLC","version":"1.0","type":"link"}