{"product_id":"x20sc2432","title":"B\u0026R X20SC2432 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Safety technology \u0026gt; X20 System \u0026gt; Digital mixed modules\u003c\/p\u003e\n\u003cp\u003e2 safe digital inputs, sink circuit 2 pulse outputs Software input filter configurable for each channel 2 safe relay outputs Output type \"Relay\" Relay module for 48 VAC \/ 24 VDC Switching current 6 A Normally open contact Single-channel isolated outputs The module is equipped with 2 safe digital inputs and 2 safe relay outputs.\u003c\/p\u003e\n\u003cp\u003eIt is designed for a nominal voltage of 24 VDC.\u003c\/p\u003e\n\u003cp\u003eThe module can be used to read digital signals and for floating control of actuators in safety-related applications up to PL e or SIL 3.\u003c\/p\u003e\n\u003cp\u003eThe module is equipped with filters that are individually configurable for switch-on and switch-off behavior.\u003c\/p\u003e\n\u003cp\u003eThe module also provides pulse signals for diagnosing the sensor line. Safety relays are installed in the module.\u003c\/p\u003e\n\u003cp\u003eThe positively driven feedback contacts are evaluated internally by the module.\u003c\/p\u003e\n\u003cp\u003eSafe digital output channels provide protection against automatic restart when network errors occur.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for X20 12-pin terminal blocks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 safe type A digital inputs, 2 pulse outputs, 24 VDC, 2 relays with 1 normally open contact each, 48 VAC \/ 6 A, 24 VDC \/ 6 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOutputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eInputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eBlackout mode\u003c\/li\u003e\n\u003cli\u003eScope = Module\u003c\/li\u003e\n\u003cli\u003eFunction = Module functionality\u003c\/li\u003e\n\u003cli\u003eStandalone mode = No\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.26 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.15 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W]\u003c\/li\u003e\n\u003cli\u003eRelay outputs = 1.44\u003c\/li\u003e\n\u003cli\u003ePulse outputs = 0.1\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eChannel - Bus = Yes\u003c\/li\u003e\n\u003cli\u003eChannel - Channel = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eRelays\u003c\/li\u003e\n\u003cli\u003eEN 50155 = Yes\u003c\/li\u003e\n\u003cli\u003eEN 61810-3 = Yes\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eFunctional safety = cULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013\u003c\/li\u003e\n\u003cli\u003eFunctional safety = IEC 61508, up to SIL 3 IEC 62061, up to SIL 3 ISO 13849-1, up to Cat. 4 \/ PL e IEC 61511, up to SIL 3\u003c\/li\u003e\n\u003cli\u003eFunctional safety = EN 50156-1\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment cULus E537419 Engine generator controller\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: A (0 to 45°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC21B Temperature: 5 - 45°C Vibration: 0.7 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xA7A4\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = See section \"Safety characteristics\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eVoltage range = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eIntegrated protective function = Reverse polarity protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafe digital inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤150 μs\u003c\/li\u003e\n\u003cli\u003eSoftware = Configurable between 0 and 500 ms\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eVariant = Type A\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput characteristics per EN 61131-2 = Type 1\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Min. 2 mA to max. 4.59 mA\u003c\/li\u003e\n\u003cli\u003eInput resistance = Min. 5.23 kΩ\u003c\/li\u003e\n\u003cli\u003eError detection time = 100 ms\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003cli\u003eLine length between signal source (pulse output or external signal) and input = Max. 60 m with unshielded line Max. 400 m with shielded line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRelay outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003e0 → 1 = \u0026lt;50 ms\u003c\/li\u003e\n\u003cli\u003e1 → 0 = \u0026lt;50 ms\u003c\/li\u003e\n\u003cli\u003eMax. switching capacity\u003c\/li\u003e\n\u003cli\u003eAC1 = 48 VAC \/ 6 A\u003c\/li\u003e\n\u003cli\u003eAC15 = 48 VAC \/ 3 A\u003c\/li\u003e\n\u003cli\u003eDC1 = 24 VDC \/ 6 A\u003c\/li\u003e\n\u003cli\u003eDC13 = 24 VDC \/ 5 A \/ 0.1 Hz\u003c\/li\u003e\n\u003cli\u003eUL 508 = B300 \/ R300\u003c\/li\u003e\n\u003cli\u003eQuantity = 2\u003c\/li\u003e\n\u003cli\u003eVariant = Relay \/ Normally open contact, internal high-side and low-side control\u003c\/li\u003e\n\u003cli\u003eNominal output current = 5 mA to 6 A\u003c\/li\u003e\n\u003cli\u003eDiagnostic status = Contact position determined by positively driven contacts\u003c\/li\u003e\n\u003cli\u003eMax. switching frequency = See section \"Inrush current behavior for output channels\".\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = Safe disconnection of 300 VAC per EN 50178\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and channel = 48 VAC\u003c\/li\u003e\n\u003cli\u003eContact resistance (without terminal block) = 20 mΩ\u003c\/li\u003e\n\u003cli\u003eContact service life = See \"Contact service life\".\u003c\/li\u003e\n\u003cli\u003eShort-circuit\/Overload protection = External 6 A gL\/gG fuse (melting fuse), LS automat C characteristic 1.6 A\u003c\/li\u003e\n\u003cli\u003eSwitching voltage range = 5 to 24 VDC, 5 to 48 VAC\u003c\/li\u003e\n\u003cli\u003eCoil voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes, 1000 A (with specified short-circuit\/overload protection)\u003c\/li\u003e\n\u003cli\u003eMax. inrush current = 30 A for 20 ms\u003c\/li\u003e\n\u003cli\u003eOvervoltage category per EN 60664-1 = II\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160991977725,"sku":"X20SC2432","price":1327.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20SC2432.jpg?v=1785724256","url":"https:\/\/shly-plc.com\/products\/x20sc2432","provider":"Lianyou PLC","version":"1.0","type":"link"}