{"product_id":"x20sa4430","title":"B\u0026R X20SA4430 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Safety technology \u0026gt; X20 System \u0026gt; Analog input modules\u003c\/p\u003e\n\u003cp\u003e2 safe analog input pairs for current measurement 0.5 to 25 mA 24-bit digital converter resolution Channels individually galvanically isolated Sensor power supplies galvanically isolated Input filter configurable The module is equipped with 2 safe analog input pairs for current measurement.\u003c\/p\u003e\n\u003cp\u003eEach input pair has its own sensor power supply.\u003c\/p\u003e\n\u003cp\u003eThe channels with their respective sensor supplies are electrically isolated from each other.\u003c\/p\u003e\n\u003cp\u003eIt can be used to capture current signals in the range from 0.5 to 25 mA.\u003c\/p\u003e\n\u003cp\u003eThe safe analog input module is suitable for safely acquiring current signals for safety-related applications up to PL e or SIL 3.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for X20 16-pin terminal blocks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2x 2 safe type A analog inputs, 0.5 to 25 mA, channels individually galvanically isolated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eInputs = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eBlackout mode\u003c\/li\u003e\n\u003cli\u003eScope = Module\u003c\/li\u003e\n\u003cli\u003eFunction = Module functionality\u003c\/li\u003e\n\u003cli\u003eStandalone mode = No\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.25 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.7 W\u003c\/li\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eChannel - Bus = Yes\u003c\/li\u003e\n\u003cli\u003eChannel - Channel = Yes\u003c\/li\u003e\n\u003cli\u003eChannel pair - Channel pair = Yes\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eFunctional safety = cULus FSPC E361559 Energy and industrial systems Certified for functional safety ANSI UL 1998:2013\u003c\/li\u003e\n\u003cli\u003eFunctional safety = IEC 61508:2010, SIL 3 EN 62061:2005\/A2:2015, SIL 3 EN ISO 13849-1:2015, Cat. 4 \/ PL e IEC 61511:2004, SIL 3\u003c\/li\u003e\n\u003cli\u003eFunctional safety = EN 50156-1:2004\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment cULus E537419 Engine generator controller\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: A (0 to 45°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC21B Temperature: 5 - 45°C Vibration: 0.7 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xB8B5\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = 0.36\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = See section \"Safety characteristics\".\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eVoltage range = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafe analog inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermissible input signal\u003c\/li\u003e\n\u003cli\u003eVoltage = Max. 30.5 V\u003c\/li\u003e\n\u003cli\u003eMax. error at 25°C\u003c\/li\u003e\n\u003cli\u003eGain\u003c\/li\u003e\n\u003cli\u003e0.5 to \u0026lt;4 mA = \u0026lt;0.3%\u003c\/li\u003e\n\u003cli\u003e4 to 25 mA = \u0026lt;0.08%\u003c\/li\u003e\n\u003cli\u003eOffset\u003c\/li\u003e\n\u003cli\u003e0.5 to \u0026lt;4 mA = \u0026lt;2 µA\u003c\/li\u003e\n\u003cli\u003e4 to 25 mA = \u0026lt;6.3 µA\u003c\/li\u003e\n\u003cli\u003eMax. gain drift\u003c\/li\u003e\n\u003cli\u003e0.5 to \u0026lt;4 mA = \u0026lt;1.225 µA\/°C\u003c\/li\u003e\n\u003cli\u003e4 to 25 mA = \u0026lt;1.225 µA\/°C\u003c\/li\u003e\n\u003cli\u003eMax. offset drift\u003c\/li\u003e\n\u003cli\u003e0.5 to \u0026lt;4 mA = \u0026lt;0.735 µA\/°C\u003c\/li\u003e\n\u003cli\u003e4 to 25 mA = \u0026lt;0.735 µA\/°C\u003c\/li\u003e\n\u003cli\u003eCommon-mode rejection\u003c\/li\u003e\n\u003cli\u003eDC = \u0026gt;70 dB\u003c\/li\u003e\n\u003cli\u003e50 Hz = \u0026gt;70 dB\u003c\/li\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = First-order low-pass filter \/ cutoff frequency 500 Hz\u003c\/li\u003e\n\u003cli\u003eSoftware = Sinc 3 filter\u003c\/li\u003e\n\u003cli\u003eTest voltage\u003c\/li\u003e\n\u003cli\u003eChannel - Bus = 500 VDC\u003c\/li\u003e\n\u003cli\u003eChannel pair - Channel pair = 500 VDC\u003c\/li\u003e\n\u003cli\u003eChannel - Ground = 500 VDC\u003c\/li\u003e\n\u003cli\u003eSafety-related accuracy per channel\u003c\/li\u003e\n\u003cli\u003eCat. 3 = 0.184 mA\u003c\/li\u003e\n\u003cli\u003eCat. 4 = 0.49 mA\u003c\/li\u003e\n\u003cli\u003eQuantity = 2 safe input channel pairs\u003c\/li\u003e\n\u003cli\u003eVariant = Type A\u003c\/li\u003e\n\u003cli\u003eInput type = Differential input\u003c\/li\u003e\n\u003cli\u003eDigital converter resolution = 24-bit\u003c\/li\u003e\n\u003cli\u003eConversion time = See chapter \"I\/O update time\".\u003c\/li\u003e\n\u003cli\u003eOutput format = SAFEINT\u003c\/li\u003e\n\u003cli\u003eLoad = Up to hardware revision D3: 230 to 420 Ω, hardware revision E0 or later: 185 to 245 Ω\u003c\/li\u003e\n\u003cli\u003eInput protection = Protection against external supply voltages and overcurrent\u003c\/li\u003e\n\u003cli\u003eOpen-circuit detection = Yes, using software\u003c\/li\u003e\n\u003cli\u003eConversion procedure = Sigma-delta\u003c\/li\u003e\n\u003cli\u003eCommon-mode range = Between the inputs ±50 V\u003c\/li\u003e\n\u003cli\u003eNonlinearity = \u0026lt;0.003%\u003c\/li\u003e\n\u003cli\u003eMeasurement range = 0.5 to 25 mA\u003c\/li\u003e\n\u003cli\u003eResolution = 1 µA\/LSB\u003c\/li\u003e\n\u003cli\u003eOverload detection = Yes, using software\u003c\/li\u003e\n\u003cli\u003eFilter time = Configurable between 1 and 66.7 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSensor power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation\u003c\/li\u003e\n\u003cli\u003eSensor power supply - Channel = No\u003c\/li\u003e\n\u003cli\u003eSensor power supply - Sensor power supply = Yes\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 29 VDC ±5%\u003c\/li\u003e\n\u003cli\u003eNominal output current = Max. 60 mA\u003c\/li\u003e\n\u003cli\u003eShort-circuit proof = Yes, continuous\u003c\/li\u003e\n\u003cli\u003eR DS(on) = 50 Ω\u003c\/li\u003e\n\u003cli\u003eBehavior on short circuit = Voltage cutoff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level = 0 to 2000 m, no limitation\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160977035517,"sku":"X20SA4430","price":1993.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20SA4430.jpg?v=1785724242","url":"https:\/\/shly-plc.com\/products\/x20sa4430","provider":"Lianyou PLC","version":"1.0","type":"link"}