{"product_id":"x20ps9600","title":"B\u0026R X20PS9600 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLC systems \u0026gt; X20 System \u0026gt; System modules for Compact-S PLC\u003c\/p\u003e\n\u003cp\u003eSupply for Compact-S CPU, X2X Link and internal I\/O power supply Galvanic isolation of supply and CPU \/ X2X Link power supply Redundancy of the CPU \/ X2X Link power supply possible through parallel operation of multiple power supply modules RS232 configurable as an online interface CAN bus The power supply module is used together with an X20 Compact-S PLC.\u003c\/p\u003e\n\u003cp\u003eIt has a feed for the Compact-S PLC, X2X Link and the internal I\/O power supply.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply module = 24 VDC power supply module for Compact-S PLC, X2X Link power supply and I\/O\u003c\/li\u003e\n\u003cli\u003eInterfaces = 1x RS232, 1x RS485, 1x CAN bus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eCAN bus data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eRS232 data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eRS485 data transfer = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003eOverload = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 0.6 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0xEB03\u003c\/li\u003e\n\u003cli\u003eStatus indicators = Overload, operating state, module status, RS232, RS485, CAN bus\u003c\/li\u003e\n\u003cli\u003ePower consumption for X2X Link power supply = 1.42 W\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCPU \/ X2X Link power supply input\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current = Max. 0.7 A\u003c\/li\u003e\n\u003cli\u003eFuse = Integrated, cannot be replaced\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCPU \/ X2X Link power supply output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output power = 7 W\u003c\/li\u003e\n\u003cli\u003eParallel connection = Yes\u003c\/li\u003e\n\u003cli\u003eRedundant operation = Yes\u003c\/li\u003e\n\u003cli\u003eOverload characteristics = Short-circuit proof, temporary overload\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eFuse = Required line fuse: Max. 10 A, slow-blow\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection = No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput I\/O power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eBehavior on short circuit = Required line fuse\u003c\/li\u003e\n\u003cli\u003ePermissible contact load = 10 A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInterfaces\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInterface IF1\u003c\/li\u003e\n\u003cli\u003eSignal = RS232 or RS485\u003c\/li\u003e\n\u003cli\u003eVariant = Connection made using 12-pin terminal block X20TB12\u003c\/li\u003e\n\u003cli\u003eTransfer rate = Max. 115.2 kbit\/s\u003c\/li\u003e\n\u003cli\u003eInterface IF3\u003c\/li\u003e\n\u003cli\u003eSignal = CAN bus\u003c\/li\u003e\n\u003cli\u003eTransfer rate = Max. 1 Mbit\/s\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = PLC\/X2X Link supply isolated from PLC\/X2X Link power supply I\/O supply not isolated from I\/O power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Reduction of ambient temperature by 0.5°C per 100 m\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x Compact-S PLC base X20BB5x, X20BB6x or X20BB7x separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984831009021,"sku":"X20PS9600","price":391.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20PS9600.jpg?v=1785724529","url":"https:\/\/shly-plc.com\/products\/x20ps9600","provider":"Lianyou PLC","version":"1.0","type":"link"}