{"product_id":"x20ds1319","title":"B\u0026R X20DS1319 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Digital signal processing and preparation\u003c\/p\u003e\n\u003cp\u003e4 digital input channels 4 digital channels, configurable as inputs or outputs 1 universal counter pair (2 event counters, AB counters or up\/down counters) Linear movement generator (A\/B, direction\/frequency) with up to 2 reference pulses SSI absolute encoder NetTime timestamp: Input data, target position, position change, edge change, counter change This module is a multifunction digital signal processor module.\u003c\/p\u003e\n\u003cp\u003eIt can be used extremely flexibly for a wide variety of tasks involving digital signal processing or digital signal generation.\u003c\/p\u003e\n\u003cp\u003eTwo primary example applications include controlling stepper output stages with pulse and direction signals or using as encoder emulation.\u003c\/p\u003e\n\u003cp\u003eIn this application, for example, frequency inverters or servo axes with the speed follow function can follow a real or virtual master axis.\u003c\/p\u003e\n\u003cp\u003eAn additional essential feature is the module's integrated timestamp function.\u003c\/p\u003e\n\u003cp\u003eIt allows counter ramps curves to be generated virtually independently of bus cycle times during encoder emulation, for example.\u003c\/p\u003e\n\u003cp\u003eOnly the target counter value and moment when it should be reached are transferred.\u003c\/p\u003e\n\u003cp\u003eThe module automatically generates the corresponding counter values at the appropriate time, precisely in microsecond resolution and independently of the bus clock.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 4 digital input channels, 4 digital channels configurable as inputs or outputs, 1 universal counter pair (2 event counters, AB counter or up\/down counter), linear movement generator (A\/B, direction\/frequency) with up to two reference pulses, SSI absolute encoder, relative or absolute moments of input edges with μs resolution, time-triggered I\/O, I\/O oversampling\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOutputs = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.01 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = 1.5 W\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x2547\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = -\u003c\/li\u003e\n\u003cli\u003eType of signal lines = Shielded lines must be used for all signal lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLinear motion generator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eEncoder outputs = 24 V, asymmetrical (A\/B, direction\/frequency)\u003c\/li\u003e\n\u003cli\u003eCounter size = 16\/32-bit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital inputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput filter\u003c\/li\u003e\n\u003cli\u003eHardware = ≤2 µs\u003c\/li\u003e\n\u003cli\u003eSoftware = -\u003c\/li\u003e\n\u003cli\u003eSwitching threshold\u003c\/li\u003e\n\u003cli\u003eLow = \u0026lt;5 VDC\u003c\/li\u003e\n\u003cli\u003eHigh = \u0026gt;15 VDC\u003c\/li\u003e\n\u003cli\u003eQuantity = 4 + 4, configuration as input or output using software\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eInput voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eInput current at 24 VDC = Approx. 1.3 mA\u003c\/li\u003e\n\u003cli\u003eInput circuit = Sink\u003c\/li\u003e\n\u003cli\u003eInput resistance = 18.4 kΩ\u003c\/li\u003e\n\u003cli\u003eAdditional functions = SSI absolute encoder, universal counter pair, latch function for universal counter pair\u003c\/li\u003e\n\u003cli\u003eInput frequency = 100 kHz\u003c\/li\u003e\n\u003cli\u003eOverload characteristics of encoder power supply = Short-circuit proof, overload-proof\u003c\/li\u003e\n\u003cli\u003eInsulation voltage between channel and bus = 500 V eff\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSSI absolute encoder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eCounter size = Up to 32-bit depending on encoder\u003c\/li\u003e\n\u003cli\u003eMax. transfer rate = 125 kbit\/s\u003c\/li\u003e\n\u003cli\u003eEncoder power supply = Module-internal, max. 600 mA\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 V, asymmetrical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal counter pair\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEvaluation\u003c\/li\u003e\n\u003cli\u003eAB counter = 4x\u003c\/li\u003e\n\u003cli\u003eEvent counters = 2x\u003c\/li\u003e\n\u003cli\u003eUp\/Down counter = 2x\u003c\/li\u003e\n\u003cli\u003eQuantity = 1\u003c\/li\u003e\n\u003cli\u003eOperating modes = 2x event counter, up\/down counter, AB counter\u003c\/li\u003e\n\u003cli\u003eEncoder inputs = 24 V, asymmetrical\u003c\/li\u003e\n\u003cli\u003eCounter size = 16\/32-bit\u003c\/li\u003e\n\u003cli\u003eInput frequency = Max. 100 kHz\u003c\/li\u003e\n\u003cli\u003eSignal form = Square wave pulse\u003c\/li\u003e\n\u003cli\u003eEncoder power supply = Module-internal, max. 600 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003e0 → 1 = \u0026lt;2 µs\u003c\/li\u003e\n\u003cli\u003e1 → 0 = \u0026lt;2 µs\u003c\/li\u003e\n\u003cli\u003eSwitching frequency\u003c\/li\u003e\n\u003cli\u003eResistive load = Max. 125 kHz\u003c\/li\u003e\n\u003cli\u003eInductive load = See section \"Switching inductive loads\".\u003c\/li\u003e\n\u003cli\u003eQuantity = Up to 4, configuration as input or output using software\u003c\/li\u003e\n\u003cli\u003eExecution = Push \/ Pull \/ Push-Pull\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 24 VDC\u003c\/li\u003e\n\u003cli\u003eSwitching voltage = 24 VDC -15% \/ +20%\u003c\/li\u003e\n\u003cli\u003eNominal output current = 0.1 A\u003c\/li\u003e\n\u003cli\u003eTotal nominal current = 0.4 A\u003c\/li\u003e\n\u003cli\u003eOutput circuit = Sink and\/or source\u003c\/li\u003e\n\u003cli\u003eOutput protection = Thermal shutdown in the event of overcurrent or short circuit, integrated protection for switching inductive loads\u003c\/li\u003e\n\u003cli\u003eDiagnostic status = Output monitoring\u003c\/li\u003e\n\u003cli\u003eLeakage current when the output is switched off = Max. 25 µA\u003c\/li\u003e\n\u003cli\u003eResidual voltage = \u0026lt;0.9 V at 0.1 A nominal current\u003c\/li\u003e\n\u003cli\u003ePeak short-circuit current = \u0026lt;10 A\u003c\/li\u003e\n\u003cli\u003eSwitch-on in the event of overload shutdown or short-circuit shutdown = Approx. 10 ms (depends on the module temperature)\u003c\/li\u003e\n\u003cli\u003eBraking voltage when switching off inductive loads = Switching voltage + 0.6 VDC\u003c\/li\u003e\n\u003cli\u003eAdditional functions = Clock for SSI absolute encoder, linear movement generator\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"Never Used Surplus","offer_id":70984833302781,"sku":"X20DS1319","price":1514.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DS1319.jpg?v=1785724486","url":"https:\/\/shly-plc.com\/products\/x20ds1319","provider":"Lianyou PLC","version":"1.0","type":"link"}