{"product_id":"x20do2649","title":"B\u0026R X20DO2649 | Industrial Automation Component","description":"\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e I\/O systems \u0026gt; X20 System \u0026gt; Digital outputs\u003c\/p\u003e\n\u003cp\u003e2 digital outputs Relay module for 240 VAC \/ 30 VDC 2 change over contacts Single-channel isolated outputs The module is equipped with 2 relay outputs with changeover contacts for 240 VAC \/ 30 VDC.\u003c\/p\u003e\n\u003cp\u003eThe outputs are single-channel isolated.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShort description\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eI\/O module = 2 digital outputs 30 VDC \/ 240 VAC, outputs single-channel isolated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiagnostics\u003c\/li\u003e\n\u003cli\u003eModule run\/error = Yes, using LED status indicator and software\u003c\/li\u003e\n\u003cli\u003eOutputs = Yes, using LED status indicator\u003c\/li\u003e\n\u003cli\u003ePower consumption\u003c\/li\u003e\n\u003cli\u003eBus = 0.45 W\u003c\/li\u003e\n\u003cli\u003eInternal I\/O = -\u003c\/li\u003e\n\u003cli\u003eCertifications\u003c\/li\u003e\n\u003cli\u003eCE = Yes\u003c\/li\u003e\n\u003cli\u003eUKCA = Yes\u003c\/li\u003e\n\u003cli\u003eCRA (Cyber Resilience Act) = In preparation\u003c\/li\u003e\n\u003cli\u003eATEX = Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X\u003c\/li\u003e\n\u003cli\u003eUL = cULus E115267 Industrial control equipment\u003c\/li\u003e\n\u003cli\u003eHazLoc = cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5\u003c\/li\u003e\n\u003cli\u003eDNV = Temperature: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck)\u003c\/li\u003e\n\u003cli\u003eCCS = Yes\u003c\/li\u003e\n\u003cli\u003eLR = ENV1\u003c\/li\u003e\n\u003cli\u003eKR = Yes\u003c\/li\u003e\n\u003cli\u003eABS = Yes\u003c\/li\u003e\n\u003cli\u003eBV = EC33B Temperature: 5 - 55°C Vibration: 4 g EMC: Bridge and open deck\u003c\/li\u003e\n\u003cli\u003eKC = Yes\u003c\/li\u003e\n\u003cli\u003eB\u0026amp;R ID code = 0x20DA\u003c\/li\u003e\n\u003cli\u003eStatus indicators = I\/O function per channel, operating state, module status\u003c\/li\u003e\n\u003cli\u003eAdditional power dissipation caused by actuators (resistive) [W] = +2.5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital outputs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSwitching delay\u003c\/li\u003e\n\u003cli\u003e0 → 1 = ≤10 ms\u003c\/li\u003e\n\u003cli\u003e1 → 0 = ≤10 ms\u003c\/li\u003e\n\u003cli\u003eInsulation voltages\u003c\/li\u003e\n\u003cli\u003eChannel - Bus = Tested at 4000 VAC\u003c\/li\u003e\n\u003cli\u003eChannel - Channel = Tested at 1000 VAC\u003c\/li\u003e\n\u003cli\u003eService life\u003c\/li\u003e\n\u003cli\u003eElectrical = Min. 60 x 10³ ops. (NC) at 6 A Min. 30 x 30³ ops. (NO) at 6 A\u003c\/li\u003e\n\u003cli\u003eMechanical = Min. 10 x 10 6 ops.\u003c\/li\u003e\n\u003cli\u003eSwitching capacity\u003c\/li\u003e\n\u003cli\u003eMinimum = 10 mA \/ 5 VDC\u003c\/li\u003e\n\u003cli\u003eMaximum = 180 W \/ 1500 VA\u003c\/li\u003e\n\u003cli\u003eProtective circuit\u003c\/li\u003e\n\u003cli\u003eExternal\u003c\/li\u003e\n\u003cli\u003eAC = RC combination or VDR\u003c\/li\u003e\n\u003cli\u003eDC = Inverse diode, RC combination or VDR\u003c\/li\u003e\n\u003cli\u003eInternal = None\u003c\/li\u003e\n\u003cli\u003eVariant = Relay \/ Changeover contact Channels are single-channel isolated.\u003c\/li\u003e\n\u003cli\u003eNominal voltage = 30 VDC \/ 240 VAC\u003c\/li\u003e\n\u003cli\u003eMax. voltage = 264 VAC\u003c\/li\u003e\n\u003cli\u003eSwitching voltage = Max. 110 VDC \/ 264 VAC\u003c\/li\u003e\n\u003cli\u003eRated frequency = DC \/ 45 to 63 Hz\u003c\/li\u003e\n\u003cli\u003eNominal output current = 5 A at 30 VDC \/ 5 A at 240 VAC\u003c\/li\u003e\n\u003cli\u003eTotal nominal current = 10 A at 30 VDC \/ 10 A at 240 VAC\u003c\/li\u003e\n\u003cli\u003eActuator power supply = External\u003c\/li\u003e\n\u003cli\u003eInrush current = Max. 6 A (per channel)\u003c\/li\u003e\n\u003cli\u003eContact resistance = 50 mΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical isolation = Channel isolated from channel, bus and I\/O power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMounting orientation\u003c\/li\u003e\n\u003cli\u003eHorizontal = Yes\u003c\/li\u003e\n\u003cli\u003eVertical = Yes\u003c\/li\u003e\n\u003cli\u003eInstallation elevation above sea level\u003c\/li\u003e\n\u003cli\u003e0 to 2000 m = No limitation\u003c\/li\u003e\n\u003cli\u003e\u0026gt;2000 m = Not permitted\u003c\/li\u003e\n\u003cli\u003eDegree of protection per EN 60529 = IP20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature\u003c\/li\u003e\n\u003cli\u003eOperation\u003c\/li\u003e\n\u003cli\u003eHorizontal mounting orientation = -25 to 60°C\u003c\/li\u003e\n\u003cli\u003eVertical mounting orientation = -25 to 50°C\u003c\/li\u003e\n\u003cli\u003eDerating = See section \"Derating\".\u003c\/li\u003e\n\u003cli\u003eStorage = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eTransport = -40 to 85°C\u003c\/li\u003e\n\u003cli\u003eRelative humidity\u003c\/li\u003e\n\u003cli\u003eOperation = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eStorage = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003eTransport = 5 to 95%, non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNote = Order 1x terminal block X20TB12 separately. Order 1x bus module X20BM11 separately.\u003c\/li\u003e\n\u003cli\u003ePitch = 12.5 +0.2 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"B\u0026R","offers":[{"title":"New","offer_id":46160990994685,"sku":"X20DO2649","price":378.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0747\/5665\/3309\/files\/X20DO2649.jpg?v=1785723984","url":"https:\/\/shly-plc.com\/products\/x20do2649","provider":"Lianyou PLC","version":"1.0","type":"link"}